Design and characteristics analysis of a new vibration reduction system for in service long span transmission tower

被引:3
|
作者
Liu, Jinghua [1 ]
Li, Ziming [2 ]
Liu, Wenwu [3 ]
Hu, Changsheng [4 ]
Zhang, Chunhua [5 ]
机构
[1] State Grid Corp China, Equipment Dept, Beijing 100031, Peoples R China
[2] State Grid Heilongjiang Elect Power Co Ltd, Harbin 150090, Heilongjiang, Peoples R China
[3] Northeast Agr Univ, Coll Engn, Harbin 150030, Heilongjiang, Peoples R China
[4] Harbin Inst Technol, Sch Mechatron Engn, Harbin 150001, Heilongjiang, Peoples R China
[5] Liaoning Elect Power Co Ltd, Dandong Power Supply Co, Dandong 11800, Peoples R China
关键词
LINE SYSTEM; DAMPER;
D O I
10.1038/s41598-022-15659-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The wind-induced fatigue is the main factor leading to reduction of the bearing capacity of long-span transmission towers. In order to reduce the harm of wind vibration, this paper takes the 500 kV Jiamusi region ISLSTT (in service long span transmission tower) as the research object, and a new kind of vibration reduction system is proposed based on a steel wire rope damping structure, with which the vibration characteristics of ISLSTT is analyzed. Firstly, the layout and components of the new vibration reduction system are described, and the damping performance of which is verified and analyzed by finite element method. Secondly, the nonlinear finite element dynamic simulation model of ISLSTT with the new vibration reduction system is established, and the multi-dimensional fluctuating wind speed time history satisfying Davenport wind speed spectrum is given by harmonic superposition method in the time domain. Based on the Bernoulli theorem, the corresponding time history of wind pressure is obtained, and the random wind load is applied to the finite element model to verify the feasibility and efficient of the new vibration reduction system. Finally, the aero-elastic wind tunnel test model of ISLSTT with the new vibration reduction system is built, and the time history curves of stress and acceleration at key points under different wind directions are obtained. By comparing with the un-damped system, it is demonstrated that the average damping efficiency of this method in the scale of stress and acceleration is 72.88% and 77.17%, respectively. The simulation and wind tunnel test results also demonstrate that the vibration reduction system based on wire rope damping structure can effectively reduce the vibration of ISLSTT caused by the non-uniformity of wind speed. The research results lay a solid foundation for the vibration reduction design of in service long span tower-line system in future.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Design and characteristics analysis of a new vibration reduction system for in service long span transmission tower
    Jinghua Liu
    Ziming Li
    Wenwu Liu
    Changsheng Hu
    Chunhua Zhang
    Scientific Reports, 12
  • [2] Numerical analysis on wind-induced vibration response of long-span transmission tower-line system
    Li, Xianxin
    Ding, Binghao
    Qi, Daokun
    Zhang, Kaixin
    Wang, Miaomiao
    GRADEVINAR, 2024, 76 (09): : 829 - 838
  • [3] Rain-wind-induced vibration Control for Long Span Transmission Tower
    Tian, Li
    Jin, Shu
    Wang, Zilong
    ADVANCES IN INTELLIGENT STRUCTURE AND VIBRATION CONTROL, 2012, 160 : 240 - +
  • [4] Design and analysis of an aeroelastic model for the 1 000 kV Sutong long span transmission tower-line system
    Zhao S.
    Yan Z.
    Li Z.
    Dong J.
    Nie X.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (12): : 1 - 8
  • [5] Comfort evaluation and vibration reduction design of long span footbridges
    Qian, Ji
    Sun, Li-Min
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2011, 45 (05): : 677 - 681
  • [6] Modeling and modal analysis of the structure of long-span transmission tower
    Li, Kai
    Zhu, Rui
    Wang, Zhenguo
    Zhou, Xiaoyu
    Wang, Mingxin
    Xu, Siyu
    Gong, Yicheng
    JOURNAL OF COMPUTATIONAL METHODS IN SCIENCES AND ENGINEERING, 2023, 23 (03) : 1491 - 1501
  • [7] Dynamic Response analysis of Long Span Transmission Tower under Tornado
    Gao Qiang
    Ren Chao
    Xu Yang
    Liu Zhen-yao
    TRENDS IN BUILDING MATERIALS RESEARCH, PTS 1 AND 2, 2012, 450-451 : 1257 - +
  • [8] Wire-breaking induced vibration and control of long-span electric transmission tower-line system
    School of Civil Engineering and Mechanics, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    Wuhan Ligong Daxue Xuebao, 2008, 9 (84-88):
  • [9] Development and application of a new type of TMD in transmission tower vibration reduction
    Lei X.
    Xie W.
    Nie M.
    Niu H.
    Chen J.
    Wang Y.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (13): : 73 - 80
  • [10] Sesismic responses of long-span transmission tower-line system
    Department of Civil Engineering, Zhejiang University, Hangzhou 310027, China
    不详
    不详
    Gongcheng Lixue, 2008, 11 (212-217):