Application of germline IGH probes in real-time quantitative PCR for the detection of minimal residual disease in acute lymphoblastic leukemia

被引:161
|
作者
Verhagen, OJHM
Willemse, MJ
Breunis, WB
Wijkhuijs, AJM
Jacobs, DCH
Joosten, SA
van Wering, ER
van Dongen, JJM
van der Schoot, CE
机构
[1] Erasmus Univ, Dept Immunol, Med Ctr, NL-3000 DR Rotterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Expt & Clin Immunol Lab, NL-1105 AZ Amsterdam, Netherlands
[3] Netherlands Red Cross, Blood Transfus Serv, Cent Lab, Dept Immunohematol, Amsterdam, Netherlands
[4] Dutch Childhood Leukemia Study Grp, The Hague, Netherlands
[5] Univ Amsterdam, Acad Med Ctr, Dept Hematol, NL-1105 AZ Amsterdam, Netherlands
关键词
acute lymphoblastic leukemia (ALL); IGH gene rearrangements; real-time quantitative PCR (RQ-PCR); minimal residual disease (MRD); germline J(H) TaqMan probes;
D O I
10.1038/sj.leu.2401801
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Large-scale clinical studies on detection of minimal residual disease (MRD) in acute lymphoblastic leukemia (ALL) have shown that quantification of MRD levels is needed for reliable MRD-based risk group classification. Recently, we have shown that 'real-time' quantitative PCR (RQ-PCR) can be applied for this purpose using patient-specific immunoglobulin (Ig) and T cell receptor (TCR) gene rearrangements as PCR targets with TaqMan probes at the position of the junctional region and two germline primers. Now, we tested an alternative approach on 35 immunoglobulin heavy chain (IGH) gene rearrangements, by designing three germline J(H) TaqMan probes to be used in combination with one of six corresponding germline J(H) primers and one allele specific oligonucleotide (ASO) primer complementary to the junctional region. In nine cases in which both approaches were compared, at least similar (n = 4) or slightly higher (n = 5) maximal sensitivities were obtained using an ASO primer. The ASO primer approach reached maximal sensitivities of at least 10(-4) in 33 out of 35 IGH rearrangements. The reproducible range for accurate quantification spanned four to five orders of magnitude in 31 out of 35 cases. In 13 out of 35 rearrangements the stringency of PCR conditions had to be increased to remove or diminish background signals; this only concerned the frequently occurring J(H)4, J(H)5 and J(H)6 gene rearrangements. After optimization of the conditions (mainly by increasing the annealing temperature), only occasional aspecific amplification signals were observed at high threshold cycle (C-T) values above 42 cycles and at least six cycles above the C-T value of the detection limit. Hence, these rare aspecific signals could be easily discriminated from specific signals. We conclude that the here presented set of three germline J(H) TaqMan probes and six corresponding germline J(H) primers can be used to develop patient-specific RQ-PCR assays, which allow accurate and sensitive MRD analysis in almost all IGH gene rearrangements. These results will facilitate standardized RQ-PCR analysis for MRD detection in large clinical studies.
引用
收藏
页码:1426 / 1435
页数:10
相关论文
共 50 条
  • [1] Application of germline IGH probes in real-time quantitative PCR for the detection of minimal residual disease in acute lymphoblastic leukemia
    OJHM Verhagen
    MJ Willemse
    WB Breunis
    AJM Wijkhuijs
    DCH Jacobs
    SA Joosten
    ER van Wering
    JJM van Dongen
    CE van der Schoot
    [J]. Leukemia, 2000, 14 : 1426 - 1435
  • [2] Minimal residual disease detection in acute lymphoblastic leukemia: Real improvement with the real-time quantitative PCR method?
    Neale, GAM
    Campana, D
    Pui, CH
    [J]. JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2003, 25 (02) : 100 - 102
  • [3] Real-time quantitative of minimal residual PCR: Standardized detection disease in pediatric acute lymphoblastic leukemia
    Pine, SR
    Moy, FH
    Wiemels, JL
    Gill, RK
    Levendoglu-Tugal, O
    Ozkaynak, MF
    Sandoval, C
    Jayabose, S
    [J]. JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2003, 25 (02) : 103 - 108
  • [4] Real-time quantitative PCR for the detection of minimal residual disease in acute lymphoblastic leukemia using junctional region specific TaqMan probes
    MJ Pongers-Willemse
    OJHM Verhagen
    GJM Tibbe
    AJM Wijkhuijs
    V de Haas
    E Roovers
    CE van der Schoot
    JJM van Dongen
    [J]. Leukemia, 1998, 12 : 2006 - 2014
  • [5] Real-time quantitative PCR for the detection of minimal residual disease in acute lymphoblastic leukemia using junctional region specific TaqMan probes
    Pongers-Willemse, MJ
    Verhagen, OJHM
    Tibbe, GJM
    Wijkhuijs, AJM
    de Haas, V
    Roovers, E
    van der Schoot, CE
    van Dongen, JJM
    [J]. LEUKEMIA, 1998, 12 (12) : 2006 - 2014
  • [6] Real-time PCR for quantitative detection of minimal residual disease (MRD) in childhood acute lymphoblastic leukemia (ALL)
    Pongers-Willemse, MJ
    Verhagen, OJHM
    Tibbe, GJM
    Wijkhuijs, JM
    De Haas, V
    Van Wering, ER
    Van der Schoot, CE
    Van Dongen, JJM
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 292 - 292
  • [7] Quantitative fluorescent PCR for minimal residual disease detection in childhood acute lymphoblastic leukemia
    Kahrisangi, RS
    Salehi, M
    Mousazadeh, M
    Sabahi, AR
    [J]. LEUKEMIA, 2003, 17 (03) : 673 - 673
  • [8] Detection and monitoring of minimal residual disease by quantitative real-time PCR
    Schüler, F
    Dölken, G
    [J]. CLINICA CHIMICA ACTA, 2006, 363 (1-2) : 147 - 156
  • [9] T cell receptor gamma gene rearrangements as targets for detection of minimal residual disease in acute lymphoblastic leukemia by real-time quantitative PCR analysis
    VHJ van der Velden
    JM Wijkhuijs
    DCH Jacobs
    ER van Wering
    JJM van Dongen
    [J]. Leukemia, 2002, 16 : 1372 - 1380
  • [10] T cell receptor gamma gene rearrangements as targets for detection of minimal residual disease in acute lymphoblastic leukemia by real-time quantitative PCR analysis
    van der Velden, VHJ
    Wijkhuijs, JM
    Jacobs, DCH
    van Wering, ER
    van Dongen, JJM
    [J]. LEUKEMIA, 2002, 16 (07) : 1372 - 1380