Interference Effects of Cu(II) and Pb(II) on the Stripping Voltammetric Detection of Cd(II): Improvement in the Detection Precision and Interference Correction

被引:13
|
作者
Zhao, Guo [1 ,2 ]
Liu, Gang [1 ,2 ]
机构
[1] China Agr Univ, Key Lab Modern Precis Agr Syst Integrat Res, Minist Educ China, Beijing 100083, Peoples R China
[2] China Agr Univ, Key Lab Agr Informat Acquisit Technol, Minist Agr China, Beijing 100083, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
PARTICLE SWARM OPTIMIZATION; ARTIFICIAL NEURAL-NETWORKS; BISMUTH-FILM ELECTRODES; GLASSY-CARBON ELECTRODE; HEAVY-METAL IONS; ELECTROCHEMICAL DETECTION; REGRESSION-ANALYSIS; CADMIUM; MERCURY; DESIGN;
D O I
10.1149/2.0701809jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this study, a novel analytical method for the quantitative determination of Cd(II) under the interference of Pb(II) and Cu(II) via a combination of square-wave anodic stripping voltammetry (SWASV) and chemometric methods is proposed. In addition, this study focuses on the analysis of interference in the electroanalysis of Pb(II), Cd(II) and Cu(II) with an in situ bismuth film-modified glassy carbon electrode (Bi/GCE). In the presence of these mutual interferences, the chemometric methods considerably improved the resolution of the voltammetric technique. The chemometric methods, namely, a back-propagation artificial neural network (BP-ANN), a particle swarm optimization-support vector machine (PSO-SVM) and a ternary linear regression equation (TLRE), were used to determine the Cd(II) concentration under the interference of Cu(II) and Pb(II). The prediction performances of the different chemometric methods were verified in terms of their root mean square errors (RMSEs), average relative errors (AREs), mean absolute errors (MAEs), and correlation coefficients (R-2). The results indicate that the BP-ANN and PSO-SVM had higher prediction accuracies than the monadic linear regression equation (MLRE) and TLRE. Finally, the proposed method was used to determine the Cd(II) concentration in soil samples, with satisfactory results. (C) 2018 The Electrochemical Society.
引用
收藏
页码:H488 / H495
页数:8
相关论文
共 50 条
  • [1] Accurate SWASV detection of Cd(II) under the interference of Pb(II) by coupling support vector regression and feature stripping currents
    Liu, Ning
    Zhao, Guo
    Liu, Gang
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 889 (889)
  • [2] Anodic stripping voltammetric detection of Zn(II), Cd(II) and Pb(II) of coal gangue at bismuth film glassy carbon electrodes
    Wang, Xiu-Teng
    Zhang, Yajing
    Li, Xiaoyan
    Xu, Ling
    Lin, Ling
    Chen, Qian
    Yang, Shuo
    [J]. 3RD INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING, 2018, 113
  • [3] Crown ether-modified electrodes for the simultaneous stripping voltammetric determination of Cd(II), Pb(II) and Cu(II)
    Serrano, Nuria
    Gonzalez-Calabuig, Andreu
    del Valle, Manel
    [J]. TALANTA, 2015, 138 : 130 - 137
  • [4] Novel screen-printed antimony and tin voltammetric sensors for anodic stripping detection of Pb(II) and Cd(II)
    Maczuga, Mariola
    Economou, Anastasios
    Bobrowski, Andrzej
    Prodromidis, Mamas I.
    [J]. ELECTROCHIMICA ACTA, 2013, 114 : 758 - 765
  • [5] A diamond/graphite nanoplatelets electrode for anodic stripping voltammetric trace determination of Zn(II), Cd(II), Pb(II) and Cu(II)
    Zhai, Zhaofeng
    Huang, Nan
    Zhuang, Hao
    Liu, Lusheng
    Yang, Bing
    Wang, Chun
    Gai, Zhigang
    Guo, Fengxiang
    Li, Zhengjun
    Jiang, Xin
    [J]. APPLIED SURFACE SCIENCE, 2018, 457 : 1192 - 1201
  • [6] Antimony Film Electrode Prepared In Situ in Hydrogen Potassium Tartrate in Anodic Stripping Voltammetric Trace Detection of Cd(II), Pb(II), Zn(II), Tl(I), In(III) and Cu(II)
    Bobrowski, A.
    Putek, M.
    Zarebski, J.
    [J]. ELECTROANALYSIS, 2012, 24 (05) : 1071 - 1078
  • [7] A simple strategy for the detection of Cu(II), Cd(II) and Pb(II) in water by a voltammetric sensor on a TC4A modified electrode
    Liu, Lei
    Zhang, Ke
    Wei, Yumin
    [J]. NEW JOURNAL OF CHEMISTRY, 2019, 43 (03) : 1544 - 1550
  • [8] Modification of carbon screen-printed electrodes by adsorption of chemically synthesized Bi nanoparticles for the voltammetric stripping detection of Zn(II), Cd(II) and Pb(II)
    Granado Rico, Ma Angeles
    Olivares-Marin, Mara
    Pinilla Gil, Eduardo
    [J]. TALANTA, 2009, 80 (02) : 631 - 635
  • [9] Interesting interference evidences of electrochemical detection of Zn(II), Cd(II) and Pb(II) on three different morphologies of MnO2 nanocrystals
    Zhang, Qiao-Xin
    Wen, Hao
    Peng, Dai
    Fu, Qiang
    Huang, Xing-Jiu
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 739 : 89 - 96
  • [10] Stainless steel electrode for simultaneous stripping analysis of Cd(II), Pb(II), Cu(II) and Hg(II)
    Kitte, Shimeles Addisu
    Li, Suping
    Nsabimana, Anaclet
    Gao, Wenyue
    Lai, Jianping
    Liu, Zhongyuan
    Xu, Guobao
    [J]. TALANTA, 2019, 191 : 485 - 490