Method for increasing upper limit of heat flux measurement of slug calorimeter in high enthalpy plasma jet

被引:1
|
作者
Wang, Yuan [1 ,2 ]
Li, Xiaoping [1 ,2 ]
Liu, Donglin [1 ,2 ]
Liu, Yanming [1 ,2 ]
机构
[1] Xidian Univ, Sch Aerosp Sci & Technol, Xian 710071, Peoples R China
[2] Minist Educ China, Key Lab Informat & Struct Efficiency Extreme Envi, Xian 710071, Peoples R China
关键词
Experimental methods - Heat flux calculation - Heat flux measurement - Residence time - Steady state solution - Temperature changes - Thermodynamic characteristics - Transient solutions;
D O I
10.1063/5.0032749
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The temperature of the high-power inductively coupled plasma jet is very high, and its temperature is difficult to measure directly. The heat flux becomes a thermodynamic characteristic to measure the plasma jet. The existing heat flux calculation method is based on the temperature change rate after the response time. The slug is required to stay in the high enthalpy jet area for a longer time. With the slug temperature reaching the melting point as the upper limit, the shorter the residence time, the greater the upper limit of the measured heat flux. In this paper, the first-order transient solution is added to the steady-state solution of temperature (the calculation equation of the existing method), which can shorten the response time. The shortening of the response time can reduce the residence time of the slug in the jet region, and the reduction in the residence time can increase the upper limit of the calorimeter heat flux measurement. This paper uses numerical simulation and experimental methods to verify that the steady-state solution method and the first-order transient solution method can obtain consistent heat flux results. Using the first-order transient solution method can reduce the residence time of the slug calorimeter in the jet region. According to the shortening of the residence time, the method of using the first-order transient solution can increase the upper limit of the heat flux measurement by more than 25%.
引用
收藏
页数:8
相关论文
共 17 条
  • [1] Performance of Copper Calorimeter for Heat Transfer Measurement in High Enthalpy Shock Tunnel
    WANG Qiu
    LI Jiwei
    LI Jinping
    ZHAO Wei
    JIANG Zonglin
    Journal of Thermal Science, 2018, 27 (04) : 373 - 381
  • [2] Performance of Copper Calorimeter for Heat Transfer Measurement in High Enthalpy Shock Tunnel
    Qiu Wang
    Jiwei Li
    Jinping Li
    Wei Zhao
    Zonglin Jiang
    Journal of Thermal Science, 2018, 27 : 373 - 381
  • [3] Performance of Copper Calorimeter for Heat Transfer Measurement in High Enthalpy Shock Tunnel
    Wang Qiu
    Li Jiwei
    Li Jinping
    Zhao Wei
    Jiang Zonglin
    JOURNAL OF THERMAL SCIENCE, 2018, 27 (04) : 373 - 381
  • [4] Miniaturized heat flux sensor for high enthalpy plasma flow characterization
    Gardarein, Jean-Laurent
    Battaglia, Jean-Luc
    Loehle, Stefan
    Jullien, Pierre
    Van Ootegem, Bruno
    Couzi, Jacques
    Lasserre, Jean-Pierre
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2013, 21 (04) : 605 - 618
  • [5] PARIETAL HEAT-FLUX MEASUREMENT IN A NITROGEN PLASMA-JET
    CHERON, BG
    ROBIN, L
    VERVISCH, P
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (01) : 58 - 61
  • [6] Improvement of high heat flux measurement using a null-point calorimeter
    Loehle, Stefan
    Battaglia, Jean-Luc
    Jullien, Pierre
    van Ootegem, Brunb
    Couzi, Jacques
    Lasserre, Jean-Pierre
    JOURNAL OF SPACECRAFT AND ROCKETS, 2008, 45 (01) : 76 - 81
  • [7] Specific Heat Measurement of High Temperature Thermal Insulations by Drop Calorimeter Method
    T. Ohmura
    M. Tsuboi
    M. Onodera
    T. Tomimura
    International Journal of Thermophysics, 2003, 24 : 559 - 575
  • [8] Specific heat measurement of high temperature thermal insulations by drop calorimeter method
    Ohmura, T
    Tsuboi, M
    Onodera, M
    Tomimura, T
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2003, 24 (02) : 559 - 575
  • [9] MEASUREMENT OF THE TEMPERATURE-DEPENDENCE OF CARBON AND BERYLLIUM FLUXES IN THE JET BOUNDARY PLASMA USING A HIGH HEAT-FLUX PROBE
    SUMMERS, DDR
    ERENTS, K
    HUGON, M
    HWANG, A
    REBUT, PH
    REICHLE, R
    STAMP, MF
    STANGEBY, PC
    JOURNAL OF NUCLEAR MATERIALS, 1990, 176 : 593 - 599
  • [10] Optical method for erosion control of a cylinder placed in a high-enthalpy jet of plasma torch
    Kulikov Yu.M.
    Panov V.A.
    Saveliev A.S.
    Kardaev D.A.
    Gadzhiev M.Kh.
    Applied Physics, 2024, (03): : 26 - 30