Luminance and contrast performance of liquid crystal displays for mammographic applications

被引:5
|
作者
Samei, E
Wright, SL
机构
[1] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Dept Phys, Durham, NC 27710 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
[4] IBM Corp, Thomas J Watson Res Ctr, Yorktown Hts, NY 10598 USA
关键词
display quality; image quality; PACS; medical imaging; DICOM; TG18; cathode ray tube (CRT); liquid crystal display (LCD); ambient lighting; luminance;
D O I
10.1177/153303460400300503
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Liquid crystal displays (LCDs) are gradually replacing cathode-ray tubes (CRTs) as the primary means of electronic display of digital radiographs. The transition from CRT to LCD is fueled by advantages of the LCD technology such as enhanced maximum luminance and smaller form factor. This transition is expected to extend to digital mammography as well. The purpose of this study was to report the on-axis luminance and contrast performance of five medical-grade LCDs in terms of compliance with the DICOM grayscale display function (GSDF) and AAPM TG18 guidelines. The display devices included two 3 Mpx monochrome LCDs (Planar Dome C3, and NDS 20.8" Nova), two 5 Mpx monochrome LCDs (NDS 21.3" Nova, and Totoku ME511L), and one 9 Mpx color LCD (IBM T221). The on-axis luminance values were measured at all 8-bit driving levels using the TG18-LN test patterns and a baffled luminance meter and the results averaged. The luminance data were analyzed according to the AAPM TG18 methodology. The measured L-min, L-max, mean DeltaJND/Deltap, and maximum local deviation in DeltaJND/Deltap from GSDF, kappa(256), ranged within 0.43-0.87 cd/m(2), 263-715 cd/m(2), 2.15-2.72, and 0.79-1.46 intervals, respectively. While the values varied notably between different devices, all devices conformed to the TG18 criteria for primary class displays in terms of on-axis luminance response, and thus judged suitable for mammographic applications from on-axis luminance standpoint. Notwithstanding the findings, other factors such as matrix size, angular response, and color functionality should further be taken into consideration.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 50 条
  • [1] Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays
    Badano, A
    Flynn, MJ
    Martin, S
    Kanicki, J
    MEDICAL PHYSICS, 2003, 30 (10) : 2602 - 2613
  • [2] Photographic measurement of the effects of viewing angle on the luminance and contrast of liquid crystal displays
    Fetterly, KA
    Samei, E
    MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2, 2005, 5744 : 263 - 270
  • [3] Angular dependence of the luminance and contrast in medical imaging monochrome active matrix liquid crystal displays
    Badano, A
    Flynn, MJ
    Martin, S
    Kanicki, J
    RADIOLOGY, 2001, 221 : 377 - 377
  • [4] Required luminance of black level on liquid crystal displays
    Faculty of Science and Technology, Seikei University, 3-3-1, Kichijoji-kitamachi, Musashino-shi, Tokyo 180-8633, Japan
    不详
    Kyokai Joho Imeji Zasshi, 2009, 3 (349-354):
  • [5] A study on concurrent luminance and temporal measurements in liquid crystal displays
    Pan, Ding-Hsiang
    AD'07: Proceedings of Asia Display 2007, Vols 1 and 2, 2007, : 931 - 934
  • [6] Nanoimprint Applications for Liquid Crystal Displays
    Kikuchi, Hiroshi
    Sato, Hiroto
    Fujikake, Hideo
    Sato, Fumio
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 442 - +
  • [7] Effective luminance deterioration of medical liquid crystal displays in clinical use
    Takahashi K.
    Awamoto S.
    Takarabe S.
    Ogawa K.
    Nakamura Y.
    Radiological Physics and Technology, 2017, 10 (3) : 382 - 386
  • [8] Reflectance and contrast measurements of reflective liquid crystal displays
    Kubota, S
    DISPLAYS, 1997, 18 (02) : 79 - 83
  • [9] Perceived contrast on displays with different luminance ranges
    Sund, Patrik
    MEDICAL PHYSICS, 2022, 49 (04) : 2270 - 2278
  • [10] The apparent luminance contrast in impossible shadow displays
    Soranzo, A.
    Galmonte, A. C. G.
    Agostini, T. A.
    PERCEPTION, 2006, 35 : 227 - 228