Three-phase four-wire shunt active filter to reduce voltage and current distortions in distribution systems

被引:0
|
作者
De Camargo, Robinson Figueiredo [1 ]
Pinheiro, Humberto [2 ]
机构
[1] Univ Reg Noroeste Estado Rio Grande do Sul, Dept Tecnol, Grupo Automacao Ind & Controle, Rua Sao Francisco, Ijui, RS, Brazil
[2] Univ Fed Santa Maria, Ctr Tecnol, Power Elect & Control Res Grp, BR-97119900 Santa Maria, RS, Brazil
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a shunt active filter (SAF) to reduce voltage distortions, caused by resonances between capacitances and inductances on three-phase four-wire low-voltage power distribution system, to below the recommended level by IEEE Std. 519-1992. In addition, there is a reduction of neutral currents caused by non-linear loads in this system. A detailed analysis of the normalized discrete model of the SAF is presented considering its implementation in a DSP TMS320F2812. Furthermore, the extension of the voltage detection method and the deadbeat current control applied to four-wire systems are proposed. Finally, experimental results are presented from a 20 kVA operating prototype, demonstrating performance in terms of voltage harmonic compensation at the point of common connection and the neutral current reduction.
引用
收藏
页码:1353 / +
页数:2
相关论文
共 50 条
  • [1] Design of Single-Phase Shunt Active Filter for Three-Phase Four-Wire Distribution Systems
    Hou, Chung-Chuan
    Huang, Yung-Fu
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 1525 - 1528
  • [2] The Study of Three-Phase Four-Wire Shunt Active Power Filter
    Huang, Hai-hong
    Xu, Ruo-bing
    Wang, Hai-xin
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 3496 - 3499
  • [3] Simulation of three-phase four-wire shunt active power filter
    Wang, Ji-Dong
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2007, 40 (SUPPL.): : 95 - 99
  • [4] Three-phase four-wire shunt active filter control strategies
    Aredes, M
    Hafner, J
    Heumann, K
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) : 311 - 318
  • [5] Shunt active filter with three-phase four-wire NPC inverter
    Lin, BR
    Chiang, HK
    Yang, KT
    2004 47TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, CONFERENCE PROCEEDINGS, 2004, : 281 - 284
  • [6] A Control Strategy for a Three-Phase Four-Wire Shunt Active Filter
    Ferreira, Filipe
    Monteiro, Luis
    Afonso, Joao L.
    Couto, Carlos
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 360 - 365
  • [7] Simulation of Three-phase Four-wire Shunt Active Power Filter
    Wang, Jidong
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1702 - 1705
  • [8] A shunt active filter for compensating harmonics and unbalance in three-phase four-wire systems
    Aboutaleb, Abdellatif M.
    Azazi, Haitham Z.
    Osheba, Dina S. M.
    El-Sabbe, Awad E.
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2020, 107 (08) : 1195 - 1215
  • [9] A shunt active filter control for one-phase and three-phase four-wire systems
    Dell'Aquila, A
    Lecci, A
    ISIE 2002: PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1-4, 2002, : 1301 - 1305
  • [10] Control Strategy of DC Voltage in Three-Phase Four-Wire Shunt Active Power Filter
    Wei, Xueliang
    Liang, Zhishan
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2036 - +