Ferrocenyl silicon-based dendrimers as mediators in amperometric biosensors

被引:70
|
作者
Losada, J [1 ]
Cuadrado, I [1 ]
Moran, M [1 ]
Casado, CM [1 ]
Alonso, B [1 ]
Barranco, M [1 ]
机构
[1] UNIV AUTONOMA MADRID,FAC CIENCIAS,DEPT QUIM INORGAN,MADRID 28049,SPAIN
关键词
biosensors; amperometry; dendrimers; ferrocenes; glucose;
D O I
10.1016/S0003-2670(96)00462-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of ferrocene-containing dendrimers as mediators in amperometric biosensors is described. The steady-state amperometric response of carbon paste electrodes containing these dendritic relay systems and glucose oxidase is investigated as a function of the glucose concentration and the applied potential. The results show that these sensors respond rapidly to the addition of glucose. The dependence of the glucose sensor response on the size, the number of organometallic redox centers and the nature of the organosilicon dendritic framework is discussed.
引用
收藏
页码:191 / 198
页数:8
相关论文
共 50 条
  • [1] Ferrocenyl and permethylferrocenyl cyclic and polyhedral siloxane polymers as mediators in amperometric biosensors
    Losada, J
    Armada, MPG
    Cuadrado, I
    Alonso, B
    González, B
    Casado, CM
    Zhang, J
    JOURNAL OF ORGANOMETALLIC CHEMISTRY, 2004, 689 (17) : 2799 - 2807
  • [2] Silicon-based dendrimers
    Frey, H
    Schlenk, C
    DENDRIMERS II: ARCHITECTURE, NANOSTRUCTURE AND SUPRAMOLECULAR CHEMISTRY, 2000, 210 : 69 - 129
  • [3] Silicon-based dendrimers
    Lukevics, E
    Arsenyan, P
    Pudova, O
    MAIN GROUP METAL CHEMISTRY, 2002, 25 (03) : 135 - 154
  • [4] Application of mass fabricated silicon-based gold transducers for amperometric biosensors
    Ziolkowski, Robert
    Gorski, Lukasz
    Zaborowski, Michal
    Malinowska, Elzbieta
    BIOELECTROCHEMISTRY, 2010, 80 (01) : 31 - 37
  • [5] Silicon-based ferrocenyl dendrimers as anion receptors in solution and immobilized onto electrode surfaces
    Depto. de Quim. Inorgánica, Fac. de Cie., Univ. Auton. de Madrid, Cantoblanco 28049-Madrid, Spain
    不详
    J Electroanal Chem, 1 (87-92):
  • [6] Silicon-based ferrocenyl dendrimers as anion receptors in solution and immobilized onto electrode surfaces
    Casado, CM
    Cuadrado, I
    Alonso, B
    Morán, M
    Losada, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 463 (01): : 87 - 92
  • [7] Amperometric biosensors based on redox polymers as mediators
    Okamoto, Y
    Kakul, T
    Karan, HI
    Hale, PD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 57 - IEC
  • [8] Porous silicon-based biosensors.
    Ghadiri, MR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U162 - U162
  • [9] Novel concepts for silicon-based biosensors
    Schöning, MJ
    Lüth, H
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2001, 185 (01): : 65 - 77
  • [10] POLYFERROCENES AS MEDIATORS IN AMPEROMETRIC BIOSENSORS FOR GLUCOSE
    HENDRY, SP
    CARDOSI, MF
    TURNER, APF
    NEUSE, EW
    ANALYTICA CHIMICA ACTA, 1993, 281 (03) : 453 - 459