Gyroscopes; Accelerometers; Feature extraction; Electrocardiography; Sensors; Estimation; Biomedical measurement; Accelerometer; cardiovascular monitoring; ensemble regression; gyroscope; heart failure; seismocardiogram; sensor fusion; wearable sensors; SYSTOLIC-TIME INTERVALS; HEART-FAILURE; BALLISTOCARDIOGRAPHY; CONTRACTILITY; PARAMETERS;
D O I
10.1109/JBHI.2019.2895775
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Objective: Systolic time intervals, such as the pre-ejection period (PEP), are important parameters for assessing cardiac contractility that can be measured non-invasively using seismocardiography (SCG). Recent studies have shown that specific points on accelerometer- and gyroscope-based SCG signals can be used for PEP estimation. However, the complex morphology and inter-subject variation of the SCG signal can make this assumption very challenging and increase the root mean squared error (RMSE) when these techniques are used to develop a global model. Methods: In this study, we compared gyroscope- and accelerometer-based SCG signals, individually and in combination, for estimating PEP to show the efficacy of these sensors in capturing valuable information regarding cardiovascular health. We extracted general time-domain features from all the axes of these sensors and developed global models using various regression techniques. Results: In single-axis comparison of gyroscope and accelerometer, angular velocity signal around head to foot axis from the gyroscope provided the lowest RMSE of 12.63 0.49 ms across all subjects. The best estimate of PEP, with a RMSE of 11.46 0.32 ms across all subjects, was achieved by combining features from the gyroscope and accelerometer. Our global model showed 30 lower RMSE when compared to algorithms used in recent literature. Conclusion: Gyroscopes can provide better PEP estimation compared to accelerometers located on the mid-sternum. Global PEP estimation models can be improved by combining general time domain features from both sensors. Significance: This work can be used to develop a low-cost wearable heart-monitoring device and to generate a universal estimation model for systolic time intervals using a single- or multiple-sensor fusion.
引用
收藏
页码:2365 / 2374
页数:10
相关论文
共 20 条
  • [1] Universal Pre-Ejection Period Estimation Using Seismocardiography: Quantifying the Effects of Sensor Placement and Regression Algorithms
    Ashouri, Hazar
    Hersek, Sinan
    Inan, Omer T.
    IEEE SENSORS JOURNAL, 2018, 18 (04) : 1665 - 1674
  • [2] Multi-Channel Audio-based Estimation of the Pre-Ejection Period
    Paiva, R. P.
    Sapata, T.
    Henriques, J.
    Quintal, I.
    Baptista, R.
    Goncalves, L.
    Carvalho, P.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5932 - 5935
  • [3] Detection of Aortic Valve Opening and Estimation of Pre-Ejection Period in Forcecardiography Recordings
    Centracchio, Jessica
    Andreozzi, Emilio
    Esposito, Daniele
    Gargiulo, Gaetano Dario
    Bifulco, Paolo
    BIOENGINEERING-BASEL, 2022, 9 (03):
  • [4] Assessment of Pre-ejection Period in Ambulatory Subjects using Seismocardiogram in a Wearable Blood Pressure Monitor
    Zhang, Guanqun
    Cottrell, Amber C.
    Henry, Isaac C.
    McCombie, Devin B.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3386 - 3389
  • [5] The Effects of Pre-Ejection Period on the Blood Pressure Estimation Using Pulse Transit Time
    Wong, M. Y. M.
    Zhang, Y. T.
    2008 5TH INTERNATIONAL SUMMER SCHOOL AND SYMPOSIUM ON MEDICAL DEVICES AND BIOSENSORS, 2008, : 301 - 302
  • [6] Automatic analysis of pre-ejection period during sleep using impedance cardiogram
    Forouzanfar, Mohamad
    Baker, Fiona C.
    Colrain, Ian M.
    Goldstone, Aimee
    de Zambotti, Massimiliano
    PSYCHOPHYSIOLOGY, 2019, 56 (07)
  • [7] Automatic Detection of Seismocardiogram Sensor Misplacement for Robust Pre-Ejection Period Estimation in Unsupervised Settings
    Ashouri, Hazar
    Inan, Omer T.
    IEEE SENSORS JOURNAL, 2017, 17 (12) : 3805 - 3813
  • [8] Cuffless estimation of systolic blood pressure for short effort bicycle tests: The prominent role of the pre-ejection period
    Muehlsteff, J.
    Aubert, X. L.
    Schuett, M.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3460 - +
  • [9] Improved Pre-Ejection Period Estimation From Ballistocardiogram and Electrocardiogram Signals by Fusing Multiple Timing Interval Features
    Bicen, A. Ozan
    Gurel, Nil Z.
    Dorier, Alexis
    Inan, Omer T.
    IEEE SENSORS JOURNAL, 2017, 17 (13) : 4172 - 4180
  • [10] The effects of pre-ejection period on post-exercise systolic blood pressure estimation using the pulse arrival time technique
    Mico Yee Man Wong
    Emma Pickwell-MacPherson
    Yuan Ting Zhang
    Jack C. Y. Cheng