SHEAR RESISTANCE OF STIFFENED ANGLE SHEAR CONNECTOR CONSIDERING ELEVATED TEMPERATURE EFFECT

被引:0
|
作者
Nouri, Karim [1 ]
Sulong, N. H. Ramli [1 ]
Shariati, Mahdi [1 ]
机构
[1] Univ Malaya, Fac Engn, Dept Civil Engn, Kuala Lumpur 50603, Malaysia
关键词
Shear connector; Stiffened angle connector; High temperature; Shear resistance; Push-out test; HIGH-STRENGTH CONCRETE; BEHAVIOR; CHANNEL; STUDS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study was performed to investigate the behaviour of a newly proposed shear connector i.e. stiffened angle shear connector at elevated temperature. This paper describes a finding on shear resistance of the stiffened angle shear connectors subjected to isothermal fire loading. Eight push-out specimens were tested covering various geometries of stiffened angle shear connector. The specimens were first heated from a room temperature up to a target temperature followed by incremental monotonic loading in order to assess the connector shear resistance at high temperatures. A comparison was done between the behaviour at ambient temperature and high temperature. The results show the stiffened angle shear connector exhibited high shear resistance and the failure mode was governed by connector fracture.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Finite Element Analysis of Novel Stiffened Angle Shear Connectors at Ambient and Elevated Temperature
    Nouri, Karim
    Ramli Sulong, Nor Hafizah
    Ibrahim, Zainah
    Bazzaz, Mohammad
    Ali, H. Elhosiny
    SUSTAINABILITY, 2023, 15 (01)
  • [2] BEHAVIOUR OF NOVEL STIFFENED ANGLE SHEAR CONNECTORS AT AMBIENT AND ELEVATED TEMPERATURES
    Nouri, Karim
    Sulong, N. H. Ramli
    Ibrahim, Zainah
    Shariati, Mahdi
    ADVANCED STEEL CONSTRUCTION, 2021, 17 (01): : 28 - 38
  • [3] Shear resistance of stiffened steel corrugated shear walls
    Tong, Jing-Zhong
    Guo, Yan-Lin
    THIN-WALLED STRUCTURES, 2018, 127 : 76 - 89
  • [4] Development of Shear Resistance Formula for the Y-Type Perfobond Rib Shear Connector Considering Probabilistic Characteristics
    Kim, Sang-Hyo
    Batbold, Tuvshintur
    Shah, Syed Haider Ali
    Yoon, Suro
    Han, Oneil
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [5] Effect of shear connector spacing and layout on the shear connector capacity in composite beams
    Qureshi, Jawed
    Lam, Dennis
    Ye, Jianqiao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (04) : 706 - 719
  • [6] Shear resistance of sandwich panel connection at elevated temperature
    Cabova, Kamila
    Garifullin, Marsel
    Mofrad, Ashkan Shoushtarian
    Wald, Frantisek
    Mela, Kristo
    Ciupack, Yvonne
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2022, 13 (02) : 162 - 170
  • [7] Influence of coarse aggregates on the shear resistance of perfobond rib shear connector
    Manabe, Yota
    Fujiyama, Chikako
    Kisaku, Tomoaki
    Shionaga, Riyousuke
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS, 2014, 95 : 454 - 464
  • [8] Experimental and Numerical Study on Shear Resistance of Notched Perfobond Shear Connector
    Zheng, Shuangjie
    Liu, Yuqing
    Liu, Yangqing
    Zhao, Chen
    MATERIALS, 2019, 12 (03)
  • [9] An investigation on the behavior of stiffened coupled shear walls considering axial force effect
    Hadidi, Ali
    Azar, Bahman Farahmand
    Khosravi, Hossein
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2013, 22 (18): : 1390 - 1403
  • [10] Shear strength of stiffened steel shear walls with considering the gravity load effect through a three-segment distribution
    Li, Jie
    Lv, Jia-Qi
    Sivakumar, Vinu
    Chen, Yu
    Huang, Xin
    Lv, Yang
    Chouw, Nawawi
    STRUCTURES, 2021, 29 : 265 - 272