Technical Note: Homogeneity of Gafchromic® EBT2 film

被引:105
|
作者
Hartmann, Bernadette [1 ,2 ]
Martisikova, Maria [1 ]
Jaekel, Oliver [1 ,3 ]
机构
[1] German Canc Res Ctr, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Univ Halle Wittenberg, Inst Phys, D-06120 Halle, Germany
[3] Univ Klinikum Heidelberg, Heidelberger Lonenstrahl Therapiezentrum HIT, D-69120 Heidelberg, Germany
关键词
dosimeters; dosimetry; radiation therapy; FLAT-BED SCANNER; RADIOCHROMIC FILM; DOSIMETRY;
D O I
10.1118/1.3368601
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Methods: A scan protocol established for EBT film and published previously was used. The uniformity of the film coloration was investigated for unirradiated and irradiated EBT2 film sheets. The dose response of EBT2 film was measured and the influence of film inhomogeneities on dose determination was evaluated. Results: Inhomogeneities in pixel values of up to +/- 3.7% within one film were detected. The relative inhomogeneities were found to be approximately independent of the dose. Nonuniformities of the film response lead to uncertainties in dose determination of +/- 8.7% at 1 Gy. When using net optical densities for dose calibration, uncertainties in dose determination amount to more than +/- 6%. Conclusions: EBT2 films from the lot investigated in this study show response inhomogeneities, which lead to uncertainties in dose determination exceeding the commonly accepted tolerance levels. It is important to test further EBT2 lots regarding homogeneity before using the film in clinical routine.
引用
收藏
页码:1753 / 1756
页数:4
相关论文
共 50 条
  • [41] An Assessment of EBT2 Gafchromic Film as a Potential Means for Depth Dose Measurement of Radiotherapy Beams
    Arjomandy, B.
    Tailor, R.
    Zhao, L.
    Devic, S.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [42] Quality Assurance of Complex Rotational and Stereotactic IMRT Treatments Using Gafchromic EBT2 Film
    Kairn, T.
    Aland, T.
    Hardcastle, N.
    Hill, B.
    Kenny, J.
    Knight, R.
    Meldrum, R.
    Middlebrook, N.
    Tome, W.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [43] A study on comparison of Gafchromic EBT2 film response under single and cumulative exposure conditions
    Ganapathy, K.
    Kurup, P. G. G.
    Murali, V.
    Muthukumaran, M.
    Velmurugan, J.
    JOURNAL OF MEDICAL PHYSICS, 2013, 38 (04) : 173 - 177
  • [44] Comparison of Gafchromic EBT2 and EBT3 films for clinical photon and proton beams
    Reinhardt, S.
    Hillbrand, M.
    Wilkens, J. J.
    Assmann, W.
    MEDICAL PHYSICS, 2012, 39 (08) : 5257 - 5262
  • [45] Characterizing the marker-dye correction for Gafchromic® EBT2 film: A comparison of three analysis methods
    McCaw, Travis J.
    Micka, John A.
    DeWerd, Larry A.
    MEDICAL PHYSICS, 2011, 38 (10) : 5771 - 5777
  • [46] The measurement of backscatter factors of kilovoltage X-ray beams using Gafchromic™ EBT2 film
    L. Smith
    R. Hill
    M. Nakano
    J. Kim
    Z. Kuncic
    Australasian Physical & Engineering Sciences in Medicine, 2011, 34 : 261 - 266
  • [47] Feasibility Study On Use of Gafchromic EBT2 Film as An Absolute Dosimetry QA System for SBRT Treatment
    Duggar, W.
    Yang, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3720 - 3720
  • [48] Ultraviolet Ray Strength for Pre-irradiation in Gafchromic EBT2
    Katsuda, T.
    Gotanda, R.
    Gotanda, T.
    Akagawa, T.
    Tanki, N.
    Noguchi, A.
    Kuwano, T.
    Yabunaka, K.
    EMBEC & NBC 2017, 2018, 65 : 386 - 389
  • [49] IN VIVO DOSIMETRY BY EBT2 GAFCHROMIC FILMS TO VALIDATE A IORT PROCEDURE
    Magi, S.
    Romagnoli, R.
    Palombarini, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S12 - S12
  • [50] Dose and absorption spectra response of EBT2 Gafchromic film to high energy x-rays
    Butson, M. J.
    Cheung, T.
    Yu, P. K. N.
    Alnawaf, H.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (04) : 196 - 202