Total hip replacements with ceramic-on-ceramic bearings

被引:0
|
作者
Milosev, Ingrid [1 ,2 ]
Trebse, Rihard [1 ]
Marjanovic, Benjamin [1 ]
Kovac, Simon [1 ]
机构
[1] Ortopedska Bolnisnica Valdoltra, Ankaran 6280, Slovenia
[2] Jozef Stefan Inst, Ljubljana 1000, Slovenia
关键词
total hip replacement; orthopaedics; ceramic; wear; fracture; WEAR PARTICLES; SIMULATOR WEAR; FEMORAL-HEAD; ALUMINA; ARTHROPLASTY; FRACTURE; THR; CYTOTOXICITY; COMPONENT; REVISION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The first generation of ceramic-on-ceramic bearings was introduced in France in 1970s. The quality of material as well as the design of ceramic components were improved in the second generation developed in 1980s. The contemporary, third generation of ceramic-on-ceramic bearings has been in use since mid 1990s. Characteristics: In vivo wear of ceramic-on-ceramic bearings is very low, <1 mm(3)/year. Ceramic wear particles formed under conditions of normal wear are nanometer-sized. Despit a common belief, these particles are not completely biologically inert. The incidence of ceramic component fracture is low. Clinical results: Long-term data for the first generation of ceramic-on-ceramic bearings show more than 60% survival at 20 years. Currently, mid-term results of the third generation are available. Although the incidence of osteolysis is significantly lower than for metal-on-polyethylene bearings, it is not possible to avoid it completely. Conclusions: Total hip replacements with ceramic-on-ceramic bearings show very low wear, the incidence of osteolysis is low and there are no biocompatibility issues, as is the case with metal-on-metal bearings. The possibility of ceramic component fracture is small, however, when it happens it is always a serious complication.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 50 条
  • [1] Ceramic-on-ceramic bearings in total hip arthroplasty
    Bierbaum, BE
    Nairus, J
    Kuesis, D
    Morrison, JC
    Ward, D
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) : 158 - 163
  • [2] Modern ceramic-on-ceramic bearings in total hip arthroplasty
    Nau, Thomas
    Raschid, Josef
    Kirnbauer, Werner
    Schwischei, Harald
    Ehall, Reinhard
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 2005, 155 (3-4) : 70 - 74
  • [3] Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty (THA)
    Sentuerk, U.
    Perka, C.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2015, 153 (02): : 198 - 202
  • [4] Direct evidence of lubrication in ceramic-on-ceramic total hip replacements
    Smith, SL
    Dowson, D
    Goldsmith, AAJ
    Valizadeh, R
    Colligon, JS
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2001, 215 (03) : 265 - 268
  • [5] A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty
    Rosneck, James
    Klika, Alison
    Barsoum, Wael
    JOURNAL OF ARTHROPLASTY, 2008, 23 (02): : 311 - 313
  • [6] Clinical failure analysis of contemporary ceramic-on-ceramic total hip replacements
    Brandt, Jan-M
    Gascoyne, Trevor C.
    Guenther, Leah E.
    Allen, Andrew
    Hedden, David R.
    Turgeon, Thomas R.
    Bohm, Eric R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (08) : 833 - 846
  • [7] Optimal wear performance of ceramic-on-ceramic bearings for total hip replacement
    Clarke, IC
    Oonishi, H
    JOINT ARTHROPLASTY, 1999, : 140 - 151
  • [8] Squeaking in Large Diameter Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty
    Tai, Stephen M.
    Munir, Selin
    Walter, William L.
    Pearce, Simon J.
    Walter, William K.
    Zicat, Bernard A.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (02): : 282 - 285
  • [9] Ceramic-on-Ceramic Total Hip Arthroplasty
    Greene, Joseph W.
    Malkani, Arthur L.
    Kolisek, Frank R.
    Jessup, Nenette M.
    Baker, Dale L.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (06): : 15 - 18
  • [10] Ceramic-on-ceramic total hip replacement
    Riska, EB
    CURRENT ORTHOPAEDICS, 1999, 13 (04): : 320 - 324