Experimental Investigation on the Axially Loaded Performance of Notched Hexagonal Concrete-Filled Steel Tube (CFST) Column

被引:6
|
作者
Liu, Jing [1 ,2 ]
Li, Zhe [3 ]
Ding, Fa-Xing [2 ]
机构
[1] Hunan City Univ, Sch Civil Engn, Yiyang 413000, Hunan, Peoples R China
[2] Cent S Univ, Sch Civil Engn, Changsha 410075, Hunan, Peoples R China
[3] Cent S Univ, Sch Architecture & Art, Changsha 410075, Hunan, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
TUBULAR STUB COLUMNS; MECHANICAL-BEHAVIOR; ENERGY-ABSORPTION; COMPOSITE ACTION; MEMBERS;
D O I
10.1155/2019/2612536
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study aimed to investigate the static performance of notched hexagonal concrete-filled steel tube (CFST) stub columns through axial loading. Notch length, notch location, and notch direction in 14 CFST stub columns were experimentally studied. Stress process, failure mechanism, and ultimate strength in the notched CFST columns were analyzed. Results show that notches in steel tubes can weaken the restraining effect of steel pipes on core concrete and induce a decrease in the ultimate strength of specimens. The failure mode of components is greatly affected by notch orientation. The notch is closed under axial compression in the horizontally notched specimen, and the slotting indicates outward buckling in the vertically notched specimen. Based on the test results, a method for calculating the ultimate strength of notched hexagonal CFST columns was established. This research encourages the extensive application of these structures in civil engineering.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Behaviors of axially loaded square concrete-filled steel tube (CFST) Stub columns with notch in steel tube
    Ding, Fa-xing
    Fu, Lei
    Yu, Zhi-wu
    THIN-WALLED STRUCTURES, 2017, 115 : 196 - 204
  • [2] Mechanical behaviors of axially loaded square concrete-filled steel tube (CFST) stub columns with notch in steel tube
    Li, Biao
    Zhang, Jingke
    Ding, Faxing
    Journal of Railway Science and Engineering, 2022, 19 (04) : 1041 - 1051
  • [3] Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns
    卢亦焱
    李娜
    李杉
    梁鸿骏
    JournalofCentralSouthUniversity, 2015, 22 (06) : 2287 - 2296
  • [4] Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns
    Yi-yan Lu
    Na Li
    Shan Li
    Hong-jun Liang
    Journal of Central South University, 2015, 22 : 2287 - 2296
  • [5] Experimental investigation of axially loaded steel fiber reinforced high strength concrete-filled steel tube columns
    Lu Yi-yan
    Li Na
    Li Shan
    Liang Hong-jun
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (06) : 2287 - 2296
  • [6] Seismic performance of concrete-encased column base for hexagonal concrete-filled steel tube: experimental study
    Xu, Wu
    Han, Lin-Hai
    Li, Wei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 121 : 352 - 369
  • [7] Optimum reinforcement ratio of axially loaded reinforced concrete-filled square steel tube column
    Xiamuxi, Alifujiang
    Wang, Zongbao
    Yang, Bin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 203
  • [8] Axially loaded concrete-filled steel tubes
    Srinivasan, CN
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (10): : 1202 - 1206
  • [9] Axially loaded concrete-filled steel tubes
    Schneider, SP
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (10): : 1125 - 1138
  • [10] EXPERIMENTAL STUDY ON BEHAVIOR OF AXIALLY LOADED CONCRETE-FILLED STEEL TUBE STUB COLUMNS WITH LOCAL CORROSION
    Li Z.-L.
    Lin S.-Q.
    Zhao Y.-G.
    Wang W.-D.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (08): : 170 - 180