Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments

被引:76
|
作者
Zavanelli, RA
Henriques, GEP
Ferreira, I
Rollo, JMDD
机构
[1] Univ Western Sao Paulo, Presidente Prudente Dent Sch, Dept Restorat Dent, Sao Paulo, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Prosthodont, Sao Paulo, Brazil
[3] Sao Paulo State Univ, Sao Carlos Sch Engn, Dept Dent Mat, Sao Paulo, Brazil
[4] Univ Estadual Campinas, Mech Engn Sch, Dept Dent Mat, Sao Paulo, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2000年 / 84卷 / 03期
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1067/mpr.2000.108758
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Removable partial dentures are affected by fatigue because of the cyclic mechanism of the masticatory system ansi frequent insertion and removal. Titanium and its alloys have been used in the manufacture of denture frameworks; however, preventive agents with fluorides are thought to attack titanium alloy surfaces. Purpose. This study evaluated, compared, analyzed the corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloy in different storage environments. Material and methods. For each metal, 33 dumbbell rods, 2.3 mm in diameter at the central segment, were cast in the Rematitan system. Corrosion-fatigue strength test was carried out through a universal testing machine with a load 30% lon er than the 0.2% offset yield strength and a combined influence of different: environments: in air at room temperature, with synthetic saliva, and with fluoride synthetic saliva. After failure, the number of cycles were recorded, and fracture surfaces were examined with on SEM. Results. ANOVA and Tukey's multiple comparison rest indicated that Ti-6Al-4V alloy achieved 21,269 cycles (SD = 8,355) against 19,157 cycles (SD = 3,624) for the commercially purr Ti. There were no significant differences between either metal in the corrosion-fatigue life for dry specimens, but when the solutions were present, the fatigue life was significantly reduced, probably because of the product-ion of corrosion pits caused by superficial reactions.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 50 条
  • [1] Corrosion-fatigue of laser-repaired commercially pure titanium and Ti-6Al-4V alloy under different test environments
    Zavanelli, RA
    Guilherme, AS
    Pessanha-Henriques, GE
    Nóbilo, MAD
    Mesquita, MF
    JOURNAL OF ORAL REHABILITATION, 2004, 31 (10) : 1029 - 1034
  • [2] A study of the microstructure and hardness of two titanium alloys: Commercially pure and Ti-6Al-4V
    Poondla, N.
    Srivatsan, T. S.
    Patnaik, A.
    Petraroli, M.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2009, 486 (1-2) : 162 - 167
  • [3] Influence of oxidative nanopatterning and anodization on the fatigue resistance of commercially pure titanium and Ti-6Al-4V
    Ketabchi, Amirhossein
    Weck, Arnaud
    Variola, Fabio
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (03) : 563 - 571
  • [4] Ion nitriding of a commercially pure titanium alloy and of a Ti-6Al-4V
    Fare, S.
    Lecis, N.
    Vedani, M.
    Vimercati, G.
    Silipigni, A.
    Corti, D.
    Favoino, P.
    METALLURGIA ITALIANA, 2010, (06): : 13 - 18
  • [5] Hypervelocity Impact Response of Ti-6Al-4V and Commercially Pure Titanium
    Iyer, Kaushik A.
    Poormon, Kevin L.
    Deacon, Ryan M.
    Mehoke, Douglas S.
    Swaminathan, P. K.
    Brown, Robert C.
    PROCEEDINGS OF THE 12TH HYPERVELOCITY IMPACT SYMPOSIUM, 2013, 58 : 127 - 137
  • [6] Effect of thermal treatments on tensile strength of commercially cast pure titanium and Ti-6Al-4V alloys
    Sicknan Soares da Rocha
    Gelson Luis Adabo
    Luis Geraldo Vaz
    Guilherme Elias Pessanha Henriques
    Journal of Materials Science: Materials in Medicine, 2005, 16 : 759 - 766
  • [7] Effect of thermal treatments on tensile strength of commercially cast pure titanium and Ti-6Al-4V alloys
    Da Rocha, SS
    Adabo, GL
    Vaz, LG
    Henriques, GEP
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (08) : 759 - 766
  • [8] Effect of microstructure on the fatigue properties of Ti-6Al-4V titanium alloys
    Wu, G. Q.
    Shi, C. L.
    Sha, W.
    Sha, A. X.
    Jiang, H. R.
    MATERIALS & DESIGN, 2013, 46 : 668 - 674
  • [9] Corrosion and corrosion-fatigue behavior of cp-Ti and Ti-6Al-4V laser-marked biomaterials
    Gil, F. J.
    Delgado, L.
    Espinar, E.
    Llamas, J. M.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (04) : 885 - 890
  • [10] DEFORMATION RESISTANCE IN PLATE ROLLING OF COMMERCIALLY PURE TITANIUM AND TI-6AL-4V ALLOY
    YAMAMOTO, S
    OUCHI, C
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 72 (06): : 595 - 602