An On-Line Monitoring System for Nitrate in Seawater Based on UV Spectrum

被引:7
|
作者
Li Dan [1 ]
Feng Wei-wei [2 ]
Chen Ling-xin [2 ]
Zhang Jun [1 ]
机构
[1] Yantai Univ, Inst Optoelect Informat Sci & Technol, Yantai 264005, Peoples R China
[2] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Coastal Environm Engn Technol Res Ctr Shandong Pr, Yantai 264003, Peoples R China
关键词
Nitrate; Ultraviolet spectroscopy absorption technology; Partial least squares method; On-line Monitoring; SITU ULTRAVIOLET SPECTROPHOTOMETER;
D O I
10.3964/j.issn.1000-0593(2016)02-0442-03
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Nitrate is one of the evaluation indicators of water quality, which is particularly important for water quality monitoring. A real-time on-line monitoring system of nitrate in water is introduced in this paper. And the ultraviolet absorption technology (190 similar to 370 nm) with partial least squares method is used to detect nitrate concentration. The automated online system based on ultraviolet absorption spectrum is capable of analyzing samples without any sample preservation and without contamination problems. This system is fast, reliable, and sensitive enough for continuous use on monitoring stations and nitrate concentration can also be determined directly via its ultraviolet absorption spectrum. This system uses flow sample cell with 1cm optical path length, and a reference light is used to eliminate system error. The correlation coefficient for a linear function of the nitrate concentrations is 0. 999 98. So the results of the system model test are in good correlation with the laboratory ones. Data collected has been analyzed statistically to determine how system model behave throughout the test, with special attention being paid to error analysis. As the average relative error is 0. 65%, this system has greater stability and higher accuracy. The results of nitrate measurements by the field seawater tests in Yantai coast are obtained, which nitrate concentrations are about 0. 2 mg . L-1 in seawater, and the recoveries of samples for standard recovery tests are in 95%similar to 110%, it shows that this system is accurate, reliability and practicability and could be developed for detected nitrate concentration in natural water.
引用
收藏
页码:442 / 444
页数:3
相关论文
共 11 条
  • [1] Direct nitrate sensing in water using an array of copper-microelectrodes from flat flexible cables
    da Silva, Iranaldo S.
    de Araujo, William R.
    Paixao, Thiago R. L. C.
    Angnes, Lucio
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 94 - 98
  • [2] Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters
    Gentle, Brady S.
    Ellis, Peter S.
    Grace, Michael R.
    McKelvie, Ian D.
    [J]. ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) : 116 - 122
  • [3] Long-Term Nitrate Measurements in the Ocean Using the in situ Ultraviolet Spectrophotometer: Sensor Integration into the APEX Profiling Float
    Johnson, Kenneth S.
    Coletti, Luke J.
    Jannasch, Hans W.
    Sakamoto, Carole M.
    Swift, Dana D.
    Riser, Stephen C.
    [J]. JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2013, 30 (08) : 1854 - 1866
  • [4] LI Cai, 2013, SPECTROSC SPECT ANAL, V33, P1774
  • [5] Ren C.Z., 2006, IND SAFETY ENV PROTE, V32, P9, DOI DOI 10.3969/j.issn.1001-425X.2006.02.004
  • [6] Improved algorithm for the computation of nitrate concentrations in seawater using an in situ ultraviolet spectrophotometer
    Sakamoto, Carole M.
    Johnson, Kenneth S.
    Coletti, Luke J.
    [J]. LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2009, 7 : 132 - 143
  • [7] SHI Q, 2001, MAR SCI B, V20, P32
  • [8] Partial Least Squares local calibration of a UV-visible spectrometer used for in situ measurements of COD and TSS concentrations in urban drainage systems
    Torres, A.
    Bertrand-Krajewski, J. -L.
    [J]. WATER SCIENCE AND TECHNOLOGY, 2008, 57 (04) : 581 - 588
  • [9] Weingartner A., 2003, INT ENV TECH, V13, P146
  • [10] [郑瑞芝 ZHENG Ruizhi], 2011, [海洋科学进展, Advances in Marine Science], V29, P229