Potential Investigation of Membrane Energy Recovery Ventilators for the Management of Building Air-Conditioning Loads

被引:4
|
作者
Ashraf, Hadeed [1 ]
Sultan, Muhammad [1 ]
Sajjad, Uzair [2 ]
Shahzad, Muhammad Wakil [3 ]
Farooq, Muhammad [4 ]
Ibrahim, Sobhy M. [5 ]
Khan, Muhammad Usman [6 ]
Jamil, Muhammad Ahmad [3 ]
机构
[1] Bahauddin Zakariya Univ, Fac Agr Sci & Technol, Dept Agr Engn, Multan 60800, Pakistan
[2] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[3] Northumbria Univ, Dept Mech & Construct Engn, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[4] Univ Engn & Technol, Dept Mech Engn, Lahore 39161, Pakistan
[5] King Saud Univ, Coll Sci, Dept Biochem, POB 2455, Riyadh 11451, Saudi Arabia
[6] Univ Agr Faisalabad, Fac Agr Engn & Technol, Dept Energy Syst Engn, Faisalabad 38040, Pakistan
关键词
membrane energy recovery ventilator; energy recovery potential; Maisotsenko cycle evaporative cooling; building air-conditioning; human thermal comfort; Pakistan; EVAPORATIVE COOLING SYSTEM; PERFORMANCE; VALIDATION; EFFICIENCY; CONDENSER; HOT;
D O I
10.3390/en15062139
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present study provides insights into the energy-saving potential of a membrane energy recovery ventilator (ERV) for the management of building air-conditioning loads. This study explores direct (DEC), Maisotsenko cycle (MEC) evaporative cooling, and vapor compression (VAC) systems with ERV. Therefore, this study aims to explore possible air-conditioning options in terms of temperature, relative humidity, human thermal comfort, wet bulb effectiveness, energy saving potential, and CO2 emissions. Eight different combinations of the above-mentioned systems are proposed in this study i.e., DEC, MEC, VAC, MEC-VAC, and their possible combinations with and without ERVs. A building was modeled in DesignBuilder and simulated in EnergyPlus. The MEC-VAC system with ERV achieved the highest temperature gradient, wet bulb effectiveness, energy-saving potential, optimum relative humidity, and relatively lower CO2 emissions i.e., 19.7 degrees C, 2.2, 49%, 48%, and 499.2 kgCO(2)/kWh, respectively. Thus, this study concludes the hybrid MEC-VAC system with ERV the optimum system for the management of building air-conditioning loads.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Testing for Energy Recovery Ventilators and Energy Saving Analysis with Air-Conditioning Systems
    Yang, Peng
    Li, Li
    Wang, Jianqin
    Huang, Guilin
    Peng, Jingli
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 438 - 445
  • [2] AIR-CONDITIONING AND ENERGY MANAGEMENT
    HOUGH, B
    REFRIGERATION AND AIR CONDITIONING, 1976, 79 (937): : 46 - &
  • [3] Passive pre-cooling potential for reducing building air-conditioning loads in hot climates
    Chaudhry, Hassam Nasarullah
    Hughes, Ben Richard
    HVAC&R RESEARCH, 2014, 20 (07): : 738 - 750
  • [4] Effect of Thermal Bridges in InsulatedWalls on Air-Conditioning Loads Using Whole Building Energy Analysis
    Zedan, Mohamed F.
    Al-Sanea, Sami
    Al-Mujahid, Abdulaziz
    Al-Suhaibani, Zeyad
    SUSTAINABILITY, 2016, 8 (06):
  • [5] Sustainability of Shallow Geothermal Energy for Building Air-Conditioning
    Aquino, Andrea
    Scrucca, Flavio
    Bonamente, Emanuele
    ENERGIES, 2021, 14 (21)
  • [6] The Potential of Heat Recovery for Air-Conditioning in Sugar Industry
    Uphade D.B.
    Journal of The Institution of Engineers (India): Series C, 2021, 102 (5) : 1299 - 1309
  • [7] USE OF RADIATION CONTROL COATINGS TO REDUCE BUILDING AIR-CONDITIONING LOADS
    YARBROUGH, DW
    ANDERSON, RW
    ENERGY SOURCES, 1993, 15 (01): : 59 - 66
  • [8] Energy impact of vacuum-based membrane dehumidification in building air-conditioning applications
    Cho, Hye-Jin
    Cheon, Seong-Yong
    Jeong, Jae-Weon
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [9] An Optimization Management Strategy for Energy Efficiency of Air Conditioning Loads in Smart Building
    Fan, Rui
    Li, Yong
    Cao, Yijia
    Xie, Wei
    Tan, Yi
    Cai, Ye
    2016 IEEE 16TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2016,
  • [10] Membrane air-conditioning system driven by renewable energy
    Li, Xiu-Wei
    Zhang, Xiao-Song