Analysis of Dielectric Breakdown of Hot SF6 Gas in a Gas Circuit Breaker

被引:13
|
作者
Kim, Hong-Kyu
Chong, Jin-Kyo
Song, Ki-Dong
机构
关键词
Gas circuit breaker; Hot SF6 gas; Dielectric breakdown; Critical electric field; Arc plasma; ARC; NOZZLE;
D O I
10.5370/JEET.2010.5.2.264
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the analysis of the dielectric characteristics of a hot SF6 gas in a gas circuit breaker. Hot gas flow is analyzed using the FVFLIC method considering the moving boundary, material properties of real SF6 gas, and arc plasma. In the arc model, the re-absorption of the emitted radiation is approximated with the boundary source layer where the re-absorbed radiation energy is input as an energy source term in the energy conservation equation. The breakdown criterion of a hot gas is predicted using the critical electric field as a function of temperature and pressure. To validate the simulation method, breakdown voltage for a 145kV 40kA circuit breaker was measured for various conditions. Consistent results between the simulation and experiment were confirmed.
引用
下载
收藏
页码:264 / 269
页数:6
相关论文
共 50 条
  • [1] HOT GAS-FLOW ANALYSIS IN SF6 GAS CIRCUIT-BREAKER DURING THE SHORT-CIRCUIT INTERRUPTION
    YOSHIZUMI, T
    IBUKI, K
    HOSOMI, M
    YONEZAWA, T
    KAWASAKI, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (03) : 1757 - 1764
  • [2] Electrical Strength Analysis of SF6 Gas Circuit Breaker Element
    Glushkov, Daniil A.
    Khalyasmaa, Alexandra I.
    Dmitriev, Stepan A.
    Kokin, Sergey E.
    2ND AASRI CONFERENCE ON POWER AND ENERGY SYSTEMS (PES2013), 2014, 7 : 57 - 61
  • [3] Influence of PTFE Vapor on Dielectric Breakdown Property of Hot SF6 Gas
    Wang L.
    Zhao H.
    Zhang H.
    Wang Z.
    Li X.
    Gaodianya Jishu/High Voltage Engineering, 2017, 43 (03): : 801 - 807
  • [4] RECENT SF6 GAS CIRCUIT BREAKER DEVELOPMENTS.
    SAITO, KAZUHIRO
    HONDA, HARUO
    1982, V 31 (N 3): : 151 - 156
  • [5] Hot SF6 breakdown calculations applied to high voltage circuit breaker
    Yousfi, M
    Robin-Jouan, P
    Kanzari, Z
    HIGH TEMPERATURE MATERIAL PROCESSES, 2005, 9 (04): : 573 - 582
  • [6] ANALYSIS OF THE DIELECTRIC STRENGTH OF AN SF6 CIRCUIT-BREAKER
    TREPANIER, JY
    REGGIO, M
    LAUZE, Y
    JEANJEAN, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (02) : 809 - 815
  • [7] Measurement of Hot Gas Exhaust Characteristics in SF6 Circuit Breaker with Small Model Interrupter
    Urai, Hajime
    Koizumi, Makoto
    Ooshita, Yoichi
    Yaginuma, Noriyuki
    Tsukushi, Masanori
    2013 2ND INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2013,
  • [8] Behavior of inhomogeneous high-temperature SF6 gas in a gas circuit breaker
    Uchii, T
    Iwata, K
    Kawano, H
    Nakamoto, T
    Suzuki, K
    2001 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-3, 2001, : 289 - 294
  • [9] A 500-KV CIRCUIT BREAKER USING SF6 GAS
    VANSICKLE, RC
    YECKLEY, RN
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (10): : 892 - +
  • [10] Gas flow characteristics analysis of SF6 circuit breaker using similarity theory
    Li, Liying
    Chen, Hai
    Zhang, Yaqian
    Liu, Wei
    Liu, Xiaoming
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2420 - 2425