The Use of Intraoperative Three-Dimensional Echocardiography to Evaluate Origin of Bioprosthetic Aortic Valve Regurgitant Jets

被引:2
|
作者
Holmes, Michael [1 ]
Sheu, Richard [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Anesthesiol & Pain Med, 1959 NE Pacific St
关键词
aortic regurgitation; paravalvular leak; valve-in-valve; transcatheter aortic valve replacement; TAVR; transesophageal echocardiography; 3D TEE;
D O I
10.1053/j.jvca.2019.05.044
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Degradation of bioprosthetic aortic valves can eventually lead to both paravalvular and intravalvular regurgitation. However, differentiating between the two may be difficult in the case of multiple lesions in close proximity or highly eccentric jets. Whereas such exact distinction may be of little procedural significance in open cardiac surgery, it is of crucial importance when approaching such lesions in the catheterization laboratory or hybrid operating room. Interventions on one lesion often have a significant effect on the other. For example, guidewires may damage new bioprosthetic valve leaflets and dislodge vascular plugs. Even more concerning is the possibility of undergoing a lengthy and risky procedure on a lesion that does not truly exist. Fortunately, the use of three-dimensional Doppler echocardiography can expand our vision beyond the single imaging plane of a standard two-dimensional examination, allowing extensive manipulation of cutting planes and a wider field of view. Regurgitant jets can thus be tracked in a way that may be otherwise impossible, better quantifying their true origins. Here the authors present a unique case of misdiagnosis after surgical aortic valve degradation, where the use of intraoperative three-dimensional echocardiography significantly altered the preoperative plan and reduced operative time. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:3504 / 3508
页数:5
相关论文
共 50 条
  • [1] Morphology of the rheumatic mitral regurgitant valve by three-dimensional echocardiography
    Wong, SP
    French, RA
    Bolson, EL
    Legget, ME
    Sheehan, FH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 480A - 480A
  • [2] Three-dimensional visualization and volumetric assessment of valvular regurgitant jets in echocardiography
    Glombitza, G
    De Simone, R
    Merdes, M
    Mayer, A
    Vahl, CF
    Hagl, S
    Meinzer, HP
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 170 - 175
  • [3] Morphologic features of the rheumatic mitral regurgitant valve by three-dimensional echocardiography
    Wong, S
    French, R
    Bolson, E
    McDonald, J
    Leggert, M
    Sheehan, F
    AMERICAN HEART JOURNAL, 2001, 142 (05) : 897 - 907
  • [4] Three-dimensional geometry of regurgitant jets in mitral insufficiency
    Hofmann, T
    Franzen, O
    Dehn, C
    Knap, M
    CIRCULATION, 2002, 106 (19) : 505 - 505
  • [5] Three-dimensional echocardiography in the assessment of mitral and aortic valve regurgitation
    Lange, A
    Palka, P
    Donnelly, E
    Scalia, G
    Rahman, S
    Burstow, D
    EUROPEAN HEART JOURNAL, 2000, 21 : 4 - 4
  • [6] Quantification of aortic valve area using three-dimensional echocardiography
    de Isla, Leopoldo Perez
    Zamorano, Jose
    de la Yglesia, Rocio Perez
    Cioccarelli, Sara
    Almeria, Carlos
    Rodrigo, Jose L.
    Aubele, Ada L.
    Herrera, Dionisio
    Mataix, Luis
    Serra, Viviana
    Macaya, Carlos
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (05): : 494 - 500
  • [7] Quadricuspid Aortic Valve Visualized by Three-Dimensional Transthoracic Echocardiography
    Acar, Eser
    Sahin, Tayfun
    Yilmaz, Irem
    Celikyurt, Umut
    CASE REPORTS IN CARDIOLOGY, 2011, 2011
  • [8] A feasibility trial of intraoperative three-dimensional transesophageal echocardiography in valve surgery
    Abraham, TP
    Warner, JG
    Kon, ND
    Fowle, K
    Kitzman, DW
    CIRCULATION, 1996, 94 (08) : 1226 - 1226
  • [9] Intraoperative Three-Dimensional Transesophageal Echocardiography Facilitates Aortic Plaque Evaluation
    Kwon, Won-Kyoung
    Mohamed, Nazri
    Yu, Ga-Yon
    Kim, Rina
    Kim, Tae-Yop
    ANESTHESIA AND ANALGESIA, 2016, 122 (02): : 354 - 357
  • [10] Intraoperative three-dimensional aortic valve estimation is clinically feasible in patients with aortic valve stenosis
    Mukai, S
    Nomura, M
    Hashimoto, T
    Sugino, Y
    Yasunaka, H
    Zaitsu, A
    Mitsunari, H
    Kurokawa, S
    Seino, Y
    Nagasawa, C
    Morino, R
    Kawai, A
    Nomura, Y
    ANESTHESIA AND ANALGESIA, 2004, 98 (04): : 28 - 28