Impact of the Coarse Indoor Non-radioactive Aerosols on the Background Radon Progenies' Compensation of a Continuous Air Monitor

被引:4
|
作者
Hoarau, Gwenael [1 ]
Dougniaux, Gregoire [1 ]
Gensdarmes, Francois [1 ]
Cassette, Philippe [2 ]
Ranchoux, Gilles [3 ]
机构
[1] Inst Radioprotect & Surete Nucl IRSN, Lab Phys & Merol Aerosols LPMA, SCA, PSN Res, F-91192 Gif Sur Yvette, France
[2] Commissariat Energie Atom & Energies Alternat CEA, LIST, Lab Natl Henri Becquerel LNE LNHB, F-91191 Saclay, France
[3] Elecricite France EDF, Direct Projets Deconstruct Dechets DP2D, F-69006 Lyon, France
来源
HEALTH PHYSICS | 2022年 / 122卷 / 05期
关键词
aerosols; monitors; radiation; nuclear power plant; background; ALPHA; PERFORMANCE; CALIBRATION;
D O I
10.1097/HP.0000000000001530
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper addresses the problem of false positive alarm when using a continuous air monitor (CAM) in decommissioning sites of nuclear facilities. CAMs are used to measure airborne activity and play an important role in the radiation protection of workers likely to be exposed to radioactive aerosols. Monitors usually sample aerosols on a membrane filter. Radioactive particles sampled are detected through the alpha and beta decays that they emit. These latter ionizing particles are measured online by spectrometry thanks to a Passivated Implanted Planar Silicon detector (PIPS). Alpha and beta decays, in this context, come mainly from the natural radon progeny (Po-218, Pb-214, and so on) and, in the case of radioactive contamination, also from artificial radionuclides such as Pu-239 or Cs-137. The aim of the CAM is to alert the workers when the artificial airborne activity occurs, always considering the presence of a variable background due to the natural particulate airborne activity. The CAM-specific algorithm considers this background dynamically and continuously, often by using a constant parameter. However, non-radioactive aerosols are also sampled on the membrane filter. These latter make the discrimination more difficult as they lead to the deterioration of the alpha-energy spectrum. In this paper, the effect of coarse non-radioactive aerosols on the CAM response is highlighted with four aerosol size-distributions. The evolution of the background is characterized as a function of the aerosol mass sampled, with the example of a simple algorithm. Thus, in this paper, results show a positive correlation of the background with the aerosol mass sampled by the CAM. In addition, results highlight at least two different evolutionary trends according to the aerosol size distribution. An explanation of these evolutions is given by considering the penetration profile of the natural radioactive aerosols in the granular deposit above the CAM filter. The main consequence of these results is that the background could not be considered as proportional to radon progeny as it is currently used.
引用
收藏
页码:563 / 574
页数:12
相关论文
共 2 条
  • [1] EVALUATION OF NATURAL EXPOSURE DUE TO INHALATION OF RADIOACTIVE AEROSOLS OF RADON DAUGHTER PRODUCTS IN INDOOR AIR
    RANNOU, A
    MOUDEN, A
    TYMEN, G
    JOURNAL OF AEROSOL SCIENCE, 1988, 19 (01) : 27 - 32
  • [2] Development of an in-situ continuous air monitor for the measurement of highly radioactive alpha-emitting particulates (a-aerosols) under high humidity environment
    Tsubota, Youichi
    Honda, Fumiya
    Tokonami, Shinji
    Tamakuma, Yuki
    Nakagawa, Takahiro
    Ikeda-Ohno, Atsushi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1030