Construction and analysis of finite element model of defected articular cartilage

被引:4
|
作者
Lin, Yuan [1 ]
Qin, Jizheng [1 ]
Zhao, Honghai [1 ]
Xia, Chun [1 ]
机构
[1] Xiamen Univ, Dept Joint Surg & Sports Med, Zhongshan Hosp, Xiamen 361004, Fujian, Peoples R China
关键词
Articular cartilage; Finite element simulation; Fluid flow; MRI; Permeability; REPAIR; TISSUE; KNEE;
D O I
10.1016/j.sjbs.2019.11.020
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In order to construct a finite element model of defected articular cartilage, the mechanical behavior and degeneration of articular cartilage after injury were studied. The simplified analytical models of normal and defected articular cartilage and finite element models were established, respectively. Firstly, the analytical solution model and finite element model of hollow defect were constructed by using the elasticity theory of multi-hollow medium. Then, the analytical results of each model were calculated and programmed. The software MATLAB was used for programming calculation. Finally, a finite element solid model of defected articular cartilage was established by using human femoral joint. The solid model was analyzed and calculated by magnetic resonance imaging (MRI). The results showed that when the radius of articular cartilage defect r = 0, i.e. there was no defect in articular cartilage, the internal pore pressure of the defect cartilage was the largest, and its pore pressure value was 27 x 10(3)pa. When the depth of articular cartilage defect r = 0, i.e. there was no defect in articular cartilage, the internal pore pressure of the defect cartilage was the largest, and its pore pressure value was 27.5 x 10(3)pa, and it gradually decreased towards the outer boundary of cartilage. When the surface of femoral cartilage began to defect, with the increase of the depth of the defect (from shallow to deep), the maximum pore pressure in the defect cartilage gradually decreased, but the speed is slowly. With the increase of the defect radius, that is, the area of the defect, the maximum pore pressure in the defect cartilage gradually decreased. When there was no defect of articular cartilage, the internal pore pressure of the defect cartilage was the maximum, the value of pore pressure was 8.7 x 10(3)pa, the value of pore pressure at the contact position of femoral cartilage was the largest, and it gradually decreased towards the outer boundary of cartilage. At the same location, the pore pressure of normal cartilage was significantly higher than that of defected cartilage. With the change of defect location, the pore pressure was reduced accordingly. Moreover, when the defect position moved from the outside to the inside, the corresponding pore pressure value was decreased gradually. To sum up, the finite element model of defected articular cartilage based on porous elasticity theory has better calculation ability, which proves the validity of the finite element software, and provides a strong basis for future model establishment and clinical treatment of articular cartilage. (C) 2019 The Author(s). Published by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:556 / 560
页数:5
相关论文
共 50 条
  • [1] Finite element formulation of biphasic poroviscoelastic model for articular cartilage
    Suh, JK
    Bai, S
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (02): : 195 - 201
  • [2] Finite element modeling of articular cartilage
    van Turnhout, M.
    Spoor, K.
    Van Leeuwen, J.
    [J]. COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2006, 143 (04): : S95 - S95
  • [3] Finite Element Analysis of Articular Cartilage Model Considering the Configuration and Biphasic Property of the Tissue
    Hosoda, N.
    Sakai, N.
    Sawae, Y.
    Murakami, T.
    [J]. 13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1883 - +
  • [4] Utilization of Finite Element Analysis for Articular Cartilage Tissue Engineering
    Hassan, Chaudhry R.
    Qin, Yi-Xian
    Komatsu, David E.
    Uddin, Sardar M. Z.
    [J]. MATERIALS, 2019, 12 (20)
  • [5] Modelling of articular cartilage containing chondrocytes and finite element analysis for articular cartilage and chondrocytes under compression
    Ihara, Maki
    Murakami, Teruo
    Sawae, Yoshinori
    [J]. Nippon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2003, 69 (02): : 487 - 493
  • [6] FINITE ELEMENT ANALYSIS OF FULL-LAYER REPAIR BASED ON IMPROVED ARTICULAR CARTILAGE MODEL
    Wang, Monan
    Ji, Yuanxin
    Wang, Jian
    Jing, Juntong
    [J]. JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2019, 19 (08)
  • [7] A finite element analysis methodology for representing the articular cartilage functional structure
    Olsen, S.
    Oloyede, A.
    [J]. Computer Methods in Biomechanics and Biomedical Engineering, 2002, 5 (06) : 377 - 386
  • [9] Characterization of articular cartilage by combining microscopic analysis with a fibril-reinforced finite-element model
    Julkunen, Petro
    Kiviranta, Panu
    Wilson, Wouter
    Jurvelin, Jukka S.
    Korhonen, Rarni K.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (08) : 1862 - 1870
  • [10] The finite element analysis of articular cartilage fiber-reinforced composite model under rolling load
    Qin XiaofengLiu HaiyingYe JinduoZhang ChunqiuSchool of Mechanical EngineeringTianjin University of TechnologyTianjin
    [J]. 医用生物力学., 2009, 24(S1) (S1)