Assessment of single crystal diamond detector radiation hardness to 14 MeV neutrons

被引:14
|
作者
Passeri, M. [1 ,2 ]
Pompili, F. [2 ]
Esposito, B. [2 ]
Pillon, M. [2 ]
Angelone, M. [2 ]
Marocco, D. [2 ]
Pagano, G. [2 ]
Podda, S. [2 ]
Riva, M. [2 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Ing Civile & Ing Informat, Rome, Italy
[2] ENEA, Dept Fus & Nucl Safety Technol, I-00044 Rome, Italy
关键词
Neutron; Diamond; Detector; Radiation hardness; PARTICLE; CAMERA;
D O I
10.1016/j.nima.2021.165574
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Single Crystal Diamonds (sCD) have been selected as neutron detectors for the ITER Radial Neutron Camera (RNC). This paper investigates experimentally the hardness of these detectors to 14 MeV neutrons in order to have indications of their limits of applicability in the RNC. The experiment has been performed at the Frascati Neutron Generator (FNG) facility using three sCDs of different thickness (500, 300,100 mu m). The degradation of the sCD Charge Collection Efficiency (CCE) with increasing 14 MeV neutron fluence has been found to be lower with decreasing sCD thickness. Strong polarization effects produced by the trapping of charge carriers in the defects produced by the neutron irradiation are observed already at about 4. 10(14) n/cm(2) in the 100 mu m thick sCD. A software correction of the polarization effect is proposed, which enables to extend the sCD range of operation up to higher fluences. Taking into account such correction, a 50 mu m thick sCD is expected to reach 10(15) n/cm(2) with a CCE greater than 0.7.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Radiation hardness of a single crystal CVD diamond detector for MeV energy protons
    Sato, Yuki
    Shimaoka, Takehiro
    Kaneko, Junichi H.
    Murakami, Hiroyuki
    Isobe, Mitsutaka
    Osakabe, Masaki
    Tsubota, Masakatsu
    Ochiai, Kentaro
    Chayahara, Akiyoshi
    Umezawa, Hitoshi
    Shikata, Shinichi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 147 - 150
  • [2] Radiation hardness of a polycrystalline chemical-vapor-deposited diamond detector irradiated with 14 MeV neutrons
    Angelone, M
    Pillon, M
    Balducci, A
    Marinelli, M
    Milani, E
    Morgada, ME
    Pucella, G
    Tucciarone, A
    Verona-Rinati, G
    Ochiai, K
    Nishitani, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (02):
  • [3] Radiation hardness of single crystal CVD diamond detector tested with MeV energy ions
    Zamboni, Ivana
    Pastuovic, Zeljko
    Jaksic, Milko
    DIAMOND AND RELATED MATERIALS, 2013, 31 : 65 - 71
  • [4] Radiation tolerance of type IIa synthetic diamond detector for 14 MeV neutrons
    Tanaka, T
    Kaneko, JH
    Kasugai, Y
    Katagiri, M
    Takeuchi, H
    Nishitani, T
    Iida, T
    DIAMOND AND RELATED MATERIALS, 2005, 14 (11-12) : 2031 - 2034
  • [5] Response function measurement of a synthetic diamond radiation detector for 14 MeV neutrons
    Kaneko, Junichi
    Ikeda, Yujiro
    Nishitani, Takeo
    Katagiri, Masaki
    Review of Scientific Instruments, 1999, 70 (1 II): : 1100 - 1103
  • [6] Response function measurement of a synthetic diamond radiation detector for 14 MeV neutrons
    Kaneko, J
    Ikeda, Y
    Nishitani, T
    Katagiri, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1100 - 1103
  • [7] Response to 14 MeV neutrons for single-crystal diamond detectors
    Huang Guang-Wei
    Wu Kun
    Chen Ye
    Li Lin-Xiang
    Zhang Si-Yuan
    Wang Zun-Gang
    Zhu Hong-Ying
    Zhou Chun-Zhi
    Zhang Yi-Yun
    Liu Zhi-Qiang
    Yi Xiao-Yan
    Li Jin-Min
    ACTA PHYSICA SINICA, 2021, 70 (20)
  • [8] Response of a diamond detector sandwich to 14 MeV neutrons
    Osipenko, M.
    Ripani, M.
    Ricco, G.
    Caiffi, B.
    Pompili, F.
    Pillon, M.
    Verona-Rinati, G.
    Cardarelli, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 817 : 19 - 25
  • [9] Response function stability of single crystal diamond detectors to 14 MeV neutrons
    Zboril, Miroslav
    Zimbal, Andreas
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [10] Response function measurement of layered type CVD single crystal diamond radiation detectors for 14 MeV neutrons
    Kaneko, JH
    Teraji, T
    Hirai, Y
    Shiraishi, M
    Kawamura, S
    Yoshizaki, S
    Ito, T
    Ochiai, K
    Nishitani, T
    Sawamura, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3581 - 3584