Test of a Large Volume Calorimeter in KEPRI Tritium Laboratory

被引:0
|
作者
Song, K. M. [1 ]
Ko, B. W. [1 ]
Lee, K. W. [1 ]
Sohn, S. H. [1 ]
机构
[1] Korea Elect Power Res Inst, Nucl Power Lab, Taejon, South Korea
来源
2009 23RD IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING | 2009年
关键词
tritium; calorimeter; tritium accounts; precision;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A tritium assaying and dispensing system has been designed and is being constructed in KEPTL (Korea Electric Power Research Institute, Tritium Laboratory). This facility will be used to supply tritium from WTRF (Wolsong Tritium Removal Facility) to customers for industrial uses, R&D application, ITER operation and other purposes. In order to account the tritium amount loaded in and out this facility, KEPTL purchased a large volume calorimeter from Setaram. This calorimeter is integrated in a dedicated room of the KEPTL in 2008 and the site acceptance tests are completed. The KEPTL calorimeter is a twin cell type and its measuring range is from 0.01 gram of tritium to 60 gram of tritium. The tritium storage beds loaded into the measuring cell of the calorimeter reach a maximum size of 200 mm in diameter and 570 mm in height. The performance test has been successfully completed with a Joule effect cell simulating tritium decay heat. It is demonstrated that the precision of the calorimeter is measured to be less than 0.28% at 50 mW and 0.13% at 10W. Relative error on real tritium test is measured to be 0.06% on 37 TBq of tritium.
引用
收藏
页码:509 / 512
页数:4
相关论文
共 50 条
  • [1] Test of a Large-Volume Calorimeter in KEPRI Tritium Laboratory
    Song, Kyu-Min
    Ko, Byung-Wook
    Lee, Kei-Woo
    Sohn, Soon-Hwan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2010, 38 (03) : 295 - 299
  • [2] Evaluation of a newly developed tritium calorimeter at Los Alamos National Laboratory
    West, Diana S.
    Frame, Kandy J.
    Thompson, Julia
    Ticknor, Lawrence O.
    FUSION SCIENCE AND TECHNOLOGY, 2008, 54 (01) : 178 - 181
  • [3] LABORATORY CALORIMETER FOR MEASURING LOW VOLUME COMBUSTION HEATS OF GASES
    FARZANE, NG
    ILYASOV, LV
    INDUSTRIAL LABORATORY, 1969, 35 (09): : 1365 - &
  • [4] Convolutional denoising for large-volume Seebeck calorimeter
    Zhang, Wu-Shou
    THERMOCHIMICA ACTA, 2024, 736
  • [5] Tritium dynamics in large fish - a model test
    Melintescu, A.
    Galeriu, D.
    Kim, S. B.
    RADIOPROTECTION, 2011, 46 (06) : S431 - S436
  • [6] An isothermal heat flow calorimeter for large-volume applications
    Vratislav Tydlitát
    Jan Zákoutský
    Robert Černý
    Journal of Thermal Analysis and Calorimetry, 2012, 110 : 1021 - 1027
  • [7] An isothermal heat flow calorimeter for large-volume applications
    Tydlitat, Vratislav
    Zakoutsky, Jan
    Cerny, Robert
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2012, 110 (02) : 1021 - 1027
  • [8] DESIGN AND PERFORMANCE TESTING OF A TRITIUM CALORIMETER
    THORNTON, MI
    VASSALLO, G
    MILLER, J
    MASON, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 363 (03): : 598 - 603
  • [9] A large scale cryopanel test arrangement for tritium pumping
    Day, C
    Brennan, D
    Jensen, HS
    Mack, A
    FUSION ENGINEERING AND DESIGN, 2003, 69 (1-4) : 97 - 102
  • [10] A TEST OF LARGE BAF2 CRYSTALS AS AN ELECTROMAGNETIC CALORIMETER
    GRAHAM, G
    YAMAMOTO, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (2-3): : 240 - 246