Micro-calorimetric sensor for vapor phase explosive detection with optimized heat profile

被引:15
|
作者
Greve, A. [1 ]
Olsen, J. [1 ]
Privorotskaya, N. [2 ]
Senesac, L. [3 ]
Thundat, T. [3 ]
King, W. P. [2 ]
Boisen, A. [1 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Univ Illinois, Dept Mech Sci & Engn, Urbana, IL 61801 USA
[3] Oak Ridge Natl Lab, Div Life Sci, Oak Ridge, TN USA
关键词
Calorimetry; Explosive detection; Micro-heater;
D O I
10.1016/j.mee.2009.12.069
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A heater design, used in a micro-calorimetric sensor, has been optimized for temperature uniformity in order to increase the sensitivity and reliability of detection of trace amounts of explosives. In this abstract the design, fabrication and characterization is described. The performance of the novel heater design is characterized by measuring the temperature coefficient of resistivity (TCR) values and by mapping the temperature distribution using Raman spectroscopy. The new heater design is seen to have increased the temperature uniformity by a factor of 2.3. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:696 / 698
页数:3
相关论文
共 50 条
  • [1] Micro-Calorimetric Sensor for Vapour Phase Explosive Detection with Optimized Heat Profile
    Greve, A.
    Olsen, J. K.
    Privorotskaya, N.
    Senesac, L.
    Thundat, T.
    King, W. P.
    Boisen, A.
    [J]. 2009 IEEE SENSORS, VOLS 1-3, 2009, : 724 - +
  • [2] Micro Calorimetric Sensor for Trace Explosive Particle Detection
    Olsen, Jesper K.
    Greve, Anders
    Privorotskaya, N.
    Senesac, L.
    Thundat, T.
    King, W. P.
    Boisen, A.
    [J]. MICRO- AND NANOTECHNOLOGY SENSORS, SYSTEMS, AND APPLICATIONS II, 2010, 7679
  • [3] MICRO-CALORIMETRIC MEASUREMENT OF PRODUCTION HEAT IN ISOLATED HUMAN ADIPOCYTES
    MONTI, M
    NILSSONEHLE, P
    SORBRIS, R
    WADSO, I
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1980, 40 (06): : 581 - 587
  • [4] ALD nano-catalyst for micro-calorimetric detection of hydrocarbons
    Biro, Ferenc
    Ducso, Csaba
    Radnoczi, Gyorgy Z.
    Baji, Zsofia
    Takacs, Mate
    Barsony, Istvan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 617 - 625
  • [5] MICRO-CALORIMETRIC DETERMINATION OF THE HEAT-CAPACITY OF ILL-DEFINED MATERIAL
    LAMPRECHT, I
    SCHAARSCHMIDT, B
    [J]. THERMOCHIMICA ACTA, 1980, 36 (02) : 169 - 172
  • [6] REINVESTIGATION OF HEAT-PRODUCTION OF THE CONTRACTING MUSCLE BY THE MICRO-CALORIMETRIC METHOD - THE PROBLEM OF THE HEAT OF SHORTENING
    LORINCZI, D
    [J]. STUDIA BIOPHYSICA, 1982, 89 (02): : 81 - 97
  • [7] MICRO-CALORIMETRIC STUDY OF MARINE-BACTERIA METABOLISM - DETECTION OF RHYTHMICAL PROCESSES
    WAGENSBERG, J
    CASTEL, C
    TORRA, V
    RODELLAR, J
    VALLESPINOS, F
    [J]. INVESTIGACION PESQUERA, 1978, 42 (01): : 179 - 188
  • [8] A NEW APPROACH TO DETECTION OF ANTIGEN-ANTIBODY COMPLEXES BY MICRO-CALORIMETRIC MEASUREMENTS OF HEAT-PRODUCTION IN BLOOD-CELLS
    MONTI, M
    FALDT, R
    ANKERST, J
    WADSO, I
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 37 (01) : 29 - 37
  • [9] MICRO-CALORIMETRIC MEASUREMENTS OF HEAT-PRODUCTION IN PLATELETS OF PATIENTS WITH PROSTHETIC HEART-VALVES
    MONTI, M
    FAGHER, B
    [J]. CLINICA CHIMICA ACTA, 1980, 102 (01) : 83 - 89
  • [10] A colorimetric receptor combined with a microcantilever sensor for explosive vapor detection
    Zhu, Weibin
    Park, Jung Su
    Sessler, Jonathan L.
    Gaitas, Angelo