Application of ECT to solid concentration measurements during granular flow in a rectangular model silo

被引:15
|
作者
Niedostatkiewicz, M. [1 ]
Tejchman, J. [1 ]
Grudzien, K. [2 ]
Chaniecki, Z. [2 ]
机构
[1] Gdansk Univ Technol, Fac Civil & Environm Engn, Gdansk, Poland
[2] Tech Univ Lodz, Dept Comp Engn, PL-90924 Lodz, Poland
来源
关键词
Density; Granular material; Electrical capacitance tomography; Particle Image Velocimetry; Rectangular silo; Silo flow; Solid concentration; Wall roughness; IMAGE VELOCIMETRY PIV; DEFORMATION MEASUREMENT; CAPACITANCE TOMOGRAPHY;
D O I
10.1016/j.cherd.2010.01.034
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The paper presents results of concentration changes in cohesionless sand during dynamic mass flow in a rectangular model silo composed of a bin and hopper. Electrical capacitance tomography (ECT) was used. Sensors were located outside the silo along both the periphery and height. Local horizontal one-dimensional and cross-sectional two-dimensional evolutions of solid concentrations in dry sand during silo discharge were determined. The first ones were estimated from the raw data and the latter were obtained with the aid of the reconstructed data using a Linear Back Projection algorithm (LBP) to solve an inverse problem. Experiments in a model silo were carried out with two different initial sand densities and wall roughness grades. The measured results with ECT were compared with corresponding ones obtained with a Particle Image Velocimetry (PIV) method. (C) 2010 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1037 / 1048
页数:12
相关论文
共 50 条
  • [1] Determination of bulk solid concentration changes during granular flow in a model silo with ECT sensors
    Niedostatkiewicz, M.
    Tejchman, J.
    Chaniecki, Z.
    Grudzien, K.
    CHEMICAL ENGINEERING SCIENCE, 2009, 64 (01) : 20 - 30
  • [2] Description of the silo flow and bulk solid pulsation detection using ECT
    Grudzien, Krzysztof
    Romanowski, Andrzej
    Chaniecki, Zbigniew
    Niedostatkiewicz, Maciej
    Sankowski, Dominik
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (03) : 198 - 206
  • [3] Application of particle image velocimetry (PIV) for deformation measurement during granular silo flow
    Slominski, Cezary
    Niedostatkiewicz, Maciej
    Tejchman, Jacek
    POWDER TECHNOLOGY, 2007, 173 (01) : 1 - 18
  • [4] Analysis of the bulk solid flow during gravitational silo emptying using X-ray and ECT tomography
    Grudzien, Krzysztof
    Niedostatkiewicz, Maciej
    Adrien, Jerome
    Maire, Eric
    Babout, Laurent
    POWDER TECHNOLOGY, 2012, 224 : 196 - 208
  • [5] Investigations of porosity changes during granular silo flow using electrical capacitance tomography (ECT) and particle image velocimetry (PIV)
    Niedostatkiewicz, Maciej
    Tejchman, Jacek
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2007, 24 (4-5) : 304 - 312
  • [6] ECT Image Analysis Methods for Shear Zone Measurements during Silo Discharging Process
    Grudzien, Krzysztof
    Chaniecki, Zbigniew
    Romanowski, Andrzej
    Niedostatkiewicz, Maciej
    Sankowski, Dominik
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2012, 20 (02) : 337 - 345
  • [7] PLUGGING OF THE FLOW OF GRANULAR-MATERIALS DURING THE DISCHARGE FROM A SILO
    SAKAGUCHI, H
    OZAKI, E
    IGARASHI, T
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 1993, 7 (9-10): : 1949 - 1963
  • [8] Measurement of granular temperature during silo flow by speckle visibility spectroscopy
    Chen Q.
    Zheng Z.
    Li R.
    Sun Q.
    Yang H.
    Huagong Xuebao/CIESC Journal, 2022, 73 (06): : 2603 - 2611
  • [9] Investigations of Shear Localization during Granular Silo Flow with Non-Local Hypoplastic Constitutive Model
    Wojcik, Michal
    Tejchman, Jacek
    POWDERS AND GRAINS 2009, 2009, 1145 : 641 - 644
  • [10] Empirical description of granular flow inside a model silo with vertical walls
    Sielamowicz, Irena
    Czech, Michal
    Kowalewski, Tomasz A.
    BIOSYSTEMS ENGINEERING, 2011, 108 (04) : 334 - 344