Spatial Tissue Oxygenation Measurement with near Infra-Red Spectroscopy using a Virtual Instrument

被引:0
|
作者
Sun, J. W. [1 ]
Zhang, Y. [1 ]
Rolfe, P. [1 ,2 ,3 ,4 ]
Scopesi, F. [2 ]
Serra, G. [2 ]
Wei, G. [1 ,3 ]
机构
[1] Harbin Inst Technol, Harbin, Peoples R China
[2] Univ Genoa, I-16126 Genoa, Italy
[3] Harbin Inst Technol, Harbin, Peoples R China
[4] Waseda Univ, Oxford BioHorizons Ltd, Tokyo, Japan
关键词
NIRS; Tissue Oxygenation; diffuse reflectance; Lambert-Beer Law;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe near infrared spectroscopy (NIRS) to study spatial variations in tissue oxygenation: oxyhaemoglobin (HbO(2)); deoxy-haemoglobin (HHb); and total haemoglobin (Hb(tot)). Apparatus was constructed incorporating light-emitting diodes (LED) as the light sources, sensitive photodiodes (PD) as the detectors, a virtual instrument to control the opto devices and collect and process the signals. The MATLAB script was embedded into LABVIEW to process and display the data. Changes in chromophore concentration were calculated using the modified Lambert-Beer Law together with the diffusion theory. We attached an LED array on the volar surface of the adult forearm with a PD detector placed at various distances of 12 to 40 mm from the sources. Further studies were performed in adults with forearm blood volume and oxygenation manipulated by venous and arterial occlusion respectively. Results indicated that source-detector spacing can achieve spatial sensitivity of blood volume and blood oxygenation measurement. The in vivo results demonstrated that the methodology and equipment achieved good performance as expected. In addition, we used dye-scatterer phantom to analyze the optical properties of near-infrared spectroscopy, where a spectrophotometer was used to calibrate the performance of the instrument. The in vitro results showed good correlation between the new instrument and the laboratory standard. The virtual instrument was a flexible and convenient means to develop apparatus for in vivo NIRS measurement. Spatial changes in tissue blood volume and oxygenation could be useful for clinical and research applications.
引用
收藏
页码:320 / +
页数:2
相关论文
共 50 条
  • [1] Design of a Portable Near Infra-Red Spectroscopy System for Tissue Oxygenation Measurement
    Zhang, Y.
    Sun, J. W.
    Wei, G.
    Scopesi, F.
    Serra, G.
    Rolfe, P.
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2819 - +
  • [2] A low cost instrument for in vivo near infra-red spectroscopy
    Rolfe, P
    Bottini, F
    Mondo, G
    Repetto, D
    Ruggiero, C
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 454 - 455
  • [3] Tissue oxygenation-monitoring using Near Infra Red Spectroscopy
    Oeseburg, B
    PHYSIOLOGY AND PHARMACOLOGY OF CARDIO-RESPIRATORY CONTROL, 1998, : 25 - 31
  • [4] Near infra-red spectroscopy
    Fearn, SJ
    Mead, GE
    Picton, AJ
    Mortimer, AJ
    McCollum, CN
    ANAESTHESIA, 1996, 51 (08) : 800 - 800
  • [5] DIFFERENCE SPECTROSCOPY IN THE NEAR INFRA-RED
    WILLIS, HA
    MILLER, RGJ
    SPECTROCHIMICA ACTA, 1959, 14 (JAN): : 119 - 126
  • [6] A REVIEW OF NEAR INFRA-RED SPECTROSCOPY
    Donnelly, Peter
    Fine-Goulden, Miriam
    ARCHIVES OF DISEASE IN CHILDHOOD, 2019, 104 : A180 - A181
  • [7] Influence of probe geometry on the sensitivity of tissue oximeter using near infra-red spectroscopy
    Wang, Feng
    Ding, Haishu
    Lin, Fang
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2000, 20 (04): : 585 - 588
  • [8] The influence of probe geometry on the sensitivity of tissue oximeter using near infra-red spectroscopy
    Wang, F
    Ding, HS
    Lin, F
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2000, 20 (04) : 585 - 588
  • [9] Non-Invasive Blood Glucose Measurement Using Near Infra-Red Spectroscopy
    Priyoti, Anika Tabassum
    Jim, Salman Jubair
    Hossain, Sushmit
    Mahmud, Shafkat
    Salvin, Sujana
    Bhattacharjee, Arnab
    PROCEEDINGS OF 2019 IEEE R10 HUMANITARIAN TECHNOLOGY CONFERENCE (IEEE R10 HTC 2019), 2019, : 1 - 4
  • [10] Measurement of cerebral oxygenation during oxygen challenge in chronic obstructive pulmonary disease (COPD) using near infra-red spectroscopy
    McGown, AD
    Valipour, A
    Makker, H
    Spiro, SG
    THORAX, 2000, 55 : A41 - A41