Evaluation of droplet velocity and size from nasal spray devices using phase Doppler anemometry (PDA)

被引:37
|
作者
Liu, Xiaofei [1 ]
Doub, William H. [1 ]
Guo, Changning [1 ]
机构
[1] US FDA, Div Pharmaceut Anal, St Louis, MO 63101 USA
关键词
Nasal spray; In vitro test; Aerosol; Velocity; Size; Phase Doppler anemometry; IMPACTION;
D O I
10.1016/j.ijpharm.2009.12.041
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
To determine aerosol deposition during the inhalation drug delivery, it is important to understand the combination of velocity and droplet size together. In this study, phase Doppler anemometry (PDA) was used to simultaneously characterize the aerosol velocity and droplet size distribution (DSD) of three nasal spray pumps filled with water. Thirteen sampling positions were located in the horizontal cross-sectional area of the nasal spray plumes at a distance of 3 cm from the pump orifice. The results showed droplet velocities near the center of the spray plume were higher and more consistent than those near the edge. The pumps examined showed significant differences in their aerosol velocity at the center of the spray plume, which suggest that this metric might be used as a discriminating parameter for in vitro testing of nasal sprays. Droplet size measurements performed using PDA were compared with results from laser light scattering measurements. The ability of PDA to provide simultaneous measurements of aerosol velocity and size makes it a powerful tool for the detailed investigation of nasal spray plume characteristics. Published by Elsevier B.V.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 50 条
  • [1] Assessment of the Influence Factors on Nasal Spray Droplet Velocity Using Phase-Doppler Anemometry (PDA)
    Liu, Xiaofei
    Doub, William H.
    Guo, Changning
    AAPS PHARMSCITECH, 2011, 12 (01): : 337 - 343
  • [2] Assessment of the Influence Factors on Nasal Spray Droplet Velocity Using Phase-Doppler Anemometry (PDA)
    Xiaofei Liu
    William H. Doub
    Changning Guo
    AAPS PharmSciTech, 2011, 12 : 337 - 343
  • [3] Evaluation of metered dose inhaler spray velocities using Phase Doppler Anemometry (PDA)
    Liu, Xiaofei
    Doub, William H.
    Guo, Changning
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2012, 423 (02) : 235 - 239
  • [4] Some Observations on Particle Size and Velocity Measurements Using Phase Doppler Anemometry in Plasma Spray
    J. Ma
    S.C.M. Yu
    H.W. Ng
    Y.C. Lam
    Plasma Chemistry and Plasma Processing, 2004, 24 : 85 - 115
  • [5] Some observations on particle size and velocity measurements using phase Doppler anemometry in plasma spray
    Ma, J
    Yu, SCM
    Ng, HW
    Lam, YC
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2004, 24 (01) : 85 - 115
  • [6] SIMULTANEOUS MEASUREMENT OF DROPLET VELOCITY AND SIZE AND FLAME MANTLE TEMPERATURE BY PHASE DOPPLER ANEMOMETRY AND 2-COLOR PYROMETRY
    ISRAEL, F
    TAYLOR, AMKP
    WHITELAW, JH
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (06) : 727 - 741
  • [7] PREDICTION OF DROPLET VELOCITY FROM DROPLET SIZE IN WATER SPRAY
    ARAKI, K
    MORIYAMA, A
    TERADA, K
    MORI, S
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1980, 20 (07) : 462 - 465
  • [8] Effect of aviation fuel temperature on refractive index in droplet size measurement using phase Doppler anemometry
    Dafsari, Reza Alidoost
    Vashahi, Foad
    Chandrahasan, Rakhul
    Lee, Jeekeun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (07)
  • [9] Study of droplet size and velocity of fuel containing CO2 spray by means of PDA
    Xiao, J
    Qiao, XQ
    Huang, Z
    Fang, JH
    CHINESE SCIENCE BULLETIN, 2004, 49 (11): : 1195 - 1199