The Design of Current Probe in the IEC Conducted Emission Measurement above 1 GHz

被引:0
|
作者
Chang, Yin-Cheng [1 ,2 ]
Lin, Ta-Yeh [2 ]
Wang, Ping-Yi [1 ]
Hsu, Shawn S. H. [1 ]
Yen, Mao-Hsu [3 ]
Chang, Yen-Tang [4 ]
Lin, Ming-Shan [4 ]
Chang, Da-Chiang [2 ]
机构
[1] Natl Tsing Hua Univ, Inst Elect Engn, Hsinchu, Taiwan
[2] Natl Chip Implementat Ctr, Natl Appl Res Labs, Hsinchu, Taiwan
[3] Natl Taiwan Ocean Univ, Dept Comp Sci & Engn, Keelung, Taiwan
[4] MOEA, Bur Stand Metrol & Inspect, Taipei, Taiwan
关键词
EMC; EMI; conducted emission; current probe; measurement;
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
A current probe based on IEC standard 61967-4 is proposed to investigate the conducted electromagnetic emission of IC above 1 GHz. The 1 Omega method in direct coupling method is revisited, and the concern for extending frequency range is discussed. The critical resistive network of 1 Omega probe is realized by a semiconductor process instead of the SMD resistors. With the advantage of reduced parasitic effect, the applicable bandwidth can be extended to 2.4 GHz. The proposed 1 Omega probe is verified to fulfill the EMI measurement of IC with operating frequency higher than 1 GHz.
引用
收藏
页码:938 / 939
页数:2
相关论文
共 50 条
  • [1] Validation of emission measurement site above 1 GHz
    Tosaka, Toshihide
    Yamanaka, Yukio
    RADIO SCIENCE, 2011, 46
  • [2] Emission measurement in frequency range above 1 GHz
    Zimmermann, Krzysztof
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (09): : 24 - 26
  • [3] Investigation of radiated emission measurement method above 1 GHz
    Miyazaki, Chiharu
    Igarashi, Yoichi
    Endo, Kiyoshi
    Satake, Shozo
    Kawano, Jiro
    2007 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY: WORKSHOP AND TUTORIAL NOTES, VOLS 1-3, 2007, : 1201 - +
  • [4] Implementation of Certified 150-Ω Voltage Probe for IEC 61967-4 Conducted Electromagnetic Emission Measurement
    Chang, Yin-Cheng
    Lin, Ta-Yeh
    Wang, Ping-Yi
    Hsu, Shawn S. H.
    Yen, Mao-Hsu
    Hung, Chun-Yi
    Chang, Da-Chiang
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [5] Site Contributions for Radiated Emission Measurement Uncertainties above 1 GHz
    Chen, Zhong
    Xiong, Zubiao
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & SIGNAL/POWER INTEGRITY (EMCSI), 2017, : 504 - 509
  • [6] A Novel Broadband High Sensitivity Current Probe Design and Analysis for Conducted Emission Testing
    Sha Miao
    Teng Wanxiu
    Song Gang
    Mu Xiaotong
    Shang Baoying
    Song Jilei
    Lv Dongxiang
    2018 INTERNATIONAL CONFERENCE OF GREEN BUILDINGS AND ENVIRONMENTAL MANAGEMENT (GBEM 2018), 2018, 186
  • [7] Current Probes for Differential Mode Conducted Emission Measurement
    Knight, D. A.
    Marshall, R. C.
    2017 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2017,
  • [8] Measurement Validation for the Extension of Emission Measurements in Alternative Test Sites Above 1 GHz
    Menssen, Benjamin
    Brech, Henrik
    Garbe, Heyno
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2016, 58 (04) : 1274 - 1281
  • [9] The evaluation for emission measurements above 1GHz
    Li, X
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS: CEEM'2000, PROCEEDINGS, 2000, : 422 - 426
  • [10] Subjects of discussion in radiated emission measurements above 1 GHz
    Battermann, S.
    Garbe, H.