Analysis of fenthion in postmortem samples by HPLC with diode-array detection and GC-MS using solid-phase extraction

被引:18
|
作者
Meyer, E
Borrey, D
Lambert, W
Van Peteghem, C
Piette, M
De Leenheer, A
机构
[1] State Univ Ghent, Toxicol Lab, B-9000 Ghent, Belgium
[2] State Univ Ghent, Lab Gerechtelijke Geneeskunde, B-9000 Ghent, Belgium
关键词
D O I
10.1093/jat/22.3.248
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fenthion (O,O-dimethyl-O-[3-methyl-4-(methylthio)-phenyl-thiophos- phate) is an organophosphate insecticide. A specific method for quantitate fenthion, in postmortem matrices with solid-phase extraction combined with high-performance liquid chromatography-diode-array detection (HPLC-DAD) and gas chromatography-mass spectrometry (GC-MS) is presented. Fenitrothion (O,O- dimethyl-O-[3-methyl-4- nitrophenyl]-thiophosphate) is selected as the internal standard. For sample cleanup, a simple but selective solid-phase exraction is chosen after comparison with traditional liquid-liquid extraction procedures. Homogenized and appropriately diluted aqueous samples are applied, and the analytes are desorbed with 5 mL of dichloromethane. Aliquots of the extract are used for HPLC-DAD and GC-MS analysis. Liquid and GC conditions are as follows: gradient elution with a mixture of methanol and water (10:90 to 90:10, v/v) containing 0.0125M NaOH on an Aluspher RP-Select B column monitoring at 250 nm, and temperature programming from 60 to 300°C on a dimethylpolysi1oxane column in the SCAN mode, respectively. This method is applied to a suicidal case involving unsuspected acute intoxication with fenthion (concentration in blood, 3.8 μg/mL).
引用
收藏
页码:248 / 252
页数:5
相关论文
共 50 条
  • [1] Analysis of Zopiclone (Imovane(R)) in postmortem specimens by GC-MS and HPLC with diode-array detection
    VanBocxlaer, J
    Meyer, E
    Clauwaert, K
    Lambert, W
    Piette, M
    DeLeenheer, A
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (01) : 52 - 54
  • [2] Analysis of etorphine in postmortem samples by HPLC with UV diode-array detection
    Elliott, SP
    Hale, KA
    [J]. FORENSIC SCIENCE INTERNATIONAL, 1999, 101 (01) : 9 - 16
  • [3] Multiresidue analysis of cotton defoliant, herbicide, and insecticide residues in water by solid-phase extraction and GC-NPD, GC-MS, and HPLC-diode array detection
    Potter, TL
    Marti, L
    Belflower, S
    Truman, CC
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2000, 48 (09) : 4103 - 4108
  • [4] ANALYTICAL VALIDATION METHOD FOR THE DETERMINATION OF SULFONYLUREA HERBICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND HPLC WITH DIODE-ARRAY DETECTION
    Grahovac, N.
    Suturovic, Z.
    Kondic-Spika, A.
    Sekulic, P.
    Lazic, S.
    Sunjka, D.
    Jaksic, S.
    [J]. PROCEEDINGS OF THE 13TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013,
  • [5] SIMULTANEOUS ANALYSIS OF 50 PESTICIDES IN WATER SAMPLES BY SOLID-PHASE EXTRACTION AND GC-MS
    BENFENATI, E
    TREMOLADA, P
    CHIAPPETTA, L
    FRASSANITO, R
    BASSI, G
    DITORO, N
    FANELLI, R
    STELLA, G
    [J]. CHEMOSPHERE, 1990, 21 (12) : 1411 - 1421
  • [6] TRACE ENRICHMENT AND HPLC ANALYSIS OF POLYCYCLIC AROMATIC-HYDROCARBONS IN ENVIRONMENTAL-SAMPLES, USING SOLID-PHASE EXTRACTION IN CONNECTION WITH UV/VIS DIODE-ARRAY AND FLUORESCENCE DETECTION
    KICINSKI, HG
    ADAMEK, S
    KETTRUP, A
    [J]. CHROMATOGRAPHIA, 1989, 28 (3-4) : 203 - 208
  • [7] FLUOXETINE AND NORFLUOXETINE ANALYSIS USING SOLID-PHASE EXTRACTION AND GC/MS DETECTION
    FOX, DJ
    LONG, G
    TELEPCHAK, M
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 203 : 186 - ENVR
  • [8] Application of Solid-Phase Extraction and Planar Chromatography with Diode-Array Detection to the Qualitative and Quantitative Analysis of Dyes in Beverages
    Tomasz Tuzimski
    Arkadiusz Woźniak
    [J]. JPC – Journal of Planar Chromatography – Modern TLC, 2008, 21 : 89 - 96
  • [9] Application of solid-phase extraction and planar chromatography with diode-array detection to the qualitative and quantitative analysis of dyes in beverages
    Tuzimski, Tomasz
    Wozniak, Arkadiusz
    [J]. JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2008, 21 (02) : 89 - 96
  • [10] Development of an interface for directly coupled solid-phase extraction and GC-MS analysis
    Ollers, S
    vanLieshout, M
    Janssen, HG
    Cramers, CA
    [J]. LC GC-MAGAZINE OF SEPARATION SCIENCE, 1997, 15 (09): : 846 - &