A simple and sensitive fluorescence assay for biothiol and acetylcholinesterase activity detection based on a HSA-AuNCs@Cu2+ complex

被引:11
|
作者
Ge, Jia [1 ]
Qi, Zhangyu [2 ]
Zhang, Liangliang [2 ]
机构
[1] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450001, Henan, Peoples R China
[2] Guangxi Normal Univ, Sch Chem & Pharmaceut Sci, State Key Lab Chem & Mol Engn Med Resources, Guilin 541004, Peoples R China
基金
中国国家自然科学基金;
关键词
LABEL-FREE; SILVER NANOCLUSTERS; SELECTIVE DETECTION; COLORIMETRIC DETECTION; METAL NANOCLUSTERS; FLUOROMETRIC ASSAY; GLUTATHIONE; NANOPARTICLES; SENSOR; PHARMACOLOGY;
D O I
10.1039/c9ay01815h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human serum albumin-templated gold nanoclusters (HSA-AuNCs) were successfully synthesized using human serum albumin (HSA) as bioscaffolds. The fluorescence of the HSA-AuNCs was quenched in the presence of copper ions (Cu2+) due to the formation of the HSA-AuNC@Cu2+ complex. With the addition of biothiols, Cu2+ could be removed from the surface of the HSA-AuNCs via the coordination of the biological thiols with the Cu2+ ions. As a result, an immediate fluorescence recovery occurred when the biothiols were introduced. We developed a simple and sensitive fluorescence biosensor for the detection of biothiols and acetylcholinesterase (AChE) activity based on the HSA-AuNC@Cu2+ complex. The proposed biosensor was sensitive for the detection of cysteine and glutathione. The linear ranges for cysteine, homocysteine, and glutathione were 0-400 nM, 0-400 nM, and 0-500 nM with detection limits of 16 nM, 40 nM, and 12 nM, respectively. In addition, the proposed method could also be used for the detection of AChE activity in the range of 0-10 mU mL(-1) with a detection limit of 0.05 mU mL(-1). This rapid and simple assay was successfully used for cysteine, glutathione, and AChE activity detection in human serum with a satisfactory recovery, indicating its potential in biomedical applications.
引用
收藏
页码:5031 / 5037
页数:7
相关论文
共 50 条
  • [1] Fluorescence turn-on assay for detection of serum D-penicillamine based on papain@AuNCs-Cu2+ complex
    Chen, Yifan
    Qiao, Juan
    Liu, Qianrong
    Zhang, Mingming
    Qi, Li
    ANALYTICA CHIMICA ACTA, 2018, 1026 : 133 - 139
  • [2] Simple and sensitive fluorescence assay for acetylcholinesterase activity detection and inhibitor screening based on glutathione-capped gold nanoclusters
    Zhang, Rui-Ling
    Liang, Si-Si
    Jin, Meng
    He, Tian
    Zhang, Zhi-Qi
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 : 196 - 202
  • [3] Sensitive fluorescence assay for the detection of glyphosate with NAC\\Cu2+complex
    Liu, Qiuhuan
    Li, Shijie
    Wang, Yujiong
    Yang, Liu
    Yue, Mingli
    Liu, Yulong
    Ye, Fei
    Fu, Ying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 882
  • [4] CRISPR/Cas12a-based fluorescence assay for the detection of acetylcholinesterase activity
    Wang, Hui-Yi
    Liu, Peng-Fei
    Hang, Xiao-Min
    Zhao, Kai-Ren
    Wang, Li
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 372
  • [5] Sensitive Fluorescence Assay for the Detection of Alkaline Phosphatase Based on a Cu2+-Thiamine System
    Zhao, Han
    Liu, Xinfa
    Ma, Changbei
    SENSORS, 2021, 21 (03) : 1 - 10
  • [6] UV-light-induced synthesis of PEI-CuNCs based on Cu2+-quenched fluorescence turn-on assay for sensitive detection of biothiols, acetylcholinesterase activity and inhibitor
    Yang, Jinlan
    Song, Naizhong
    Lv, Xueju
    Jia, Qiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 259 : 226 - 232
  • [7] Selective detection of glutathione based on the recovered fluorescence of BSA-AuNCs/Cu2+ system
    Zhu, Yining
    Li, Wang
    Ju, Cheng
    Gong, Xiang
    Song, Wenhao
    Zhao, Yu
    Li, Ruijun
    MICRO & NANO LETTERS, 2019, 14 (09) : 952 - 956
  • [8] Simple and sensitive fluorescence detection of trypsin with Cu2+-Bovine serum albumin complex as a peroxidase mimic
    Zhou, Qi
    Yang, Deyuan
    Huang, Xiujuan
    Chen, Yuanyuan
    Tu, Yifeng
    Yan, Jilin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 303
  • [9] A sensitive fluorescence-based assay for the detection of ExoU-mediated PLA2 activity
    Benson, Marc A.
    Schmalzer, Katherine M.
    Frank, Dara W.
    CLINICA CHIMICA ACTA, 2010, 411 (3-4) : 190 - 197
  • [10] A sensitive fluorescence biosensor based on metal ion-mediated DNAzyme activity for amplified detection of acetylcholinesterase
    Zhao, Xu-Hua
    Dai, Xiao-Chun
    Zhou, Ya-Nan
    Zhang, Han-Xiao
    Cui, Xiao-Hua
    Zhai, Xiang
    Yu, Bao-Feng
    Song, Zhi-Ling
    ANALYST, 2022, 147 (11) : 2575 - 2581