Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

被引:2
|
作者
Honda, Tsuyoshi [1 ]
Fujimoto, Kazuteru [2 ]
Miyao, Yuji [2 ]
机构
[1] Natl Hosp Org, Kumamoto Saisyunsou Hosp, Dept Cardiol, Kumamoto 8611196, Japan
[2] Natl Hosp Org, Kumamoto Med Ctr, Ctr Cardiovasc, Dept Cardiol, Kumamoto, Japan
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2014年 / 10卷 / 04期
关键词
virtual 3-Fr percutaneous coronary intervention;
D O I
10.5114/pwki.2014.46763
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control. Aim: To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes. Material and methods: We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works (TM), Medikit, Japan) or standard guiding catheters (Heartrail (TM), Terumo, Japan). Results: Thirty-five patients were identified (63% men; mean age 70 +/- 13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One Of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 "slender mother and child" PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study. Conclusions: These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [1] Percutaneous Coronary Intervention Using a Virtual 3-Fr Guiding Catheter
    Mizuno, Shingo
    Takeshita, Satoshi
    Taketani, Yoshio
    Saito, Shigeru
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (07) : 983 - 988
  • [2] Feasibility and Safety of a Virtual 3-Fr Sheathless-Guiding System for Percutaneous Coronary Intervention
    Tonomura, Daisuke
    Shimada, Yoshihisa
    Yano, Kentaro
    Ito, Kazato
    Takehara, Kosuke
    Kino, Naoto
    Furubayashi, Keiichi
    Kurotobi, Toshiya
    Tsuchida, Takao
    Fukumoto, Hitoshi
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (03) : 426 - 435
  • [3] Percutaneous transluminal coronary angioplasty using 6 Fr guiding catheters: A matched study with 8 Fr guiding catheters
    Bedossa, M
    LeBreton, H
    Zaki, A
    Leclercq, C
    Foulgoc, JL
    Bories, J
    Pony, JC
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1996, 9 (05) : 373 - 379
  • [4] Using sheathless standard guiding catheters for transradial percutaneous coronary intervention to treat bifurcation lesions
    Li, Qiyong
    He, Yong
    Jiang, Rongjian
    Huang, Dejia
    [J]. EXPERIMENTAL & CLINICAL CARDIOLOGY, 2013, 18 (02) : 73 - 76
  • [5] Comparison of novel 6.5 Fr sheathless guiding catheters versus 5 Fr guiding catheters for transradial coronary intervention
    Chiam, Paul T. L.
    Liu, Bing
    Wong, Aaron S. L.
    Wong, Philip E. H.
    Lim, Soo-Teik
    Koh, Tian-Hai
    Lim, Victor Y. T.
    [J]. EUROINTERVENTION, 2011, 7 (08) : 930 - 935
  • [6] Double Guiding Catheters for Complex Percutaneous Coronary Intervention
    Chou, Shing-Hsien
    Lin, Chia-Pin
    Lin, Yen-Chen
    Kuo, Chi-Tai
    Lin, Ming-Shyan
    Chang, Chi-Jen
    [J]. TEXAS HEART INSTITUTE JOURNAL, 2012, 39 (01) : 112 - 115
  • [7] Transradial percutaneous coronary intervention for chronic total occlusion of coronary artery disease using sheathless standard guiding catheters
    Chen, Huang-Chung
    Lee, Wei-Chieh
    Hsueh, Shu-Kai
    Cheng, Cheng-I
    Chen, Chien-Jen
    Yang, Cheng-Hsu
    Fang, Chih-Yuan
    Hang, Chi-Ling
    Yip, Hon-Kan
    Wu, Chiung-Jen
    Fang, Hsiu-Yu
    [J]. IJC HEART & VASCULATURE, 2015, 6 : 35 - 41
  • [8] Five French (5 Fr) guiding catheters for percutaneous coronary angioplasty and stent placement: An initial feasibility study
    Schussler, JM
    Smith, R
    Schreibfeder, M
    Hill, D
    Anwar, A
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 51 (03) : 352 - 357
  • [9] Virtual 3 Fr PCI system for complex percutaneous coronary intervention
    Matsukage, Takashi
    Yoshimachi, Fuminobu
    Masutani, Motomaru
    Saito, Shigeru
    Nakazawa, Gaku
    Masuda, Naoki
    Ogata, Nobuhiko
    Morino, Yoshihiro
    Ikari, Yuji
    [J]. EUROINTERVENTION, 2009, 5 (04) : 515 - 517
  • [10] Percutaneous Coronary Intervention with a Virtual 2-Fr System
    Tanaka, Akihito
    Saito, Shigeru
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (05) : 684 - 686