A PRELIMINARY PROPOSAL FOR QUALITY CONTROL ASSESSMENT AND HARMONIZATION OF LEUKOCYTES MORPHOLOGY-STRUCTURAL PARAMETERS (CELL POPULATION DATA PARAMETERS)

被引:7
|
作者
Seghezzi, Michela [1 ]
Buoro, Sabrina [1 ]
Previtali, Giulia [1 ]
Moioli, Valentina [1 ]
Manenti, Barbara [1 ]
Simon-Lopez, Ramon [2 ]
Ottomano, Cosimo [3 ]
Lippi, Giuseppe [4 ]
机构
[1] Hosp Papa Giovanni XXIII, Clin Chem Lab, Piazza OMS 1, I-24127 Bergamo, Italy
[2] Sysmex Corp, Kobe, Hyogo, Japan
[3] Synlab, Castenedolo, Italy
[4] Univ Verona, Sect Clin Biochem, Verona, Italy
关键词
cell population data; quality control; within-run imprecision; reference range; stability; HEMATOLOGY ANALYZER; DATA CPD; SYSMEX;
D O I
10.2478/jomb-2018-0005
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: The cell population data (CPD) measured by Sysmex XN-9000 can be used for screening many hematological and non-hematological disorders. Since little information is available on harmonization of CPD among different instrumentation and clinical laboratories, this study aimed at assessing the current degree of CPD harmonization between separate Sysmex XN modules allocated to the same laboratory. Methods: A total number of 78291 data were used for verification of within-run imprecision, analyzers harmonization, reference ranges and assessment of blood sample stability of CPD parameters, including results of daily quality control testing and those generated in samples collected from blood donors and healthy volunteers. Results: Within-run imprecision of CPD parameters ranged between 0.4 and 14.1%. Good agreement was found among five different XN-modules, especially when values were adjusted after calculation of instrument-specific alignment factors. The bias of all parameters remained always lower than the reference change values in samples stored for up to 8 hours, regardless of storage temperature. Conclusions: The imprecision of CPD parameters was acceptable, except for those reflecting the dispersion of cellular clusters. Due to the lack of reference control materials, we showed that the use of data generated on a large number of normal routine samples (i.e., a Moving Average population) may be a reliable approach for testing analyzers harmonization. Nevertheless, availability of both calibration and quality control materials for these parameters is highly advisable in the future. We finally showed that whole blood samples may be stable for up to 2-4 hours for most CPD parameters.
引用
收藏
页码:486 / 498
页数:13
相关论文
共 5 条
  • [1] Quality Control of Structural Parameters (CELL POPULATION DATA) of Sysmex XN Series
    Simon-Lopez, Ramon
    Buoro, Sabrina
    Pacioni, Aurelio
    Seghezzi, Michela
    Manenti, Barbara
    [J]. BLOOD, 2016, 128 (22)
  • [2] Short- and medium-term biological variation estimates of leukocytes extended to differential count and morphology-structural parameters (cell population data) in blood samples obtained from healthy people
    Buoro, Sabrina
    Carobene, Anna
    Seghezzi, Michela
    Manenti, Barbara
    Pacioni, Aurelio
    Ceriotti, Ferruccio
    Ottomano, Cosimo
    Lippi, Giuseppe
    [J]. CLINICA CHIMICA ACTA, 2017, 473 : 147 - 156
  • [3] Fertility parameters in a bovin population : including data quality control
    Granados-Chapatte, A
    Baret, P
    [J]. 9TH MEETING ON RUMINANT RESEARCH, 2002, : 153 - 153
  • [4] PRE-TREATMENT STAGING FDG PET/CT ASSESSMENT OF MANTLE CELL LYMPHOMA: A COMPARISON OF VISUAL ASSESSMENT VERSUS ASSESSMENT BY QUANTITATIVE FDG PARAMETERS. METHODOLOGY AND PRELIMINARY DATA
    Lee, S.
    Styles, C.
    Ma, D.
    Rose, H.
    [J]. INTERNAL MEDICINE JOURNAL, 2017, 47 : 6 - 6
  • [5] THE NEED FOR IMMEDIATE MONITORING OF TREATMENT PARAMETERS AND UNIFORM ASSESSMENT OF PATIENT DATA IN CLINICAL-TRIALS - A QUALITY-CONTROL STUDY OF THE EORTC RADIOTHERAPY AND LUNG-CANCER COOPERATIVE GROUPS
    SCHAAKEKONING, C
    KIRKPATRICK, A
    KROGER, R
    VANZANDWIJK, N
    BARTELINK, H
    [J]. EUROPEAN JOURNAL OF CANCER, 1991, 27 (05) : 615 - 619