Equivalence Randomized Controlled Trial of Bioresorbable Versus Titanium Miniplates in Treatment of Mandibular Fracture: A Pilot Study

被引:28
|
作者
Bhatt, Krushna
Roychoudhury, Ajoy [1 ]
Bhutia, Ongkila [1 ]
Trikha, Anjan [2 ]
Seith, Ashu [3 ]
Pandey, Ravinder Mohan [4 ]
机构
[1] All India Inst Med Sci, Dept Oral & Maxillofacial Surg, CDER, New Delhi 110029, India
[2] All India Inst Med Sci, Dept Anesthesia & Intens Care, New Delhi 110029, India
[3] All India Inst Med Sci, Dept Radio Diag, New Delhi 110029, India
[4] All India Inst Med Sci, Dept Biostat, New Delhi 110029, India
关键词
ANGLE FRACTURES; PLATE OSTEOSYNTHESIS; ORTHOGNATHIC SURGERY; FACIAL FRACTURES; BONE PLATES; FIXATION; STABILITY; IMPLANTS; REMOVAL; SCREWS;
D O I
10.1016/j.joms.2009.09.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The present study was undertaken to test bioresorbable fixation versus titanium for equivalence in terms of clinical union and complications using the American Association of Oral and Maxillofacial Surgeons parameters of care. The study design was a randomized, controlled, equivalence trial. Materials and Methods: A total of 40 patients were enrolled and allocated to the titanium group and bioresorbable group using a computerized randomization table. All were plated using standard plating principles. In the bioresorbable group, 2 weeks of maxillomandibular fixation was also used. Evaluation of the study endpoint was done at 8 weeks postoperatively. For statistical analysis, the upper limit of the 95% confidence interval was calculated for failure to achieve the primary outcome variable and compared with the maximal clinically acceptable difference between the standard and test modalities in the failure to achieve clinical union (5). 5 was predetermined as 2%. The other complications were tested for significance using Fisher's exact test. Results: Of the 40 patients, 21 were in the titanium group and 19 were in the bioresorbable group, with 20 men and 1 woman in the titanium group and 18 men and 1 woman in the bioresorbable group. The mean age was 28.7 years in the titanium group and 26.6 years in the bioresorbable group. In the titanium group, the complications noted were nonunion in 0%, malocclusion in 7.7%, continued postoperative swelling in 0%, chronic pain in 2%, infection in 5.2%, an inability to chew hard food after 8 weeks in 7.7%, the need for alternative treatment in 0%, and the need for reoperation in 31%. In the bioresorbable group, the complications were nonunion in 4.17%, malocclusion in 11.1%, swelling in 8.3%, chronic pain in 37.5%, infection in 0%, an inability to chew hard food in 11.1%, the need for alternative treatment in 11.1%, and need for reoperation for plate removal in 0%. Conclusions: The small sample size did not allow any meaningful conclusion to be drawn from the present study in terms of the primary question of achieving union. Both groups matched in outcomes when evaluated only on a clinical basis. The avoidance of repeat surgery for plate removal is a definite advantage of using resorbable plates. However, the results are inconclusive in favor of any particular plating system. (c) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:1842-1848, 2010
引用
收藏
页码:1842 / 1848
页数:7
相关论文
共 50 条
  • [1] Comparative study between patient specific titanium plates versus conventional miniplates for treatment of mandibular fractures: Randomized clinical trial
    Taalab, Dina Adel
    Shehab, Ahmed Farid
    Atef, Mohammed
    Shehab, Mohamed Farid
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2023, 51 (04) : 217 - 223
  • [2] Rigid internal fixation with titanium versus bioresorbable miniplates in the repair of mandibular fractures in rabbits
    Hochuli-Vieira, E
    Gabrielli, MA
    Pereira-Filho, VA
    Gabrielli, MFR
    Padilha, JG
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (02) : 167 - 173
  • [3] Titanium miniplates in mandibular fracture repair in dogs and cats: study of 6 cases
    Gomes, Cristiano
    Gouvea, Aline Silva
    Alievi, Marcelo Meller
    Contesini, Emerson Antonio
    Pippi, Ney Luis
    CIENCIA RURAL, 2010, 40 (05): : 1128 - 1133
  • [4] Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture
    Mohsin Khan
    Ashish Vishal
    Tanya Kumar
    Dharmendra Kumar Khaitan
    Chandan Sinha
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2020, 72 : 363 - 369
  • [5] Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture
    Khan, Mohsin
    Vishal
    Kumar, Ashish
    Khaitan, Tanya
    Sinha, Dharmendra Kumar
    Kumar, Chandan
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2020, 72 (03) : 363 - 369
  • [6] A retrospective comparative study of mandibular fracture treatment with internal fixation using reconstruction plate versus miniplates
    Sukegawa, Shintaro
    Kanno, Takahiro
    Masui, Masanori
    Sukegawa-Takahashi, Yuka
    Kishimoto, Tsukasa
    Sato, Ai
    Furuki, Yoshihiko
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (08) : 1175 - 1180
  • [7] A Comparative Study of 3-Dimensional Titanium Versus 2-Dimensional Titanium Miniplates for Open Reduction and Fixation of Mandibular Parasymphysis Fracture
    Mittal Y.
    Varghese K.G.
    Mohan S.
    Jayakumar N.
    Chhag S.
    Journal of Maxillofacial and Oral Surgery, 2016, 15 (1) : 93 - 98
  • [8] Assessment of CAD/CAM Customized V Pattern Plate Versus Standard Miniplates Fixation in Mandibular Angle Fracture (Randomized Clinical Trial)
    Hiba Obad Saleh
    Basma Gamal Moussa
    Khaled Amr Salah Eddin
    Samer Abduljabar Noman
    Ahmed Mohammed Salah
    Journal of Maxillofacial and Oral Surgery, 2023, 22 : 995 - 1005
  • [9] Assessment of CAD/CAM Customized V Pattern Plate Versus Standard Miniplates Fixation in Mandibular Angle Fracture (Randomized Clinical Trial)
    Saleh, Hiba Obad
    Moussa, Basma Gamal
    Salah Eddin, Khaled Amr
    Noman, Samer Abduljabar
    Salah, Ahmed Mohammed
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (04): : 995 - 1005
  • [10] PILOT RANDOMIZED CONTROLLED TRIAL OF SPINAL VERSUS GENERAL ANESTHESIA FOR HIP FRACTURE SURGERY
    Neuman, Mark D.
    Mehta, Samir
    Bannister, Evan R.
    Hesketh, Patrick J.
    Horan, Annamarie D.
    Elkassabany, Nabil M.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2016, 64 (12) : 2604 - 2606