Accelerator-based epithermal neutron sources for boron neutron capture therapy of brain tumors

被引:0
|
作者
Blue, TE
Yanch, JC
机构
[1] Ohio State Univ, Dept Mech Engn, Nucl Engn Program, Columbus, OH 43210 USA
[2] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[3] MIT, Whitaker Coll Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
accelerator; neutron; sources; BNCT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This paper reviews the development of low- energy light ion accelerator- based neutron sources ( ABNSs) for the treatment of brain tumors through an intact scalp and skull using boron neutron capture therapy ( BNCT). A major advantage of an ABNS for BNCT over reactor- based neutron sources is the potential for siting within a hospital. Consequently, light- ion accelerators that are injectors to larger machines in high- energy physics facilities are not considered. An ABNS for BNCT is composed of: ( 1) the accelerator hardware for producing a high current charged particle beam, ( 2) an appropriate neutron- producing target and target heat removal system ( HRS), and ( 3) a moderator/ reflector assembly to render the flux energy spectrum of neutrons produced in the target suitable for patient irradiation. As a consequence of the efforts of researchers throughout the world, progress has been made on the design, manufacture, and testing of these three major components. Although an ABNS facility has not yet been built that has optimally assembled these three components, the feasibility of clinically useful ABNSs has been clearly established. Both electrostatic and radio frequency linear accelerators of reasonable cost (similar to $ 1.5 M) appear to be capable of producing charged particle beams, with combinations of accelerated particle energy ( a few MeV) and beam currents (similar to 10 mA) that are suitable for a hospital- based ABNS for BNCT. The specific accelerator performance requirements depend upon the charged particle reaction by which neutrons are produced in the target and the clinical requirements for neutron field quality and intensity. The accelerator performance requirements are more demanding for beryllium than for lithium as a target. However, beryllium targets are more easily cooled. The accelerator performance requirements are also more demanding for greater neutron field quality and intensity. Target HRSs that are based on submerged- jet impingement and the use of microchannels have emerged as viable target cooling options. Neutron fields for reactor- based neutron sources provide an obvious basis of comparison for ABNS field quality. This paper compares Monte Carlo calculations of neutron field quality for an ABNS and an idealized standard reactor neutron field ( ISRNF). The comparison shows that with lithium as a target, an ABNS can create a neutron field with a field quality that is significantly better ( by a factor of similar to 1.2, as judged by the relative biological effectiveness ( RBE)- dose that can be delivered to a tumor at a depth of 6 cm) than that for the ISRNF. Also, for a beam current of 10 mA, the treatment time is calculated to be reasonable (similar to 30 min) for the boron concentrations that have been assumed.
引用
收藏
页码:19 / 31
页数:13
相关论文
共 50 条
  • [1] Accelerator-based epithermal neutron sources for boron neutron capture therapy of brain tumors
    Thomas E. Blue
    Jacquelyn C. Yanch
    Journal of Neuro-Oncology, 2003, 62 (1-2) : 19 - 31
  • [2] Accelerator-based Epithermal Neutron Sources for Boron Neutron Capture Therapy of Brain Tumors
    Thomas E. Blue
    Jacquelyn C. Yanch
    Journal of Neuro-Oncology, 2003, 62 (1) : 19 - 31
  • [3] Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    Taskaev, S. Yu.
    PHYSICS OF PARTICLES AND NUCLEI, 2019, 50 (05) : 569 - 575
  • [4] Designing accelerator-based epithermal neutron beams for boron neutron capture therapy
    Bleuel, DL
    Donahue, RJ
    Ludewigt, BA
    Vujic, J
    MEDICAL PHYSICS, 1998, 25 (09) : 1725 - 1734
  • [5] Development of an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    S. Yu. Taskaev
    Physics of Particles and Nuclei, 2019, 50 : 569 - 575
  • [6] Design for an accelerator-based orthogonal epithermal neutron beam for boron neutron capture therapy
    Allen, DA
    Beynon, TD
    Green, S
    MEDICAL PHYSICS, 1999, 26 (01) : 71 - 76
  • [7] Opportunities for Using an Accelerator-Based Epithermal Neutron Source for Boron Neutron Capture Therapy
    Taskaev S.Y.
    Kanygin V.V.
    Byvaltsev V.A.
    Zaboronok A.A.
    Volkova O.Y.
    Mechetina L.V.
    Taranin A.V.
    Kichigin A.I.
    Iarullina A.I.
    Eliseenko I.A.
    Nakai K.
    Sato E.
    Yamamoto T.
    Ishikawa E.
    Matsumura A.
    Biomedical Engineering, 2018, 52 (02) : 73 - 76
  • [8] An accelerator-based epithermal photoneutron source for boron neutron capture therapy
    Mitchell, HE
    MEDICAL PHYSICS, 1997, 24 (12) : 2057 - 2057
  • [9] A DESIGN STUDY OF AN ACCELERATOR-BASED EPITHERMAL NEUTRON SOURCE FOR BORON NEUTRON-CAPTURE THERAPY
    WANG, CKC
    BLUE, TE
    GAHBAUER, RA
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (2-3): : 75 - 78
  • [10] Optimization of an accelerator-based epithermal neutron source for neutron capture therapy
    Kononov, OE
    Kononov, VN
    Bokhovko, MV
    Korobeynikov, VV
    Soloviev, A
    Sysoev, AS
    Gulidov, IA
    Chub, WT
    Nigg, DW
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1009 - 1013