Fiber deflection probing method based on micro focal-length collimation

被引:13
|
作者
Tan, Jiubin [1 ]
Wang, Fei [1 ]
Cui, Jiwen [1 ]
机构
[1] Harbin Inst Technol, Ultraprecis Optoelect Instrument Engn Ctr, Harbin 150080, Peoples R China
来源
OPTICS EXPRESS | 2010年 / 18卷 / 03期
基金
中国国家自然科学基金;
关键词
D O I
10.1364/OE.18.002925
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In order to improve the low displacement sensitivity in sensing the 2D deflection of a fiber probe used for measurement of micro cavities with high aspect ratio, a fiber stem with a ball mounted on its end is used as a probe and a small segment of it is used as a cylindrical lens to collimate a point light source and image it to a camera. The deflection of the fiber stem can be inferred from the change in image acquired by the camera with ultrahigh displacement sensitivities of 10,000 and 20,000 in two dimensions using a fiber stem of 44 mu m in diameter, and the corresponding resolutions are better than 1 nm and 3 nm respectively. (C) 2010 Optical Society of America
引用
收藏
页码:2925 / 2933
页数:9
相关论文
共 50 条
  • [1] A 3D fiber probe based on orthogonal micro focal-length collimation and fiber Bragg grating
    Cui, Jiwen
    Li, Junying
    Feng, Kunpeng
    Tan, Jiubin
    Zhang, Jian
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (07)
  • [2] Three-dimensional fiber probe based on orthogonal micro focal-length collimation for the measurement of micro parts
    Cui, Jiwen
    Li, Junying
    Feng, Kunpeng
    Tan, Jiubin
    OPTICS EXPRESS, 2015, 23 (20): : 26386 - 26398
  • [3] Three-dimensional fiber probe based on micro focal-length collimation and a fiber Bragg grating for the measurement of micro parts
    Cui, Jiwen
    Li, Junying
    Feng, Kunpeng
    Tan, Jiubin
    OPTICS LETTERS, 2015, 40 (14) : 3348 - 3351
  • [4] Brain SPECT with short focal-length cone-beam collimation
    Park, MA
    Moore, SC
    Kijewski, MF
    MEDICAL PHYSICS, 2005, 32 (07) : 2236 - 2244
  • [5] Brain SPECT with short focal-length cone-beam collimation.
    Park, MA
    Moore, SC
    Kijewski, MF
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 8P - 8P
  • [6] Spherical aberration compensation method for long focal-length measurement based on Talbot interferometry
    Luo, Yupeng
    Huang, Xiao
    Bai, Jian
    Du, Juan
    Liu, Qun
    Luo, Yujie
    Luo, Jia
    PACIFIC RIM LASER DAMAGE 2017-OPTICAL MATERIALS FOR HIGH-POWER LASERS, 2017, 10339
  • [7] Texture Aware Learning-based Image Fusion Method for Fixed Focal-length Cameras
    Ma Haoyu
    Xu Zhihai
    Feng Huajun
    Li Qi
    Chen Yueting
    Huang Jiazi
    AOPC 2017: OPTICAL SENSING AND IMAGING TECHNOLOGY AND APPLICATIONS, 2017, 10462
  • [8] An inversion formula for the exponential Radon transform in spatial domain with variable focal-length fan-beam collimation geometry
    Wen, JH
    Liang, ZR
    MEDICAL PHYSICS, 2006, 33 (03) : 792 - 798
  • [9] Region-Based Adaptive Automatic Focal-Length Estimation Method for Fisheye-Lens Distortion Correction
    Kim, Hyungtae
    Kim, Daehee
    Paik, Joonki
    2014 International Conference on Electronics, Information and Communications (ICEIC), 2014,
  • [10] Array of lenses with individually tunable focal-length based on transparent ion-implanted EAPs
    Niklaus, Muhamed
    Rosset, Samuel
    Shea, Herbert
    ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD) 2010, 2010, 7642