Sensitivity analysis of structural parameters of a low-temperature heat pump sludge drying system

被引:9
|
作者
Cai, Jingyong [1 ]
Zhou, Haihua [1 ]
Zhang, Tao [1 ]
Shi, Zhengrong [1 ]
Meng, Qingliang [2 ]
机构
[1] Shanghai Univ Elect Power, Coll Energy & Mech Engn, Shanghai 201306, Peoples R China
[2] Beijing Inst Space Mech & Elect, Beijing 100094, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat pump; Sludge drying; Steady-state models; Sensitivity analysis; AIR-SIDE PERFORMANCE; MASS-TRANSFER; SIMULATION ANALYSIS; SEWAGE-SLUDGE; TUBE ROWS; DEHUMIDIFICATION; EXCHANGERS; NUMBER; MODEL; SIZE;
D O I
10.1016/j.applthermaleng.2022.118172
中图分类号
O414.1 [热力学];
学科分类号
摘要
Optimizations of the heat exchanger of the heat pump drying system were usually carried out individually, linkage effect of the whole system in practical operating was usually not considered. In addition, for a heat pump sludge drying system, optimizations mainly concentrated on the operation parameters, few theoretical analyses focused on the effect of structural parameters to the system performance. In the present study, based on the laws of energy conservation and mass conservation, a steady-state model for the heat pump sludge drying system, which interconnects the refrigerant circulation and the moist air circulation, was established. Three variables which are coefficient of performance (COP), dehumidification rate (DR), and specific moisture extraction rate (SMER) are simultaneously introduced to evaluate the system's operating and drying performances. Effects of the number of horizontal tube rows, the number of longitudinal tube rows, and the fin spacing to the above three variables are analyzed. The results show that the COP decreases with increasing the number of horizontal tube rows while increases with increasing the number of longitudinal tube rows and fin spacing. The DR increases with increasing the number of horizontal tube rows and fin spacing and decreases with increasing the number of longitudinal tube rows. The SMER has a similar variation trend to that of the DR due to their directly proportional relationship. Finally, based on the sensitivity analysis, the heat pump sludge drying system achieves better operating and drying performances when the fin spacing is 2.85 mm, the numbers of horizontal tube rows of the evaporator and condenser are 18 and 14, and the numbers of longitudinal tube rows are respectively 12 and 9.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Theoretical analysis and experimental study on a low-temperature heat pump sludge drying system
    Zhang, T.
    Yan, Z. W.
    Wang, L. Y.
    Zheng, W. J.
    Wu, Q.
    Meng, Q. L.
    [J]. ENERGY, 2021, 214
  • [2] Study on drying characteristics of sludge under different conditions based on the low-temperature sludge heat pump drying model
    Hu, Anjie
    Ma, Lina
    Liu, Dong
    Jiang, Li
    Wang, Zhenyu
    Wang, Ling
    [J]. JOURNAL OF CLEANER PRODUCTION, 2024, 450
  • [3] HEAT-PUMP FOR LOW-TEMPERATURE GRAIN DRYING
    HOGAN, MR
    AYERS, DL
    MULLER, RE
    FOSTER, GH
    RALL, EC
    DOERING, OC
    [J]. TRANSACTIONS OF THE ASAE, 1983, 26 (04): : 1234 - 1238
  • [4] Low-temperature drying using a versatile heat pump dehumidifier
    Sosle, V
    Raghavan, GSV
    Kittler, R
    [J]. DRYING TECHNOLOGY, 2003, 21 (03) : 539 - 554
  • [5] Testing of a Condensation-type Heat Pump System for Low-temperature Drying Applications
    Aktas, Mustafa
    Ceylan, Ilhan
    Gurel, Ali Etem
    [J]. INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 2014, 10 (03) : 521 - 531
  • [6] Numerical and Experimental Analysis of a Drying Chamber of a Heat Pump Sludge Drying System
    Luo, Win-Jet
    Wu, Nai-Feng
    Lin, Cheng-Yan
    Suhaeji, Deri
    [J]. 3RD FORUM IN RESEARCH, SCIENCE, AND TECHNOLOGY (FIRST 2019) INTERNATIONAL CONFERENCE, 2020, 1500
  • [7] Numerical Simulation of Heat and Mass Transfer in Sludge Low-Temperature Drying Process
    Wang, Zhenyu
    Wang, Qiang
    Lai, Ju
    Liu, Dong
    Hu, Anjie
    Xu, Lin
    Chen, Yongcan
    [J]. ENTROPY, 2022, 24 (11)
  • [8] EXERGY ANALYSIS OF A LOW-TEMPERATURE HEAT-PUMP
    RANGREJ, HA
    NARAYANKHEDKAR, KG
    [J]. CRYOGENICS, 1983, 23 (03) : 148 - 150
  • [9] Modeling of a solar and heat pump sludge drying system
    Slim, R.
    Zoughaib, A.
    Clodic, D.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07): : 1156 - 1168
  • [10] Wastewater desalination system utilizing a low-temperature heat pump
    Yang, Junling
    Zhang, Chong
    Lin, Xuejun
    Zhang, Zhentao
    Yang, Luwei
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (03) : 1132 - 1138