Energy performance assessment of thermo-active micro-piles via numerical modeling and statistical analysis

被引:16
|
作者
Cecinato, Francesco [1 ]
Salciarini, Diana [2 ]
机构
[1] Univ Milan, Dipartimento Sci Terra A Desio, Via Mangiagalli 34, I-20133 Milan, Italy
[2] Univ Perugia, Dept Civil & Environm Engn, Via G Duranti 93, I-06125 Perugia, Italy
关键词
Hueckel; Energy foundations; Numerical modeling; Micropiles; Shallow geothermal energy; Retrofitting; DIFFERENT DESIGN; HEAT; CONDUCTIVITY; BEHAVIOR; PROTOTYPE; CONCRETE; STORAGE;
D O I
10.1016/j.gete.2021.100268
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Energy micro-piles (EMPs) constitute a promising emerging technology, able to provide both energy and structural retrofitting to existing buildings. Although a number of studies have been published on the energy performance of standard energy piles (EPs), bespoke analysis is required for EMPs due to their different geometry and peculiar design and site constraints. In this work, a parametric study is carried out by means of numerical Finite Element simulations complemented by statistical analysis, aimed at identifying the dominant parameters in maximizing EMP thermal efficiency. Two categories of parameters, namely design-dependent and site-dependent ones, are separately considered to provide guidance for practitioners on both detailed geothermal sizing and overall feasibility assessment. The parameter space is efficiently explored resorting to Taguchi Experimental Design statistical tools. Results show that different design criteria to those for EPs should be used for EMPs. Notably for the latter, contrary to the former, the diameter of heat exchanger pipes emerges as one of the most important factors promoting thermal efficiency, while being the single easiest parameter to engineer. On the other hand, while maximizing the number of U-pipes and pile diameter is crucial for EPs, it does not impact the energy performance of EMPs, due to geometry constraints and the expected occurrence of thermal interferences. Among site-dependent factors, a large ground thermal conductivity is confirmed as an important feature to ensure a high energy performance, while interesting insights are obtained about the role of basement thermal insulation in the long-term EMP thermal output.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Numerical modelling of thermo-active piles in London Clay
    Gawecka, Klementyna A.
    Taborda, David M. G.
    Potts, David M.
    Cui, Wenjie
    Zdravkovic, Lidija
    Kasri, Muhamad S. Haji
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GEOTECHNICAL ENGINEERING, 2017, 170 (03) : 201 - 219
  • [2] Experimental and numerical investigations on the energy performance of a thermo-active tunnel
    Insana, A.
    Barla, M.
    RENEWABLE ENERGY, 2020, 152 : 781 - 792
  • [3] A simplified methodology for determining the thermal performance of thermo-active piles
    Liu, Ryan Yin Wai
    Taborda, David M. G.
    ENVIRONMENTAL GEOTECHNICS, 2023,
  • [4] Long-Term Thermo-Hydraulic Numerical Assessment of Thermo-Active Piles-A Case of Tropical Soils
    Zhang, Jiamin
    Dias, Daniel
    Pan, Qiujing
    Ma, Chunjing
    Tsuha, Cristina de Hollanda Cavalcanti
    APPLIED SCIENCES-BASEL, 2022, 12 (15):
  • [5] Micro-piles under dynamic horizontal excitation: Field tests and numerical modeling
    Meier, Thomas
    NUMERICAL METHODS IN GEOTECHNICAL ENGINEERING, VOL 1, 2014, : 181 - 186
  • [6] Energy performance evaluation of thermo-active building system based on simulation and measurement
    Muramatsu H.
    Togashi E.
    Nobe T.
    Journal of Environmental Engineering (Japan), 2019, 84 (762): : 759 - 769
  • [7] Analysis of thermo-active pile structures and their performance under groundwater flow conditions
    Gashti, E. Hassani Nezhad
    Malaska, M.
    Kujala, K.
    ENERGY AND BUILDINGS, 2015, 105 : 1 - 8
  • [8] Primary energy and comfort performance of ventilation assisted thermo-active building systems in continental climates
    Henze, Gregor P.
    Felsmann, Clemens
    Kalz, Doreen E.
    Herkel, Sebastian
    ENERGY AND BUILDINGS, 2008, 40 (02) : 99 - 111
  • [9] Thermo-mechanical analysis of energy piles through numerical and centrifuge tests
    Rotta Loria, Alessandro F.
    Di Donna, Alice
    Laloui, Lyesse
    FROM FUNDAMENTALS TO APPLICATIONS IN GEOTECHNICS, 2015, : 793 - 800
  • [10] Experimental and Numerical Investigations on Performance of Screw Micro-Piles under Pull-out and Lateral Loads (Dec, 10.1080/19386362.2024.2437466, 2024)
    Karami, M.
    Basack, S.
    Pan, M.
    Das, G.
    Gupta, A.
    Karakouzian, M.
    INTERNATIONAL JOURNAL OF GEOTECHNICAL ENGINEERING, 2025, 19 (1-3) : 138 - 138