Accuracy of EEG dipole source localisation in presence of brain lesions

被引:0
|
作者
Vatta, F [1 ]
Bruno, P [1 ]
Inchingolo, P [1 ]
机构
[1] Univ Trieste, Elect Elect & Comp Sci Dept, I-34127 Trieste, Italy
关键词
source localisation; volume conductor model; brain lesions; inhomogeneity; EEG;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inverse solution techniques based on electroencephalographic (EEG) measurements are a powerful mean of gaining knowledge about brain functioning, being used to estimate location, orientation and strength of neural electrical sources of brain activity. A model of the head, a model of the source and an electric-field computational method are necessary to describe the EEG problem mathematically. Volume conductor models commonly used to describe the EEG neglect the presence of brain lesions. We evaluated the need of considering brain lesions in head models for precise mapping of neural activity nearby the lesion, as it is requested for neurosurgical preoperative planning. A systematic evaluation of the effects of neglecting brain lesions in EEG dipole source localisation accuracy has been performed by computer simulations for different pathologic conditions, source types and source positions. Simulations A EEG measurements were carried out using a modified eccentric-spheres model of the head in which m eccentric bubble approximates effects of actual brain lesions. A three concentric spheres model has been used in the inverse dipole fitting procedure to quantify source localisation errors caused by ignoring the presence of lesions in the head model. 64 different situations have been analysed. Source reconstruction errors resulted negligible only for some relative positions of source, lesion and electrodes. The largest errors, up to 2,5 cm, have been found for a lesion placed between source and electrodes and for a source internal to the lesion (not circumscribed tumours). We conclude that source localisation process is largely affected by a nearby lesion and thus electrical mapping of brain activity must be performed embedding brain lesions in the head model.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 50 条
  • [1] EEG source estimation accuracy in presence of simulated cortical lesions
    Caschera, S.
    Petti, M.
    Mattia, D.
    Astolfi, L.
    [J]. 2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 544 - 547
  • [2] Accuracy of EEG source reconstruction in the presence of brain lesions: modelling errors and surface electrodes' placement
    Vatta, F
    Bruno, P
    Inchingolo, P
    [J]. BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 38, 2002, 38 : 423 - 428
  • [3] Accuracy of EEG dipole source localization using implanted sources in the human brain
    Krings, T
    Chiappa, KH
    Cuffin, BN
    Cochius, JI
    Connolly, S
    Cosgrove, GR
    [J]. CLINICAL NEUROPHYSIOLOGY, 1999, 110 (01) : 106 - 114
  • [4] Accuracy of EEG source imaging of epileptic spikes in patients with large brain lesions
    Brodbeck, Verena
    Lascano, Agustina M.
    Spinelli, Laurent
    Seeck, Margitta
    Michel, Christoph M.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2009, 120 (04) : 679 - 685
  • [5] Influence of measurement noise and electrode mislocalisation on EEG dipole-source localisation
    Van Hoey, G
    Vanrumste, B
    D'Havé, M
    Van de Walle, R
    Lemahieu, I
    Boon, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (03) : 287 - 296
  • [6] Influence of measurement noise and electrode mislocalisation on EEG dipole-source localisation
    G. Van Hoey
    B. Vanrumste
    M. D'Havé
    R. Van de Walle
    I. Lemahieu
    P. Boon
    [J]. Medical and Biological Engineering and Computing, 2000, 38 : 287 - 296
  • [7] Accuracy of automated interictal source localisation based on high-density EEG
    Vorderwuelbecke, Bernd
    Baroumand, Amir Ghasemi
    Spinelli, Laurent
    Seeck, Margitta
    van Mierlo, Pieter
    Vulliemoz, Serge
    [J]. EPILEPSIA, 2021, 62 : 125 - 126
  • [8] EEG dipole source localisation of interictal spikes acquired during routine clinical video-EEG monitoring
    Meckes-Ferber, S
    Roten, A
    Kilpatrick, C
    O'Brien, T
    [J]. EPILEPSIA, 2004, 45 : 79 - 79
  • [9] Effects of dipole position, orientation and noise on the accuracy of EEG source localization
    Whittingstall, Kevin
    Stroink, Gerhard
    Gates, Larry
    Connolly, J. F.
    Finley, Allen
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2003, 2 (1)
  • [10] EEG dipole source localisation of interictal spikes acquired during routine clinical video-EEG monitoring
    Meckes-Ferber, S
    Roten, A
    Kilpatrick, C
    O'Brien, TJ
    [J]. CLINICAL NEUROPHYSIOLOGY, 2004, 115 (12) : 2738 - 2743