Real-time three-dimensional color-Doppler evaluation of the flow convergence surface for quantification of mitral regurgitation

被引:0
|
作者
Sitges, M
Shiota, T
Tsujino, H
Qin, JX
Bauer, F
Agler, DA
Cardon, LA
Panza, JA
机构
[1] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[2] NIH, Bethesda, MD 20892 USA
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
3053
引用
收藏
页码:629 / 629
页数:1
相关论文
共 50 条
  • [1] Real-time dynamic three-dimensional color flow Doppler assessment of mitral regurgitation
    Doddamani, S
    Keane, MG
    Frankel, DS
    Fishman, L
    Hungler, E
    Plappert, T
    Sutton, J
    Wiegers, SE
    CIRCULATION, 2004, 110 (17) : 571 - 571
  • [2] Real-time three-dimensional color Doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience
    Sitges, M
    Jones, M
    Shiota, T
    Qin, JX
    Tsujino, H
    Bauer, F
    Kim, YJ
    Agler, DA
    Cardon, LA
    Zetts, AD
    Panza, JA
    Thomas, JD
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (01) : 38 - 45
  • [3] Quantification of mitral regurgitant volume by real-time three-dimensional color Doppler echocardiography: Validation by the flow convergence method
    Lodato, JA
    Weinert, L
    Sugeng, L
    Baumann, R
    Lang, RM
    CIRCULATION, 2004, 110 (17) : 654 - 654
  • [4] Quantitative analysis of mitral eccentric regurgitation jet based on real-time three-dimensional color Doppler flow images
    Qi, L
    Ge, YN
    Fu, WT
    Li, R
    Wavelet Analysis and Active Media Technology Vols 1-3, 2005, : 779 - 782
  • [5] Quantification of Mitral Regurgitation by Real Time Three-Dimensional Color Doppler Flow Echocardiography Pre- and Post-Percutaneous Mitral Valve Repair
    Gruner, Christiane
    Herzog, Bernhard
    Bettex, Dominique
    Felix, Christian
    Datta, Saurabh
    Greutmann, Matthias
    Gaemperli, Oliver
    Mueggler, Simon A.
    Tanner, Felix C.
    Gruenenfelder, Juerg
    Corti, Roberto
    Biaggi, Patric
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2015, 32 (07): : 1140 - 1146
  • [6] THE CLINICAL VALUE OF COLOR DOPPLER FLOW CONVERGENCE IN THE QUANTIFICATION OF MITRAL REGURGITATION
    戴振林
    沈卫峰
    于金德
    胡厚达
    张大东
    Medical Bulletin of Shanghai Jiaotong University, 1995, (02) : 19 - 24
  • [7] In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation
    Little, Stephen H.
    Igo, Stephen R.
    Pirat, Bahar
    McCulloch, Marti
    Hartley, Craig J.
    Nose, Yukihiko
    Zoghbi, William A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (10): : 1440 - 1447
  • [8] Direct Quantification of Mitral Regurgitant Flow Volume by Real-Time Three-Dimensional Echocardiography Using Dealiasing of Color Doppler Flow at the Vena Contracta
    Plicht, Bjoern
    Kahlert, Philipp
    Goldwasser, Ranny
    Janosi, Rolf-Alexander
    Hunold, Peter
    Erbel, Raimund
    Buck, Thomas
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) : 1337 - 1346
  • [9] Real-time three-dimensional echocardiography in ischemic mitral regurgitation
    Jackson, BM
    Parish, LM
    Gorman, RC
    Gorman, JH
    CIRCULATION, 2004, 110 (17) : 673 - 673
  • [10] Real-time three-dimensional echocardiography in ischemic mitral regurgitation
    Jackson, BM
    Parish, LM
    Gorman, RC
    Gorman, JH
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (06) : S132 - S132