Inherent Strength of the osteo-WEDGE™ Bone Plate Locking System for Arthrodesis of the First Metatarsocuneiform Joint: A Biomechanical Study

被引:1
|
作者
Graham, Michael E. [1 ]
Chikka, Avanthi [1 ]
Goel, Vijay K. [2 ,3 ,4 ,5 ,6 ,7 ,8 ,9 ]
机构
[1] Graham Int Implant Inst, Macomb, MI USA
[2] Univ Toledo, Coll Engn, Dept Bioengn, E CORE, 2801 W Bancroft St, Toledo, OH 43606 USA
[3] Univ Toledo, Coll Engn, Dept Orthopaed Surg, E CORE, 2801 W Bancroft St, Toledo, OH 43606 USA
[4] Univ Toledo, Coll Med, Dept Bioengn, E CORE, 2801 W Bancroft St, Toledo, OH 43606 USA
[5] Univ Toledo, Coll Med, Dept Orthopaed Surg, E CORE, 2801 W Bancroft St, Toledo, OH 43606 USA
[6] Univ Toledo, Coll Engn, Dept Bioengn, E CORE,Orthopaed Bioengn, 2801 W Bancroft St, Toledo, OH 43606 USA
[7] Univ Toledo, Coll Engn, Dept Orthopaed Surg, E CORE,Orthopaed Bioengn, 2801 W Bancroft St, Toledo, OH 43606 USA
[8] Univ Toledo, Coll Med, Dept Bioengn, E CORE,Orthopaed Bioengn, 2801 W Bancroft St, Toledo, OH 43606 USA
[9] Univ Toledo, Coll Med, Dept Orthopaed Surg, E CORE,Orthopaed Bioengn, 2801 W Bancroft St, Toledo, OH 43606 USA
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2016年 / 55卷 / 03期
关键词
biomechanics; bone plate; first ray instability; metatarsocuneiform arthrodesis; metatarsus primus varus; screws; METATARSUS-PRIMUS-VARUS; HALLUX-VALGUS DEFORMITY; LAPIDUS PROCEDURE; PROSPECTIVE COHORT; OSTEOTOMIES; COMPLICATIONS; PRESSURE; FOREFOOT; FIXATION; FORCES;
D O I
10.1053/j.jfas.2015.12.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
First metatarsocuneiform joint arthrodesis with a locking bone plate and screw system has been effectively used to correct metatarsus primus varus and instability of the first ray. The goal of the present cadaveric biomechanical study was to quantify and compare the inherent strength of the first metatarsocuneiform joint and surrounding bones fixated with the osteo-WEDGE (TM) bone plate locking system (OW) with that of intact specimens. Fourteen fresh-frozen adult human cadaveric foot specimens consisting of the first metatarsal and medial cuneiform bones with intact joint capsules and ligaments were used. The OW was implanted in 7 of these specimens at the first metatarsal cuneiform joint (MCJ), and the remaining 7 specimens were left intact. Each of the specimens was then subjected to axial force to simulate dorsiflexion of the first metatarsal using a cantilever bending test setup. Load was applied on the plantar aspect of the first metatarsal head until failure of the construct. The mean load and bending moment on the first MCJ at failure for the implanted specimens were 119.98 +/- 56.76 N and 5.57 +/- 2.71 Nm, respectively. For the intact specimens, the mean load and bending moment on the first MCJ at failure were 107.93 +/- 60.90 N and 6.07 +/- 3.18 Nm, respectively. None of the specimens showed catastrophic failure within the physiologic loading limits. These results imply that the mechanical strength of the OW is comparable to that of intact specimens. Thus, the first MCJ and surrounding bones fixated with an OW should be able to effectively withstand the vertical ground reaction forces the same as intact specimens. (C) 2016 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:444 / 449
页数:6
相关论文
共 8 条
  • [1] Screw fixation compared to H-locking plate fixation for first metatarsocuneiform arthrodesis: A biomechanical study
    Cohen, DA
    Parks, BG
    Schon, LC
    FOOT & ANKLE INTERNATIONAL, 2005, 26 (11) : 984 - 989
  • [2] Crossed screws versus dorsomedial locking plate with compression screw for first metatarsocuneiform arthrodesis: A cadaver study
    Gruber, Florian
    Sinkov, Vladimir S.
    Bae, Su-Young
    Parks, Brent G.
    Schon, Lew C.
    FOOT & ANKLE INTERNATIONAL, 2008, 29 (09) : 927 - 930
  • [3] A Novel Plating System for First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Hybrid and Traditional Locking Plate Constructs
    Elattar, Osama
    Andrews, Nicholas A.
    Halstrom, Jared
    Harrelson, Whitt M.
    Nair, Pallavi
    Shah, Ashish
    FOOT & ANKLE SPECIALIST, 2023, 16 (06) : 537 - 546
  • [4] Arthrodesis of the first metatarsophalangeal joint: A biomechanical study comparing memory compression staples, cannulated screws, and a dorsal plate
    Neufeld, SK
    Parks, BG
    Naseef, GS
    Melamed, EA
    Schon, LC
    FOOT & ANKLE INTERNATIONAL, 2002, 23 (02) : 97 - 101
  • [5] Comparative analysis of mechanical conditions in bone union following first metatarsophalangeal joint arthrodesis with varied locking plate positions: A finite element analysis
    Sabik, Agnieszka
    Daszkiewicz, Karol
    Witkowski, Wojciech
    Luczkiewicz, Piotr
    PLOS ONE, 2024, 19 (05):
  • [6] Biomechanical analysis of a magnesium plantar plate prototype system for the first tarsometatarsal joint fusion: a cadaveric study
    Zhou, Peng
    Ribeiro, Marx
    Greven, Johannes
    Praster, Maximilian
    Seitz, Jan-Marten
    Habicht, Simon
    Hildebrand, Frank
    Balmayor, Elizabeth R.
    Lichte, Philipp
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [7] Radiographic and Clinical Outcomes of First Tarsometatarsal Joint Arthrodesis With a Biplanar Locking Plate System Versus the Modified Lapidus Technique With Crossed-Screw Fixation: A Retrospective Multicenter Comparison
    Fletcher, Amanda N.
    Droz, Lindsey G.
    Fuller, Robert
    Rajan, Lavan
    Zhu, Jiaqi
    Easley, Mark E.
    Nunley, James A.
    Cody, Elizabeth A.
    HSS JOURNAL, 2024,
  • [8] Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses-an Ex Vivo Biomechanical Study
    Salazar Latorre, Carlos Adolfo
    de Souza, Anderson Fernando
    Ramirez Ramos, Paula Andrea
    Nobrega, Fernanda Silveira
    Mulder van de Graaf, Guilherme Maia
    Martins Pereira, Cesar Augusto
    Auada Ferrigno, Cassio Ricardo
    Hendrickson, Dean A.
    do Valle De Zoppa, Andre Luis
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2020, 94