CRISPR/Cas12a-Enhanced Loop-Mediated Isothermal Amplification for the Visual Detection of Shigella flexneri

被引:16
|
作者
Shi, Yaoqiang [1 ]
Kang, Lan [1 ]
Mu, Rongrong [1 ]
Xu, Min [1 ]
Duan, Xiaoqiong [1 ]
Li, Yujia [1 ]
Yang, Chunhui [1 ]
Ding, Jia-Wei [2 ]
Wang, Qinghua [3 ]
Li, Shilin [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Inst Blood Transfus, Provincial Key Lab Transfus Transmitted Infect Di, Chengdu, Peoples R China
[2] Kunming Med Univ, Clin Lab Dept, Yanan Hosp, Kunming, Yunnan, Peoples R China
[3] Tradit Chinese Med Hosp, Dept Emergency, Chengdu, Peoples R China
关键词
CRISPR; Cas12a; loop-mediated isothermal amplification; Shigella flexneri; point of care test; visual detection; IDENTIFICATION; SYSTEM; RNA;
D O I
10.3389/fbioe.2022.845688
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Shigella flexneri is a serious threat to global public health, and a rapid detection method is urgently needed. The CRISPR/Cas (clustered regularly interspaced short palindromic repeats/CRISPR-associated) system is widely used in gene editing, gene therapy, and in vitro diagnosis. Here, we combined loop-mediated isothermal amplification (LAMP) and CRISPR/Cas12a to develop a novel diagnostic test (CRISPR/Cas12a-E-LAMP) for the diagnosis of S. flexneri. The CRISPR/Cas12a-E-LAMP protocol conducts LAMP reaction for S. flexneri templates followed by CRISPR/Cas12a detection of predefined target sequences. LAMP primers and sgRNAs were designed to the highly conserved gene hypothetical protein (accession: AE014073, region: 4170556-4171,068) of S. flexneri. After the LAMP reaction at 60 degrees C for 20 min, the pre-loaded CRISPR/Cas12a regents were mixed with the LAMP products in one tube at 37 degrees C for 20 min, and the final results can be viewed by naked eyes with a total time of 40 min. The sensitivity of CRISPR/Cas12a-E-LAMP to detect S. flexneri was 4 x 10(0) copies/mu l plasmids and without cross-reaction with other six closely related non-S. flexneri. Therefore, the CRISPR/Cas12a-E-LAMP assay is a useful method for the reliable and quick diagnosis of S. flexneri and may be applied in other pathogen infection detection.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Research of a loop-mediated isothermal amplification assay for detection of Shigella bacteria
    College of Life Sciences of China Jiliang University, Hangzhou 310018, China
    [J]. J. Chin. Inst. Food Sci. Technol., 2013, 8 (200-206):
  • [2] Loop-mediated Isothermal Amplification Method for Rapid Detection of Shigella dysenteriae
    Zhong, Qingping
    Wang, Li
    Wang, Bin
    Chen, Hongyuan
    [J]. MEDICAL MATERIALS AND ENGINEERING, 2012, 140 : 369 - +
  • [3] Visual detection of mycobacterium tuberculosis by loop-mediated isothermal amplification
    Aryan, Ehsan
    Neshani, Alireza
    Sadeghian, Hamid
    Safdari, Hadi
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [4] Development of a loop-mediated isothermal amplification assay for molecular serotyping of Shigella flexneri Serotypes 2 and Xv
    Li, Sha
    Ji, Shunshi
    Zhu, Xiong
    Chen, Hai
    Jin, Dong
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2022, 132 (04) : 2980 - 2989
  • [5] WarmStart colorimetric loop-mediated isothermal amplification for the one-tube, contamination-free and visualization detection of Shigella flexneri
    Shi, Yaoqiang
    Xu, Min
    Duan, Xiaoqiong
    Li, Shilin
    Ding, Jia-wei
    Chen, Limin
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2021, 112 : 55 - 62
  • [6] Sensitive and Visual Detection of Brassica Yellows Virus Using Reverse Transcription Loop-Mediated Isothermal Amplification-Coupled CRISPR-Cas12 Assay
    Xu, Tengzhi
    Yang, Xiaolan
    Feng, Xia
    Luo, Hao
    Luo, Chun
    Jia, Meng-Ao
    Lei, Lei
    [J]. PHYTOPATHOLOGY, 2024, 114 (02) : 474 - 483
  • [7] CRISPR/Cas12a coupled with loop-mediated isothermal amplification and lateral flow assay for SARS-CoV-2 detection
    Wang, Yuer
    Peng, Yadan
    Liu, Sitong
    Li, Mengzhe
    Pei, Xiaojing
    Tong, Yigang
    [J]. ANALYTICAL METHODS, 2024, 16 (35) : 5971 - 5981
  • [8] A loop-mediated isothermal amplification assay for the visual detection of duck circovirus
    Xie, Liji
    Xie, Zhixun
    Zhao, Guangyuan
    Liu, Jiabo
    Pang, Yaoshan
    Deng, Xianwen
    Xie, Zhiqin
    Fan, Qing
    Luo, Sisi
    [J]. VIROLOGY JOURNAL, 2014, 11
  • [9] A loop-mediated isothermal amplification assay for the visual detection of duck circovirus
    Liji Xie
    Zhixun Xie
    Guangyuan Zhao
    Jiabo Liu
    Yaoshan Pang
    Xianwen Deng
    Zhiqin Xie
    Qing Fan
    Sisi Luo
    [J]. Virology Journal, 11
  • [10] Loop-mediated isothermal amplification (LAMP)/Cas12a assay for detection of Ralstonia solanacearum in tomato
    Fan, Zhiyu
    Mei, Yuxia
    Xing, Jiawei
    Chen, Tian
    Hu, Di
    Liu, Hui
    Li, Yingjun
    Liu, Derui
    Liu, Zufeng
    Liang, Yunxiang
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11