Ultrasound-enhanced thrombolysis

被引:0
|
作者
Motarjeme, Amir [1 ]
机构
[1] Midwest Vasc Inst Illinois, Downers Grove, IL 60515 USA
关键词
thrombosis; peripheral arterial occlusion; deep vein thrombosis; thrombolysis; ultrasound; acute occlusion; chronic occlusion;
D O I
10.1583/1545-1550(2007)14[251:UT]2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To report a single-center clinical experience with ultrasound-enhanced thrombolysis in the treatment of both arterial and venous thromboses. Methods: From January 2005 to June 2006, 33 patients (23 men; age range 39-90 years) with 36 occlusions were treated using ultrasound-enhanced thrombolytic therapy for acute and chronic arterial and venous occlusions. After diagnostic angiography, the occlusions were crossed with an appropriately sized Lysus infusion catheter for infusion of urokinase (80,000-120,000 IU/h). Results: Technical success and complete lysis was achieved in 96% of the arterial and 83% of the venous occlusions. Two patients with chronic occlusions (one superficial femoral artery and one iliac vein) were refractory to lytic therapy. Average time for complete lysis was 16.4 hours (range 3-25) for arterial occlusions and 21.2 hours (range 6-43) in patients with deep vein thrombosis. Conclusion: Successful clot lysis can be achieved with a high rate of success in a shorter time than conventional thrombolysis using ultrasound-enhanced thrombolysis in both acute and chronic arterial and venous thromboses.
引用
下载
收藏
页码:251 / 256
页数:6
相关论文
共 50 条
  • [1] Ultrasound-enhanced thrombolysis
    Francis, CW
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (03): : 239 - 246
  • [2] SHAKEN AND STIRRED: MECHANISMS OF ULTRASOUND-ENHANCED THROMBOLYSIS
    Bader, Kenneth B.
    Gruber, Matthew J.
    Holland, Christy K.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01): : 187 - 196
  • [3] Ultrasound-enhanced thrombolysis from bedside to bench
    Tsivgoulis, Georgios
    Alexandrov, Andrei
    STROKE, 2008, 39 (05) : 1404 - 1405
  • [4] Ultrasound-enhanced thrombolysis for stroke: Clinical significance
    Alexandrov, Andrei V.
    European Journal of Ultrasound, 2002, 16 (1-2) : 131 - 140
  • [5] Ultrasound-Enhanced Thrombolysis: From Bedside to Bench
    Eggers, Juergen
    STROKE, 2008, 39 (12) : E193 - E193
  • [6] In vitro models for assessing transcranial ultrasound-enhanced thrombolysis
    Meairs, S
    Dempfle, CE
    STROKE, 2005, 36 (05) : 929 - 930
  • [7] Ultrasound-Enhanced Thrombolysis: From Bedside to Bench Response
    Tsivgoulis, Georgios
    Alexandrov, Andrei V.
    STROKE, 2008, 39 (12) : E194 - E194
  • [8] Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke
    Nogueira, R. C.
    Norremose, K. A.
    Esteves, A. N.
    Oliveira, M. L.
    Almeida, K. J.
    Bor-Seng-Shu, E.
    Yamamoto, F. I.
    Evaristo, E. F.
    Teixeira, M. J.
    CEREBROVASCULAR DISEASES, 2013, 35 : 64 - 64
  • [9] Ultrasound-enhanced systemic thrombolysis for acute ischemic stroke
    Alexandrov, AV
    Molina, CA
    Grotta, JC
    Garami, Z
    Ford, SR
    Alvarez-Sabin, J
    Montaner, J
    Saqqur, M
    Demchuk, AM
    Moye, LA
    Hill, MD
    Wojner, AW
    Al-Senani, F
    Burgin, S
    Calleja, S
    Campbell, M
    Chen, CI
    Chernyshev, O
    Choi, J
    El-Mitwalli, A
    Felberg, R
    Ford, S
    Garami, Z
    Irr, W
    Grotta, J
    Hall, C
    Iguchi, Y
    Ireland, J
    Labiche, L
    Malkoff, M
    Morgenstern, L
    Noser, E
    Okon, N
    Piriyawat, P
    Robinson, D
    Shaltoni, H
    Shaw, S
    Uchino, K
    Yatsu, F
    Alvarez-Sabín, J
    Arenillas, JF
    Huertas, R
    Molina, C
    Montaner, J
    Ribó, M
    Rubiera, M
    Santamarina, E
    Saqqur, M
    Alchtar, N
    O'Rourke, F
    NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (21): : 2170 - 2178
  • [10] Ultrasound-enhanced thrombolysis with tPA-loaded echogenic liposomes
    Shaw, George J.
    Meunier, Jason M.
    Huang, Shao-Ling
    Lindsell, Christopher J.
    McPherson, David D.
    Holland, Christy K.
    THROMBOSIS RESEARCH, 2009, 124 (03) : 306 - 310