Independent Validation of Sepsis Index for Sepsis Screening in the Emergency Department

被引:16
|
作者
Agnello, Luisa [1 ]
Iacona, Alessandro [2 ]
Maestri, Salvatore [2 ]
Lo Sasso, Bruna [1 ]
Giglio, Rosaria Vincenza [1 ]
Mancuso, Silvia [1 ]
Ciaccio, Anna Maria [3 ]
Vidali, Matteo [4 ]
Ciaccio, Marcello [1 ,2 ]
机构
[1] Univ Palermo, Dept Biomed Neurosci & Adv Diagnost, Inst Clin Biochem Clin Mol Med & Lab Med, I-90127 Palermo, Italy
[2] Univ Hosp P Giaccone, Dept Lab Med, I-90127 Palermo, Italy
[3] Univ Palermo, Unit Clin Biochem, I-90127 Palermo, Italy
[4] Fdn IRCCS Ca Granda Osped Maggiore Policlin, I-20122 Milan, Italy
关键词
sepsis; biomarker; screening; CBC; monocytes; MDW; MMV; MONOCYTE DISTRIBUTION WIDTH; MDW; BIOMARKERS;
D O I
10.3390/diagnostics11071292
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
(1) Background: The early detection of sepsis is still challenging, and there is an urgent need for biomarkers that could identify patients at a high risk of developing it. We recently developed an index, namely the Sepsis Index (SI), based on the combination of two CBC parameters: monocyte distribution width (MDW) and mean monocyte volume (MMV). In this study, we sought to independently validate the performance of SI as a tool for the early detection of patients at a high risk of sepsis in the Emergency Department (ED). (2) Methods: We enrolled all consecutive patients attending the ED with a request of the CBC. MDW and MMV were measured on samples collected in K3-EDTA tubes on the UniCel DxH 900 haematology analyser. SI was calculated based on the MDW and MMV. (3) Results: We enrolled a total of 703 patients stratified into four subgroups according to the Sepsis-2 criteria: control (498), infection (105), SIRS (52) and sepsis (48). The sepsis subgroup displayed the highest MDW (median 27.5, IQR 24.6-32.9) and SI (median 1.15, IQR 1.05-1.29) values. The ROC curve analysis for the prediction of sepsis showed a good and comparable diagnostic accuracy of the MDW and SI. However, the SI displayed an increased specificity, positive predictive value and positive likelihood ratio in comparison to MDW alone. (4) Conclusions: SI improves the diagnostic accuracy of MDW for sepsis screening.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] IMPACT OF THE EMERGENCY DEPARTMENT SEPSIS SCREENING TOOL ON OUTCOMES IN PATIENTS WITH SEPSIS
    Shah, Tanvi
    Rech, Megan
    Sterk, Ethan
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [2] A new tool for sepsis screening in the Emergency Department
    Agnello, Luisa
    Iacona, Alessandro
    Lo Sasso, Bruna
    Scazzone, Concetta
    Pantuso, Michele
    Giglio, Rosaria Vincenza
    Gambino, Caterina Maria
    Ciaccio, Anna Maria
    Bivona, Giulia
    Vidali, Matteo
    Ciaccio, Marcello
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (09) : 1600 - 1605
  • [3] Derivation and internal validation of the screening to enhance prehospital identification of sepsis (SEPSIS) score in adults on arrival at the emergency department
    Michael A. Smyth
    Daniel Gallacher
    Peter K. Kimani
    Mark Ragoo
    Matthew Ward
    Gavin D. Perkins
    [J]. Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 27
  • [4] Derivation and internal validation of the screening to enhance prehospital identification of sepsis (SEPSIS) score in adults on arrival at the emergency department
    Smyth, Michael A.
    Gallacher, Daniel
    Kimani, Peter K.
    Ragoo, Mark
    Ward, Matthew
    Perkins, Gavin D.
    [J]. SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2019, 27 (1):
  • [5] Emergency department sepsis screening tool decreases time to antibiotics in patients with sepsis
    Shah, Tanvi
    Sterk, Ethan
    Rech, Megan A.
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (10): : 1745 - 1748
  • [6] Outcomes of Patients with Sepsis in a Pediatric Emergency Department after Automated Sepsis Screening
    Eisenberg, Matthew A.
    Freiman, Eli
    Capraro, Andrew
    Madden, Kate
    Monuteaux, Michael C.
    Hudgins, Joel
    Harper, Marvin
    [J]. JOURNAL OF PEDIATRICS, 2021, 235 : 239 - +
  • [7] RAISING AWARENESS FOR SEPSIS, SEPSIS SCREENING, EARLY RECOGNITION, AND TREATMENT IN THE EMERGENCY DEPARTMENT
    Walters, Elizabeth
    [J]. JOURNAL OF EMERGENCY NURSING, 2018, 44 (03) : 224 - 227
  • [8] Validation of Sepsis Screening Tool Utilizing StO2 in Emergency Department Patients
    Goerlich, Corbin
    Wade, Charles
    McCarthy, James
    Moore, Laura
    [J]. CRITICAL CARE MEDICINE, 2013, 41 (12)
  • [9] Validation of sepsis screening tool using StO2 in emergency department patients
    Goerlich, Corbin E.
    Wade, Charles E.
    McCarthy, James J.
    Holcomb, John B.
    Moore, Laura J.
    [J]. JOURNAL OF SURGICAL RESEARCH, 2014, 190 (01) : 270 - 275
  • [10] Challenges and Opportunities for Emergency Department Sepsis Screening at Triage
    Michael R. Filbin
    Jill E. Thorsen
    James Lynch
    Trent D. Gillingham
    Corey L. Pasakarnis
    Roberta Capp
    Nathan I. Shapiro
    Theodore Mooncai
    Peter C. Hou
    Thomas Heldt
    Andrew T. Reisner
    [J]. Scientific Reports, 8