The diagnostic accuracy of high b-value diffusion- and T2-weighted imaging for the detection of prostate cancer: a meta-analysis

被引:12
|
作者
Syer, Tom J. [1 ]
Godley, Keith C. [2 ]
Cameron, Donnie [1 ]
Malcolm, Paul N. [2 ]
机构
[1] Univ East Anglia, Norwich Med Sch, Fac Med & Hlth Sci, Norwich NR4 7TJ, Norfolk, England
[2] Norfolk & Norwich Univ NHS Fdn Trust, Dept Radiol, Colney Lane, Norwich NR4 7UY, Norfolk, England
关键词
Prostate cancer; Diffusion-weighted imaging; T-2-weighted imaging; b-value; Meta-analysis; WEIGHTED MRI; TRANSITION-ZONE; 3; T; MULTIPARAMETRIC MRI; TUMOR-DETECTION; COEFFICIENT MAP; CLINICAL-VALUE; DATA SYSTEM; LOCALIZATION; COMBINATION;
D O I
10.1007/s00261-017-1400-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aims to investigate the role of diffusion-weighted imaging (DWI) and T-2-weighted imaging (T2WI) in combination for the detection of prostate cancer, specifically assessing the role of high b-values (> 1000 s/mm(2)), with a systematic review and meta-analysis of the existing published data. The electronic databases MEDLINE, EMBASE, and OpenSIGLE were searched between inception and September 1, 2017. Eligible studies were those that reported the sensitivity and specificity of DWI and T2WI for the diagnosis of prostate cancer by visual assessment using a histopathologic reference standard. The QUADAS-2 critical appraisal tool was used to assess the quality of included studies. A meta-analysis with pooling of sensitivity, specificity, likelihood, and diagnostic odds ratios was undertaken, and a summary receiver-operating characteristics (sROC) curve was constructed. Predetermined subgroup analysis was also performed. Thirty-three studies were included in the final analysis, evaluating 2949 patients. The pooled sensitivity and specificity were 0.69 (95% CI 0.68-0.69) and 0.84 (95% CI 0.83-0.85), respectively, and the sROC AUC was 0.84 (95% CI 0.81-0.87). Subgroup analysis showed significantly better sensitivity with high b-values (> 1000 s/mm(2)). There was high statistical heterogeneity between studies. The diagnostic accuracy of combined DWI and T2WI is good with high b-values (> 1000 s/mm(2)) seeming to improve overall sensitivity while maintaining specificity. However, further large-scale studies specifically looking at b-value choice are required before a categorical recommendation can be made.
引用
收藏
页码:1787 / 1797
页数:11
相关论文
共 50 条
  • [1] The diagnostic accuracy of high b-value diffusion- and T2-weighted imaging for the detection of prostate cancer: a meta-analysis
    Tom J. Syer
    Keith C. Godley
    Donnie Cameron
    Paul N. Malcolm
    Abdominal Radiology, 2018, 43 : 1787 - 1797
  • [2] Accuracy of high b-value diffusion-weighted MRI for prostate cancer detection: a meta-analysis
    Godley, Keith Craig
    Syer, Tom Joseph
    Toms, Andoni Paul
    Smith, Toby Oliver
    Johnson, Glyn
    Cameron, Donnie
    Malcolm, Paul Napier
    ACTA RADIOLOGICA, 2018, 59 (01) : 105 - 113
  • [3] Diagnostic accuracy of high b-value diffusion weighted imaging for patients with prostate cancer: a diagnostic comprehensive analysis
    Li, Chao
    Li, Na
    Li, Zhanzhan
    Shen, Liangfang
    AGING-US, 2021, 13 (12): : 16404 - 16424
  • [4] Pancreatic neuroendocrine tumor: Added value of fusion of T2-weighted imaging and high b-value diffusion-weighted imaging for tumor detection
    Brenner, Renata
    Metens, Thierry
    Bali, Maria
    Demetter, Pieter
    Matos, Celso
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (05) : E746 - E749
  • [5] Prostate Cancer: Utility of Fusion of T2-Weighted and High b-Value Diffusion-Weighted Images for Peripheral Zone Tumor Detection and Localization
    Rosenkrantz, Andrew B.
    Mannelli, Lorenzo
    Kong, Xiangtian
    Niver, Ben E.
    Berkman, Douglas S.
    Babb, James S.
    Melamed, Jonathan
    Taneja, Samir S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (01) : 95 - 100
  • [6] The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis
    Chen Jie
    Liu Rongbo
    Tan Ping
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1929 - 1941
  • [7] The value of diffusion-weighted imaging in the detection of prostate cancer: a meta-analysis
    Chen Jie
    Liu Rongbo
    Tan Ping
    European Radiology, 2014, 24 : 1929 - 1941
  • [8] Automated prostate cancer detection using T2-weighted and high-b-value diffusion-weighted magnetic resonance imaging
    Kwak, Jin Tae
    Xu, Sheng
    Wood, Bradford J.
    Turkbey, Baris
    Choyke, Peter L.
    Pinto, Peter A.
    Wang, Shijun
    Summers, Ronald M.
    MEDICAL PHYSICS, 2015, 42 (05) : 2368 - 2378
  • [9] Evaluation of the impact of computed high b-value diffusion-weighted imaging on prostate cancer detection
    Sadhna Verma
    Saradwata Sarkar
    Jason Young
    Rajesh Venkataraman
    Xu Yang
    Anil Bhavsar
    Nilesh Patil
    James Donovan
    Krishnanath Gaitonde
    Abdominal Radiology, 2016, 41 : 934 - 945
  • [10] Evaluation of the impact of computed high b-value diffusion-weighted imaging on prostate cancer detection
    Verma, Sadhna
    Sarkar, Saradwata
    Young, Jason
    Venkataraman, Rajesh
    Yang, Xu
    Bhavsar, Anil
    Patil, Nilesh
    Donovan, James
    Gaitonde, Krishnanath
    ABDOMINAL RADIOLOGY, 2016, 41 (05) : 934 - 945