In vivo alanine/EPR dosimetry in daily clinical practice:: A feasibility study

被引:41
|
作者
Ciesielski, B
Schultka, K
Kobierska, A
Nowak, R
Peimel-Stuglik, Z
机构
[1] Med Univ Gdansk, Dept Phys & Biophys, PL-80211 Gdansk, Poland
[2] Med Univ Gdansk, Dept Radiotherapy & Oncol, PL-80211 Gdansk, Poland
[3] Inst Nucl Chem & Technol, Lab Measurments Technol Doses, PL-03195 Warsaw, Poland
关键词
alanine; EPR; dosimetry; radiotherapy;
D O I
10.1016/S0360-3016(03)00196-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The objective of this study was evaluation of accuracy of in vivo dosimetry using electron paramagnetic resonance (EPR) in alanine. Additionally, we aimed to identify sources of uncertainty in dose determination and quantitative assessment of physical factors that may result in discrepancies between the measured and planned single-fraction doses. Methods and Materials: The measurements were performed using detectors in a form of 1.6 cm X 1.6 cm polyethylene sachets filled with powdered L-alanine. The detectors were taped to the patient's skin and measured the entrance doses for Co-60 and electron beams. Some detectors were covered with buildup material, and some measured the "skin dose." The EPR measurements were performed with a Varian E-4 spectrometer. Results: The calculated uncertainty of EPR measured doses was dependent on measured doses and varied from 6.6% for 0.5 Gy to 3.2% for 2 Gy. The calculated uncertainty was in concordance with experimentally determined reproducibility of EPR signals. However, the deviations between measured and planned doses exceeded the uncertainty range of EPR measurements, which can be attributed to uncertainty in determination of actually delivered doses to the detectors, on the basis of treatment planning data. Conclusion: The accuracy of dose determination by EPR measurements was shown to be achievable within the 5% limit recommended by the ICRU for doses above 0.7 Gy. The accuracy of in vivo verification of radiotherapy doses by in vivo EPR dosimetry can be improved by meticulous selection of measurement conditions, i.e., radiation fields and detector positions, ensuring accurate calculation of doses delivered to the dosimeters. (C) 2003 Elsevier Inc.
引用
收藏
页码:899 / 905
页数:7
相关论文
共 50 条
  • [1] EPR/alanine dosimetry in LDR brachytherapy - A feasibility study
    Schultka, Katarzyna
    Ciesielski, Bartlomiej
    Serkies, Krystyna
    Sawicki, Tomasz
    Tarnawska, Zofia
    Jassem, Jacek
    RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) : 171 - 175
  • [2] A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice
    Falco, Maria D.
    Giancaterino, Stefano
    De Nicola, Andrea
    Adorante, Nico
    De Lorenzo, Ramon Gimenez
    Di Tommaso, Monica
    Vinciguerra, Annamaria
    Trignani, Marianna
    Perrotti, Francesca
    Allajbej, Albina
    Fidanzio, Andrea
    Greco, Francesca
    Grusio, Mattia
    Genovesi, Domenico
    Piermattei, Angelo
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17
  • [3] In-Vivo Dosimetry: A Feasibility Study in Routine Clinical Practice
    Falco, M. D.
    Giancaterino, S.
    De Nicola, A.
    Adorante, N.
    De Lorenzo, R. Gimenez
    Di Tommaso, M.
    Vinciguerra, A.
    Trignani, M.
    Allajbej, A.
    Greco, F.
    Grusio, M.
    Piermattei, A.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S941 - S941
  • [4] Alanine-ESR in vivo dosimetry: A feasibility study and possible applications
    Kuntz, F
    Pabst, JY
    Delpech, JP
    Wagner, JP
    Marchioni, E
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1183 - 1188
  • [5] Alanine EPR dosimetry in brachytherapy
    De Angelis, C
    Onori, S
    Petetti, E
    Piermattei, A
    Azario, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (05): : 1181 - 1191
  • [6] Characteristics of a Compact Tabletop Alanine EPR System for Clinical Dosimetry
    Smith, B.
    Culberson, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E452 - E452
  • [7] RESULTS AFTER YEARS OF DAILY CLINICAL PRACTICE WITH IN VIVO IMRT EPID DOSIMETRY
    Olaciregui, I.
    Szeto, Y.
    Mans, A.
    Tielenburg, R.
    Vijlbrief, R.
    Van der Sluis, R.
    Rozendaal, R.
    Mijnheer, B.
    Sonke, J. J.
    van Herk, M.
    Stroom, J.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S512 - S513
  • [8] In vivo EPR for dosimetry
    Swartz, Harold M.
    Burke, Greg
    Coey, M.
    Demidenko, Eugene
    Dong, Ruhong
    Grinberg, Oleg
    Hilton, James
    Iwasaki, Akinori
    Lesniewski, Piotr
    Kmiec, Maciej
    Lo, Kai-Ming
    Nicolalde, R. Javier
    Ruuge, Andres
    Sakata, Yasuko
    Sucheta, Artur
    Walczak, Tadeusz
    Williams, Benjamin B.
    Mitchell, Chad A.
    Romanyukha, Alex
    Schauer, David A.
    RADIATION MEASUREMENTS, 2007, 42 (6-7) : 1075 - 1084
  • [9] In vivo alanine/electron spin resonance (ESR) dosimetry in radiotherapy of prostate cancer:: A feasibility study
    Wagner, Daniela
    Anton, Mathias
    Vorwerk, Hilke
    Gsaenger, Tammo
    Christiansen, Hans
    Poppe, Bjoern
    Hess, Clemens Friedrich
    Hermann, Robert Michael
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 (01) : 140 - 147
  • [10] A high sensitivity EPR technique for alanine dosimetry
    Haskell, EH
    Hayes, RB
    Kenner, GH
    RADIATION PROTECTION DOSIMETRY, 1998, 77 (1-2) : 43 - 49