Reversible Ratiometric Electrochemiluminescence Biosensor Based on DNAzyme Regulated Resonance Energy Transfer for Myocardial miRNA Detection

被引:35
|
作者
Sun, Yudie [1 ]
Fang, La [1 ]
Han, Yunxiang [1 ]
Feng, Aobo [1 ]
Liu, Shengjun [1 ]
Zhang, Kui [1 ]
Xu, Jing-Juan [2 ]
机构
[1] Anhui Univ Technol, Sch Chem & Chem Engn, Maanshan 243032, Anhui, Peoples R China
[2] Nanjing Univ, State Key Lab Analyt Chem Life Sci, Sch Chem & Chem Engn, Nanjing 210023, Peoples R China
基金
中国国家自然科学基金;
关键词
QUANTUM DOTS; AMPLIFICATION; FLUORESCENCE; COMBINATION; NANOPARTICLES; MICRORNAS; PROBE;
D O I
10.1021/acs.analchem.2c00195
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Myocardial miRNAs in peripheral blood are closely related to the pathogenic process of myocardial infarction. Rapid identification and accurate quantification of myocardial miRNAs are of great significance to clinical interventions for treating cardiovascular lesions. Therefore, a ratiometric electrochemiluminescence (ECL) biosensor integrating DNAzyme with a resonance energy transfer (RET) system was designed to detect myocardial miRNA. The dual-signal system was composed of rA marked substrate strand functionalized CdTe quantum dots (QDs) as reductive-oxidative (R-O) emitters and Cy5-labeled strand-functionalized Ru(bpy)(3)(2+)-filled silica nanoparticles (RuSi NPs) as oxidative-reductive (O-R) emitters. In the presence of target miRNA, DNAzyme was activated to cut substrate strands on the CdTe QDs and release triggers for opening hairpin probes. Then, the Cy5 molecule-labeled hairpin DNA on the RuSi NPs was opened to introduce Cy5 molecules and RuSi NPs into the system. The R-O ECL was quenched by ECL-RET between CdTe QDs and Cy5 molecules and the O-R ECL was introduced by the RuSi NPs. In this way, based on the simultaneous changing of the ECL signal, the dual-potential dynamic signal ratiometric ECL sensing platform was developed. By measuring the ratio of O-R ECL signal to R-O ECL signal, the concentration of miRNA-499 was accurately quantified in the range of 10 fM to 10 nM, and the detection limit was as low as 2.44 NI (S/N = 3). This DNAzyme guided dual-potential ratiometric ECL method provides a sensitive and reliable method for myocardial miRNA detection, and it has great potential in clinical diagnosis and treatment.
引用
收藏
页码:7035 / 7040
页数:6
相关论文
共 50 条
  • [1] Electrochemiluminescence Resonance Energy Transfer System for Dual-Wavelength Ratiometric miRNA Detection
    Huo, Xiao-Lei
    Zhang, Nan
    Yang, Hui
    Xu, Jing-Juan
    Chen, Hong-Yuan
    ANALYTICAL CHEMISTRY, 2018, 90 (22) : 13723 - 13728
  • [2] Novel "signal-on" electrochemiluminescence biosensor for the detection of PSA based on resonance energy transfer
    Wu, Mei-Sheng
    Chen, Ruo-Nan
    Xiao, Yao
    Lv, Zi-Xin
    TALANTA, 2016, 161 : 271 - 277
  • [3] A reusable potassium ion biosensor based on electrochemiluminescence resonance energy transfer
    He, Li-Jing
    Wu, Mei-Sheng
    Xu, Jing-Juan
    Chen, Hong-Yuan
    CHEMICAL COMMUNICATIONS, 2013, 49 (15) : 1539 - 1541
  • [4] Ratiometric Detection of Zn2+ Using DNAzyme-Based Bioluminescence Resonance Energy Transfer Sensors
    Wu, Yuting
    Lewis, Whitney
    Wai, Jing Luen
    Xiong, Mengyi
    Zheng, Jiao
    Yang, Zhenglin
    Gordon, Chloe
    Lu, Ying
    New, Siu Yee
    Zhang, Xiao-Bing
    Lu, Yi
    CHEMISTRY-SWITZERLAND, 2023, 5 (03): : 1745 - 1759
  • [5] Sensitive dual-target electrochemiluminescence biosensor for simultaneous miRNA detection using magnetic carbon nanotubes and resonance energy transfer
    Liu, Chi-Hsien
    Malla, Pravanjan
    Wu, Wei-Chi
    Ganesan, Selvaganapathy
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 424
  • [6] An intra-stimuli resonance energy transfer-based electrochemiluminescence biosensor for DNA methylation detection
    Wang, Huan
    Peng, Minghui
    Feng, Qiumei
    Liu, Jing
    Zhang, Lang
    Wang, Po
    CHEMICAL ENGINEERING JOURNAL, 2024, 492
  • [7] Ratiometric Fluorescent Biosensor Based on Forster Resonance Energy Transfer between Carbon Dots and Acridine Orange for miRNA Analysis
    Sun, Zhiwei
    Tong, Yao
    Zhou, Xiaoyu
    Li, Juan
    Zhao, Li
    Li, Hui
    Wang, Chuanxin
    Du, Lutao
    Jiang, Yanyan
    ACS OMEGA, 2021, 6 (49): : 34150 - 34159
  • [8] A ratiometric electrochemiluminescence resonance energy transfer platform based on novel dye BODIPY derivatives for sensitive detection of lactoferrin
    Lu, Yao
    Ke, Hong
    Wang, Yang
    Zhang, Yao
    Li, Huan
    Huang, Chusen
    Jia, Nengqin
    BIOSENSORS & BIOELECTRONICS, 2020, 170 (170):
  • [9] DNAzyme Sensor Uses Chemiluminescence Resonance Energy Transfer for Rapid, Portable, and Ratiometric Detection of Metal Ions
    Zheng, Jiao
    Wai, Jing Luen
    Lake, Ryan J.
    New, Siu Yee
    He, Zhike
    Lu, Yi
    ANALYTICAL CHEMISTRY, 2021, 93 (31) : 10834 - 10840
  • [10] A DNAzyme-Based Dual-Stimuli Responsive Electrochemiluminescence Resonance Energy Transfer Platform for Ultrasensitive Anatoxin-a Detection
    Xia, Mengmeng
    Zhou, Fu
    Feng, Xiuyun
    Sun, Jiahui
    Wang, Li
    Li, Na
    Wang, Xiayan
    Wang, Guangfeng
    ANALYTICAL CHEMISTRY, 2021, 93 (32) : 11284 - 11290