Outcome of Extra-Articular Fractures of Distal Femur: Less Invasive Stabilization on System (LISS) Plating versus Closed Retrograde Intramedullary Interlocking Nail

被引:4
|
作者
Mahar, Sijad Ahmed [1 ]
Aziz, Shaheryar [2 ]
Ahmed, Saeed [3 ]
Kumar, Jugdesh [4 ]
Ali, Sikandar [5 ]
机构
[1] Ghulam Muhammad Mahar Med Coll Sukkur, Orthopaed Surg, Sukkur, Pakistan
[2] M Islam Teaching Hosp Gujranwala, Orthopaed, Gujranwala, Punjab, Pakistan
[3] Victoria Hosp, Dept Orthopaed Surg, Bahawalpur, Pakistan
[4] Shaheed Mohtarma Benazir Bhutto Med Univ, Chandka Med Coll, Orthopaed, Larkana, Pakistan
[5] Indus Med Coll Hosp, Orthopaed & Trauma Surg, Tando Muhammad Khan, Pakistan
来源
关键词
Fracture of distal femur; LISS plating; Interlocking nail; FEMORAL FRACTURES; FIXATION;
D O I
10.53350/pjmhs211551144
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the functional outcome of extra-articular fracture of distal femur, LISS plating versus retrograde intramedullary interlocking nailing. Study Design: Prospective/Randomized control trial Place and Duration of Study: Department of Orthopaedic Surgery, Ghulam Muhammad Mahar Medical College Sukkur from 1st July 2019 to 31st December 2020. Methodology: One hundred patients of both genders with ages 20 to 60 years presented with fractures of distal femur were included in this study. Patients were equally divided into two groups I and II. Group I contained 50 patients and received LISS plating and Group II contained 50 patients and received closed retrograde intramedullary interlocking nail, Pre and post-operative assessment was done. Post-operative complications were noted at 12th day. Functional outcomes were examined after 6 months by the NEERs criteria. Results: Sixty five (65%) patients were males (35 in group I and 30 in group II) and 35 (35%) patients were females (15 in group I and 20 in group II). Road traffic accident was the most common mode of injury in 62 (62%) patients. Most of the fractures were on right side 66 (66%). According to the NEER criteria, 80% patients shows excellent, 20% patients shows satisfactory with no poor results in Group I and in Group II 30% patients shows excellent, 66% patients shows satisfactory results and 4% shows unsatisfactory results. Conclusion: The LISS plating and closed retrograde intramedullary interlocking nail was safe and effective methods for extra-articular fractures of distal femur but there were less complications found in LISS plating.
引用
收藏
页码:1144 / 1147
页数:4
相关论文
共 50 条
  • [1] Comparison of retrograde intramedullary nailing and bridge plating in the treatment of extra-articular fractures of the distal femur
    Demirtas, Abdullah
    Azboy, Ibrahim
    Ozkul, Emin
    Gem, Mehmet
    Alemdar, Celil
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (05) : 521 - 526
  • [2] Retrograde tibial intramedullary nail versus minimally invasive locking plate for extra-articular distal tibial fractures: a comparative and retrospective study
    Liu, Hui
    Xu, Weizhen
    Xiong, Yuanfei
    Zhang, Jinhui
    Xu, Zunying
    Wu, Jin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [3] Comparison of retrograde and antegrade tibial intramedullary nail in the treatment of extra-articular distal tibial fractures
    Hui Liu
    Weibin Lin
    Weizhen Xu
    Yuanfei Xiong
    Jinhui Zhang
    Jin Wu
    International Orthopaedics, 2025, 49 (1) : 219 - 227
  • [4] Biomechanical evaluation of the Less Invasive Stabilization System, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures
    Zlowodzki, M
    Williamson, S
    Cole, PA
    Zardiackas, LD
    Kregor, PJ
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2004, 18 (08) : 494 - 502
  • [5] Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate
    Safi, A.
    Hart, R.
    Teknedzjan, B.
    Kozak, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 774 - 779
  • [6] The development of the distal femur Less Invasive Stabilization System (LISS)
    Frigg, R
    Appenzeller, A
    Christensen, R
    Frenk, A
    Gilbert, S
    Schavan, R
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 : 24 - 31
  • [7] Failure of Less-Invasive Stabilization System (LISS) plating for periprosthetic distal femur fractures Three case reports
    Tian Zhen-Jiang
    Liu Yan-Jie
    Chen Bo-Jian
    Wang Jun
    Niu Cai-Li
    Feng En-Hui
    Mai Xiu-Jun
    Huang Yong-Ming
    MEDICINE, 2020, 99 (08)
  • [8] Intramedullary nailing versus percutaneous locked plating of distal extra-articular tibial fractures: A retrospective study
    Seyhan M.
    Unay K.
    Sener N.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (5) : 595 - 601
  • [9] Intramedullary nailing versus minimally invasive plating in the treatment of distal tibial extra-articular fractures: Comparison of cost analysis in Turkey
    Koksal, Alper
    Cimen, Osman
    Oner, Ali
    Aycan, Osman Emre
    Abul, Kadir
    Akgun, Hakan
    Kaya, Ozan
    Yapici, Furkan
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (05): : 558 - 564
  • [10] Retrograde Nailing versus Locked Plating of Extra-Articular Distal Femoral Fractures: Comparison of 36 Cases
    Gao, Kanda
    Gao, Wei
    Huang, Jianhua
    Li, Haoqing
    Li, Fan
    Tao, Jie
    Wang, Qiugen
    MEDICAL PRINCIPLES AND PRACTICE, 2013, 22 (02) : 161 - 166