Optimization of a circular piezoelectric bimorph for a micropump driver

被引:101
|
作者
Morris, CJ [1 ]
Forster, FK [1 ]
机构
[1] Univ Washington, Dept Mech Engn, Seattle, WA 98115 USA
关键词
D O I
10.1088/0960-1317/10/3/323
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Piezoelectric bimorph actuation has been successfully used in numerous types of microdevices, most notably micropumps. However, even for the simple case of circular geometry, analytical treatments are severely limited. This study utilized the finite-element method to optimize the deflection of a circular bimorph consisting of a single piezoelectric actuator, bonding material and elastic plate of finite dimensions. Optimum actuator dimensions were determined for given plate dimensions, actuator-to-plate stiffness ratio and bonding layer thickness. Dimensional analysis was used to present the results for fixed- and pinned-edge conditions in a generalized form for use as a design tool. For an optimally-thick actuator, the optimum actuator-to-plate radius ratio ranged from 0.81 to 1.0, and was independent of the Young's modulus ratio. For thin plates, a bonding layer minimally affected the optimum dimensions. The optimized actuator dimensions based on a model of an actual device were within 13% of the fixed-edge condition.
引用
收藏
页码:459 / 465
页数:7
相关论文
共 50 条
  • [1] A soft-polymer piezoelectric bimorph cantilever-actuated peristaltic micropump
    Graf, Neil J.
    Bowser, Michael T.
    [J]. LAB ON A CHIP, 2008, 8 (10) : 1664 - 1670
  • [2] Numerical Simulation of Bimorph Piezoelectric Beam with Circular Holes
    Singh R.R.
    Kumar D.
    Paswan M.
    [J]. Journal of The Institution of Engineers (India): Series D, 2023, 104 (01) : 309 - 318
  • [3] Research on Circular Bimorph Piezoelectric Boneconduction Hearing Device
    Sun, Jingyang
    Wu, Boda
    Cheng, Guangming
    Wen, Jianming
    Zeng, Ping
    [J]. 2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 3359 - 3363
  • [4] Simulation and optimization of a piezoelectric micropump for medical applications
    Qifeng Cui
    Chengliang Liu
    Xuan F. Zha
    [J]. The International Journal of Advanced Manufacturing Technology, 2008, 36 : 516 - 524
  • [5] Simulation and optimization of a piezoelectric micropump for medical applications
    Cui, Qifeng
    Liu, Chengliang
    Zha, Xuan F.
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2008, 36 (5-6): : 516 - 524
  • [6] A piezo driver for piezoelectric bimorph actuators in micro-positioning application
    Chen, Yuansheng
    Zhao, Pengcheng
    Wang, Hao
    Qiu, Jinhao
    Yang, Guowen
    [J]. INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2020, 64 (1-4) : 615 - 620
  • [7] Modelling and analysis of circular bimorph piezoelectric actuator for deformable mirror
    Hairen WANG
    Ming HU
    Zhenqin LI
    [J]. Applied Mathematics and Mechanics(English Edition), 2016, 37 (05) : 639 - 646
  • [8] Modeling and analysis of the thermal effects of a circular bimorph piezoelectric actuator
    Wang, Hairen
    Yang, Shengfeng
    [J]. APPLIED OPTICS, 2016, 55 (04) : 873 - 878
  • [9] Modelling and analysis of circular bimorph piezoelectric actuator for deformable mirror
    Wang, Hairen
    Hu, Ming
    Li, Zhenqin
    [J]. APPLIED MATHEMATICS AND MECHANICS-ENGLISH EDITION, 2016, 37 (05) : 639 - 646
  • [10] Modelling and analysis of circular bimorph piezoelectric actuator for deformable mirror
    Hairen Wang
    Ming Hu
    Zhenqin Li
    [J]. Applied Mathematics and Mechanics, 2016, 37 : 639 - 646