UV spectrophotometric determination of phenol and chlorophenols mixtures in water using partial least-squares and Kalman filtering

被引:0
|
作者
Kostrhounová-Stepánková, R
Jancár, L
Sommer, L
机构
[1] Masaryk Univ, Fac Sci, RECETOX, Brno 62500, Czech Republic
[2] Masaryk Univ, Fac Educ, Dept Chem, Brno 60300, Czech Republic
[3] Brno Univ Technol, Fac Chem, Inst Environm Chem & Technol, Brno 61200, Czech Republic
来源
CHEMICKE LISTY | 2003年 / 97卷 / 05期
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The UV spectrophotometric determination of phenol and chlorophenols in mixtures was performed by using multivariate calibration with partial least-squares in drinking and surface waters. Absorbance and their first derivatives were evaluated for mixtures of phenol, 2-chloro-, 2,6-dichloro- and 2,3,6-trichlorophenol or phenol, 2-, 3- and 4-chlorophenol with satisfactory prediction of errors of results in the 10-100 mumol.1(-1) range for drinking and surface waters in the presence of 1.0 mol.1(-1) NaOH and greater than or equal to 1.0 mmol.1(-1) EDTA using a calibration set with 17 standard solutions (full statistic design) and 24 wavelengths. Humic acids interfere and their influence must be eliminated by previous addition into calibration solutions. Kalman filtering gives more accurate results for samples containing monochlorophenols and phenol with very similar absorption spectra.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [1] SPECTROPHOTOMETRIC DETERMINATION OF PHARMACEUTICAL DOSAGES BY PARTIAL LEAST-SQUARES CALIBRATION
    BLANCO, M
    COELLO, J
    GONZALEZ, F
    ITURRIAGA, H
    MASPOCH, S
    TOMAS, X
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (04) : 509 - 514
  • [2] UV-spectrophotometric determination of ketoprofen and paraben in a gel preparation by partial least-squares calibration
    M. Blanco
    J. Coello
    H. Iturriaga
    S. Maspoch
    S. Alaoui-Ismaili
    Fresenius' Journal of Analytical Chemistry, 1997, 357 : 967 - 972
  • [3] UV-spectrophotometric determination of ketoprofen and paraben in a gel preparation by partial least-squares calibration
    Blanco, M
    Coello, J
    Iturriaga, H
    Maspoch, S
    AlaouiIsmaili, S
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (07): : 967 - 972
  • [4] Spectrophotometric analysis of α- and β-naphthol mixtures applying partial least-squares method
    Revilla, AL
    Vargas, G
    Havel, J
    CHEMICAL PAPERS-CHEMICKE ZVESTI, 1999, 53 (01): : 34 - 39
  • [5] On the equivalence of Kalman filtering and least-squares estimation
    Mysen, E.
    JOURNAL OF GEODESY, 2017, 91 (01) : 41 - 52
  • [6] On the equivalence of Kalman filtering and least-squares estimation
    E. Mysen
    Journal of Geodesy, 2017, 91 : 41 - 52
  • [7] USE OF THE METHOD OF LEAST-SQUARES IN THE SPECTROPHOTOMETRIC DETERMINATION OF THE CONCENTRATION OF A MIXTURES COMPONENTS
    DUBASOV, YV
    KHRAMOV, NN
    SOVIET RADIOCHEMISTRY, 1985, 27 (03): : 352 - 354
  • [8] Simultaneous spectrophotometric determination of iron, nickel, and vanadium using partial least-squares regression
    Afshar-Ebrahimi, A
    Kompany-Zareh, M
    Massoumi, A
    CHEMIA ANALITYCZNA, 2004, 49 (03): : 413 - 420
  • [9] A FURTHER NOTE ON FLEXIBLE LEAST-SQUARES AND KALMAN FILTERING
    KALABA, R
    TESFATSION, L
    JOURNAL OF ECONOMIC DYNAMICS & CONTROL, 1990, 14 (01): : 183 - 185
  • [10] Erratum to: On the equivalence of Kalman filtering and least-squares estimation
    E. Mysen
    Journal of Geodesy, 2017, 91 : 463 - 463