Computerized algorithm for baseline estimation of fetal heart rate

被引:17
|
作者
Jiménez, L [1 ]
González, R [1 ]
Gaitán, MJ [1 ]
Carrasco, S [1 ]
Vargas, C [1 ]
机构
[1] Univ Autonoma Metropolitana Iztapalapa, Mexico City 09340, DF, Mexico
来源
关键词
D O I
10.1109/CIC.2002.1166813
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
On the present work, we propose an algorithm that after unstable segments identification by the first derivative estimates the baseline of antepartum fetal cardiotachograms. Therefore, 50 records 5 minutes long, derived from abdominal ECG, were processed according to the methods of Dawes, Mantel, and our proposal. Besides visual analysis, statistical differences among methods were established More appropriate visual fits of the baseline were gotten by our proposal (76%) than Mantel (22%) and Dawes (2016). Since lower mean baseline was computed from Mantel (137.8+/-8.4 bpm) than from Dawes (140.4+/-8.4 bpm) and our proposal (140.0+/-8.4 bpm), different account for accelerations and decelerations were also found Our proposal showed advantages to estimate the baseline of cardiotachograms as it was properly adjusted at the beginning of the traces, depended of only 15 seconds of valid segments and corresponded more closely to the visual baseline.
引用
收藏
页码:477 / 480
页数:4
相关论文
共 50 条
  • [1] Computerized Algorithm for Fetal Heart Rate Baseline and Baseline Variability Estimation based on Distance Between Signal Average and α Value
    Nidhal, Shahad
    Ali, M. A. Mohd
    Zaidan, A. A.
    Zaidan, B. B.
    Najah, Hind
    [J]. INTERNATIONAL JOURNAL OF PHARMACOLOGY, 2011, 7 (02) : 228 - 237
  • [2] A novel cardiotocography fetal heart rate baseline estimation algorithm
    Nidhal, Shahad
    Ali, M. A. Mohd.
    Najah, Hind
    [J]. SCIENTIFIC RESEARCH AND ESSAYS, 2010, 5 (24): : 4002 - 4010
  • [3] Computerized estimation of the baseline fetal heart rate in labour: the low frequency line
    Bernardes, J
    Costa-Pereira, A
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1998, 105 (10): : 1128 - 1128
  • [4] Computerized Fetal Heart Rate Baseline Estimation Based on Number and Continuity of Occurrences
    Krupa, B. Niranjana
    Ali, M. A. Mohd.
    Zahedi, E.
    [J]. 4TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2008, VOLS 1 AND 2, 2008, 21 (1-2): : 162 - +
  • [5] Computerized estimation of the baseline fetal heart rate in labour: the low frequency line - Reply
    Mongelli, M
    Sahota, D
    Chung, TKH
    Chang, AMZ
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1998, 105 (10): : 1129 - 1129
  • [6] A more objective fetal heart rate baseline estimation
    Bernardes, J
    CostaPereira, A
    vanGeijn, H
    PereiraLeite, L
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1996, 103 (07): : 714 - 715
  • [7] Fetal heart rate baseline estimation with analysis of fetal movement signal
    Lu, Yaosheng
    Li, Xiaodong
    Wei, Shouyi
    Liu, Xiaolei
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 3763 - 3769
  • [8] Can the reproducibility of fetal heart rate baseline estimation be improved?
    Ayres-de-Campos, D
    Bernardes, J
    Marsal, K
    Nickelsen, C
    Makarainen, L
    Banfield, P
    Xavier, P
    Campos, I
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 112 (01) : 49 - 54
  • [9] Validation of a computerized algorithm to quantify fetal heart rate deceleration area
    Gyllencreutz, Erika
    Lu, Ke
    Lindecrantz, Kaj
    Lindqvist, Pelle G.
    Nordstrom, Lennart
    Holzmann, Malin
    Abtahi, Farhad
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2018, 97 (09) : 1137 - 1147
  • [10] Heart rate estimation and validation algorithm for fetal phonocardiography
    Bhaskaran, Amrutha
    Kumar, Sidhesh J.
    George, Shirley
    Arora, Manish
    [J]. PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)