Cryoglobulin evaluation: best practice?

被引:74
|
作者
Sargur, Ravishankar [1 ]
White, Peter
Egner, William [2 ]
机构
[1] No Gen Hosp, Dept Immunol, Clin Immunol Unit, Sheffield S5 8YD, S Yorkshire, England
[2] No Gen Hosp, Prot Reference Unit, Dept Immunol, Sheffield S5 7AU, S Yorkshire, England
关键词
HEPATITIS-C VIRUS; MIXED CRYOGLOBULINEMIA; SJOGRENS-SYNDROME; B-LYMPHOCYTES; RITUXIMAB; GLOMERULONEPHRITIS; PREVALENCE; NEUROPATHY; MECHANISM; INFECTION;
D O I
10.1258/acb.2009.009180
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Cryoglobulins are serum immunoglobulins that precipitate at temperatures below 37 degrees C and re-dissolve on warming. Cryoglobulinaemia leads to variable symptoms including characteristic purpura, ischaemia of extremities, renal failure, peripheral neuropathy, abdominal pain secondary to intestinal ischaemia and arthralgias. Cryoglobulin testing is underutilized in clinical practice. It has been neglected in clinical laboratories and by clinicians due to several factors, such as the length of time it takes for serum cryoglobulin analysis to be performed in the laboratory, the perceived difficulty in getting optimal sampling conditions and a failure to appreciate that even apparently low levels of cryoglobulin can be associated with severe symptoms in some patients. The most important variable confounding standardization of cryoglobulin testing is improper sample handling. A recent report critically appraising the current practice of cryoglobulin evaluation in 137 laboratories in Europe by United Kingdom National External Quality Assurance Scheme (UKNEQAS) illustrated the wide variability in practice. Although many clinical laboratories perform cryoglobulin evaluation, there are widespread differences in the methodology used and the care with which this is carried out and this leads to considerable intralaboratory and interlaboratory variability. The most common sources of error are false-negative results due to loss of cryoprecipitate during transport and storage. Better standardization is needed to avoid missed diagnoses and improve the comparability of results. Laboratories should ensure that sample temperature is maintained at 37 degrees C until the serum is separated. In this article, we briefly review the classification and clinical features of cryoglobulins and suggest best practice guidelines for laboratory detection and identification of cryoglobulins.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 50 条
  • [1] Cryoglobulin evaluation: best practice? (vol 47, pg 8, 2010)
    Lock, Robert J.
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 185 - 185
  • [2] Cryoglobulin evaluation: best practice? (vol 47, pg 8, 2010)
    Sargur, Ravishankar
    White, Peter
    Egner, William
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2010, 47 : 185 - 185
  • [3] Best Practices for Best Practice Alerts: Evaluation of a Best Practice Alert to Detect Chronic Glucocorticoid Use
    Zhang, Mingyuan
    Staes, Catherine
    Kapp, Lara
    Miller, Karla L.
    [J]. ARTHRITIS & RHEUMATOLOGY, 2014, 66 : S1009 - S1010
  • [4] Evaluation of a preparative method for cryoglobulin characterization
    Passerini, Gabriella
    Trbos, Mladen
    Motta, Andrea
    Locatelli, Massimo
    Dorigatti, Fernanda
    [J]. BIOCHIMICA CLINICA, 2008, 32 (04) : 269 - 272
  • [5] Application and evaluation of the best practice guideline: Breastfeeding
    Del Rio-Martinez, Patricia
    Lopez-Garcia, Maribel
    Nieto-Martinez, Cristina
    Angeles Cabrera-Cabrera, Ma
    David Harillo-Acevedo, F.
    Mengibar-Carrillo, Aurora
    Gonzalez-Gallego, Maria
    Angeles Maestre-Garcia, Ma
    [J]. ENFERMERIA CLINICA, 2020, 30 (03): : 168 - 175
  • [6] A review of the best practice in traffic calming evaluation
    Ambros, Jiri
    Tomesova, Lenka
    Jurewicz, Chris
    Valentova, Veronika
    [J]. ACCIDENT ANALYSIS AND PREVENTION, 2023, 189
  • [7] Ensuring best practice in genomics education and evaluation
    Gaff, Clara
    [J]. EUROPEAN JOURNAL OF HUMAN GENETICS, 2023, 31 : 81 - 82
  • [8] Standards for best practice in vocational evaluation and assessment
    Schuster, D
    Sitlington, PL
    [J]. EIGHTH NATIONAL FORUM ON ISSUES IN VOCATIONAL ASSESSMENT: THE ISSUES PAPERS, 1997, : 1 - 3
  • [9] Evaluation Ethics for Best Practice: Cases and Commentaries
    MacLean, Sarah
    [J]. DRUG AND ALCOHOL REVIEW, 2009, 28 (03) : 333 - 334
  • [10] Evaluation and application of best practice in analytical method validation
    Shabir, Ghulam A.
    Lough, W. John
    Arain, Shafique A.
    Bradshaw, Tony K.
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2007, 30 (03) : 311 - 333