Evaluation of Retinal Nerve Fiber Layer, Ganglion Cell-Inner Plexiform Layer, and Optic Nerve Head in Glaucoma Suspects With Varying Myopia

被引:8
|
作者
Miller, Gregg D. [1 ]
Abu-Qamar, Omar [2 ]
Salim, Sarwat [2 ]
机构
[1] Tufts Univ, Sch Med, Boston, MA 02111 USA
[2] Tufts Med Ctr, New England Eye Ctr, 800 Washington St 450, Boston, MA 02111 USA
关键词
myopia; glaucoma suspect; retinal nerve fiber layer; ganglion cell-inner plexiform layer; optic nerve head; COHERENCE TOMOGRAPHY; DIAGNOSTIC ABILITY; THICKNESS; PARAMETERS;
D O I
10.1097/IJG.0000000000001834
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: Myopic glaucoma suspects, particularly with high myopia, experience thinning of nontemporal parameters of retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL), without change in optic nerve head (ONH) parameters. Purpose: The aim was to assess the effect of myopia on RNFL, GCIPL, and ONH parameters in glaucoma suspects. Materials and Methods: Seventy-six eyes of glaucoma suspects studied with Cirrus high definition optical coherence tomography were divided into low (n=27), moderate (n=25), and high myopia (n=24) groups. Optical coherence tomography parameters were correlated with spherical equivalent (SE) and evaluated with areas under the receiver operating characteristic curve for quantifying diagnostic ability to differentiate high myopia from nonhigh myopia. Results: In high myopia, SE was positively correlated with thinning of average, minimum, and nontemporal GCIPL and thinning of average and nontemporal RNFL (P<0.05 for all), but not for inferior RNFL (P=0.28). In moderate myopia, SE was correlated with thinning of inferonasal and minimum GCIPL as well as superior and inferior RNFL (P<0.05 for all). SE was not correlated with ONH parameters in moderate or high myopia (P>0.05). The largest areas under the receiver operating characteristic curve for RNFL and GCIPL parameters were for superior (0.82) and superonasal (0.80) regions, respectively, with comparable diagnostic ability (P=0.74). Conclusion: High myopia, in particular, is associated with thinning of average RNFL, average and minimum GCIPL, and nontemporal parameters of both RNFL and GCIPL, warranting consideration of refractive status in glaucoma suspects.
引用
收藏
页码:E213 / E221
页数:9
相关论文
共 50 条
  • [1] Glaucoma Diagnostic Accuracy of Ganglion Cell-Inner Plexiform Layer Thickness: Comparison with Nerve Fiber Layer and Optic Nerve Head
    Mwanza, Jean-Claude
    Durbin, Mary K.
    Budenz, Donald L.
    Sayyad, Fouad E.
    Chang, Robert T.
    Neelakantan, Arvind
    Godfrey, David G.
    Carter, Randy
    Crandall, Alan S.
    OPHTHALMOLOGY, 2012, 119 (06) : 1151 - 1158
  • [2] Effect of myopia and optic disc area on ganglion cell-inner plexiform layer and retinal nerve fiber layer thickness
    Ganekal, Sunil
    Sadhwini, M. H.
    Kagathur, Shivanna
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (07) : 1820 - 1824
  • [3] Ganglion Cell-Inner Plexiform Layer and Retina Nerve Fiber Layer Changes in Glaucoma Suspects Enable Prediction of Glaucoma Development
    Shin, Joong Won
    Sung, Kyung Rim
    Song, Min Kyung
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 210 : 26 - 34
  • [4] Evaluation of ganglion cell-inner plexiform layer thickness in the diagnosis of preperimetric glaucoma and comparison to retinal nerve fiber layer
    Deshpande, Gunjan A.
    Gupta, Richa
    Bawankule, Prashant
    Raje, Dhananjay
    Chakraborty, Moumita
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (05) : 1113 - 1119
  • [5] Diagnostic Specificities of Retinal Nerve Fiber Layer, Optic Nerve Head, and Macular Ganglion Cell-Inner Plexiform Layer Measurements in Myopic Eyes
    Aref, Ahmad A.
    Sayyad, Fouad E.
    Mwanza, Jean-Claude
    Feuer, William J.
    Budenz, Donald L.
    JOURNAL OF GLAUCOMA, 2014, 23 (08) : 487 - 493
  • [6] The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma
    Choi, Jin A.
    Shin, Hye-Young
    Park, Hae-Young Lopilly
    Park, Chan Kee
    JOURNAL OF OPHTHALMOLOGY, 2017, 2017
  • [7] Retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in children with obesity
    Selim Demir
    Samet ?zer
    Sait Alim
    Alper Günes
    Hüseyin Ortak
    Resul Yilmaz
    International Journal of Ophthalmology, 2016, 9 (03) : 434 - 438
  • [8] Retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in children with obesity
    Demir, Selim
    Ozer, Samet
    Alim, Sait
    Gunes, Alper
    Ortak, Huseyin
    Yilmaz, Resul
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (03) : 434 - 438
  • [9] Progressive Thinning of Retinal Nerve Fiber Layer and Ganglion Cell-Inner Plexiform Layer in Glaucoma Eyes with Disc Hemorrhage
    Liu, Xiongfei
    Lau, Alicia
    Hou, Huiyuan
    Moghimi, Sasan
    Proudfoot, James A.
    Chan, Eric
    Do, Jiun
    Camp, Andrew
    Welsbie, Derek
    de Moraes, Carlos Gustavo
    Girkin, Christopher A.
    Liebmann, Jeffrey M.
    Weinreb, Robert N.
    OPHTHALMOLOGY GLAUCOMA, 2021, 4 (05): : 541 - 549
  • [10] Ganglion Cell-Inner Plexiform Layer Thickness and Retinal Nerve Fiber Layer Thickness in Patients with Autosomal Dominant Optic Atrophy
    Ronnback, Cecilia
    Larsen, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)